Pepperl Fuchs NJ5-18GK-SN
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NJ5-18GK-SN be shipped?
NJ5-18GK-SN is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NJ5-18GK-SN in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NJ5-18GK-SN and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ5-18GK-SN, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Rated operating distance: 5 mm. Installation: flush. Assured operating distance: 0 ... 4.05 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Safety Integrity Level (SIL): up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 500 Hz. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 3. MTTFd: 11850 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Ga: IECEx PTB 11.0092X. Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Gc (ec): IECEx TUR 21.0017X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Dc (tc): IECEx TUR 21.0018X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X: . Equipment protection level Ga: PTB 00 ATEX 2049 X. Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Gc (ec): TÜV 20 ATEX 8523 X. Equipment protection level Da: PTB 00 ATEX 2049 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8524 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0454. CCC approval: . Hazardous Location2020322315002308 2024322315005947 2024322315005860: . Hazardous Location: 2020322315002308 2024322315005947 2024322315005860. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: cable. Housing material: Crastin (PBT), black. Sensing face: Crastin (PBT), black. Degree of protection: IP68. Cable: . Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.75 mm2LengthL2 m: . Cable diameter: 6 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: silicone. Core cross section: 0.75 mm2. Length: 2 m. Dimensions: . Length39 mmDiameter18 mm: . Length: 39 mm. Diameter: 18 mm. Scope of delivery: Supplied with 2 nuts. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR with safety function |
| Rated operating distance | 5 mm sn |
| Installation | flush |
| Assured operating distance | 0 ... 4.05 mm sa |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 500 Hz f |
| Current consumption | |
| Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| MTTFd | 11850 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Gc (ec) | IECEx TUR 21.0017X |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0018X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| ATEX approval | |
| Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X | Equipment protection level Ga |
| Equipment protection level Ga | PTB 00 ATEX 2049 X |
| Equipment protection level Gb | PTB 00 ATEX 2049 X |
| Equipment protection level Gc (ec) | TÜV 20 ATEX 8523 X |
| Equipment protection level Da | PTB 00 ATEX 2049 X |
| Equipment protection level Dc (tc) | TÜV 20 ATEX 8524 X |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0454 |
| CCC approval | |
| Hazardous Location2020322315002308 2024322315005947 2024322315005860 | Hazardous Location |
| Hazardous Location | 2020322315002308 2024322315005947 2024322315005860 |
Ambient conditions
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | Crastin (PBT), black |
| Sensing face | Crastin (PBT), black |
| Degree of protection | IP68 |
| Cable | |
| Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.75 mm2LengthL2 m | Cable diameter |
| Cable diameter | 6 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | silicone |
| Core cross section | 0.75 mm2 |
| Length | 2 m L |
| Dimensions | |
| Length39 mmDiameter18 mm | Length |
| Length | 39 mm |
| Diameter | 18 mm |
General information
| Scope of delivery | Supplied with 2 nuts |
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G


