Available on request

Pepperl Fuchs NJ5-30GK-S1N

MPN: NJ5-30GK-S1N · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryInductive Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can NJ5-30GK-S1N be shipped?

NJ5-30GK-S1N is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NJ5-30GK-S1N in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NJ5-30GK-S1N and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ5-30GK-S1N, subject to availability and destination.

Inductive sensor. Extended temperature range, Suitable for 2:1 technology, Switching function: Normally open (NO), Output type: NAMUR with safety function, Installation: flush in mild steel, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X. Switching function: Normally open (NO). Output type: NAMUR with safety function. Rated operating distance: 5 mm. Installation: flush in mild steel. Assured operating distance: 0 ... 4.05 mm. Reduction factor rAl: 1. Reduction factor rCu: 1. Reduction factor r304: 0. Safety Integrity Level (SIL): up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 150 Hz. Suitable for 2:1 technology: yes , with reverse polarity protection diode. Current consumption: . Measuring plate not detected≤ 1 mAMeasuring plate detected≥ 3 mA: . Measuring plate not detected: ≤ 1 mA. Measuring plate detected: ≥ 3 mA. Safety Integrity Level (SIL): SIL 3. MTTFd: 11850 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Ga: IECEx PTB 11.0092X. Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Gc (ec): IECEx TUR 21.0017X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Dc (tc): IECEx TUR 21.0018X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X: . Equipment protection level Ga: PTB 00 ATEX 2049 X. Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Gc (ec): TÜV 20 ATEX 8523 X. Equipment protection level Da: PTB 00 ATEX 2049 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8524 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0454. CCC approval: . Hazardous Location2020322315002308 2024322315005947 2024322315005860: . Hazardous Location: 2020322315002308 2024322315005947 2024322315005860. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: cable. Housing material: Crastin (PBT), black. Sensing face: Crastin (PBT), black. Degree of protection: IP68. Cable: . Cable diameter6.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.75 mm2LengthL2 m: . Cable diameter: 6.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: silicone. Core cross section: 0.75 mm2. Length: 2 m. Dimensions: . Length40 mmDiameter30 mm: . Length: 40 mm. Diameter: 30 mm. Note: only for non-ferrous metal. Scope of delivery: Supplied with 2 nuts. Use in the hazardous area: see instruction manuals

Specifications

General specifications

Switching functionNormally open (NO)
Output typeNAMUR with safety function
Rated operating distance5 mm sn
Installationflush in mild steel
Assured operating distance0 ... 4.05 mm sa
Reduction factor rAl1
Reduction factor rCu1
Reduction factor r3040
Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 150 Hz f
Suitable for 2:1 technologyyes , with reverse polarity protection diode
Current consumption
Measuring plate not detected≤ 1 mAMeasuring plate detected≥ 3 mA Measuring plate not detected
Measuring plate not detected≤ 1 mA
Measuring plate detected≥ 3 mA

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3
MTTFd11850 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
StandardsEN IEC 60947-5-2 Standards
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X Equipment protection level Ga
Equipment protection level GaIECEx PTB 11.0092X
Equipment protection level GbIECEx PTB 11.0092X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level DaIECEx PTB 11.0092X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level MbIECEx PTB 11.0092X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X Equipment protection level Ga
Equipment protection level GaPTB 00 ATEX 2049 X
Equipment protection level GbPTB 00 ATEX 2049 X
Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X
Equipment protection level DaPTB 00 ATEX 2049 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454 Ordinary Location
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0454
CCC approval
Hazardous Location2020322315002308 2024322315005947 2024322315005860 Hazardous Location
Hazardous Location2020322315002308 2024322315005947 2024322315005860

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)

Mechanical specifications

Connection typecable
Housing materialCrastin (PBT), black
Sensing faceCrastin (PBT), black
Degree of protectionIP68
Cable
Cable diameter6.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.75 mm2LengthL2 m Cable diameter
Cable diameter6.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Materialsilicone
Core cross section0.75 mm2
Length2 m L
Dimensions
Length40 mmDiameter30 mm Length
Length40 mm
Diameter30 mm
Noteonly for non-ferrous metal

General information

Scope of deliverySupplied with 2 nuts
Use in the hazardous areasee instruction manuals
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs NJ5-18GM50-E3Available on requestPepperl Fuchs NJ5-18GM50-E3
MPN: NJ5-18GM50-E3 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-18GM50-E3-10MAvailable on requestPepperl Fuchs NJ5-18GM50-E3-10M
MPN: NJ5-18GM50-E3-10M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-18GM50-E3-5MAvailable on requestPepperl Fuchs NJ5-18GM50-E3-5M
MPN: NJ5-18GM50-E3-5M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-18GM50-E3-V1Available on requestPepperl Fuchs NJ5-18GM50-E3-V1
MPN: NJ5-18GM50-E3-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-30GK-S1N-10MAvailable on requestPepperl Fuchs NJ5-30GK-S1N-10M
MPN: NJ5-30GK-S1N-10M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-30GK-S1N-15MAvailable on requestPepperl Fuchs NJ5-30GK-S1N-15M
MPN: NJ5-30GK-S1N-15M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ5-30GK-S1N-5MAvailable on requestPepperl Fuchs NJ5-30GK-S1N-5M
MPN: NJ5-30GK-S1N-5M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ50-FP-A-P1Available on requestPepperl Fuchs NJ50-FP-A-P1
MPN: NJ50-FP-A-P1 · Pepperl Fuchs
Price on request
Request a quote