Pepperl Fuchs NJ2-12GK-SN-0,3M
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NJ2-12GK-SN-0,3M be shipped?
NJ2-12GK-SN-0,3M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NJ2-12GK-SN-0,3M in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NJ2-12GK-SN-0,3M and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ2-12GK-SN-0,3M, subject to availability and destination.
Inductive sensor. Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 5 ... 25 V <sup>1)</sup>, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Rated operating distance: 2 mm. Installation: flush. Assured operating distance: 0 ... 1.62 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Safety Integrity Level (SIL): up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 5 ... 25 V 1). Switching frequency: 0 ... 2000 Hz. Suitable for 2:1 technology: yes , with reverse polarity protection diode. Current consumption: . Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage: . Measuring plate not detected: ≥ 3 mA at nominal voltage. Measuring plate detected: ≤ 1 mA at nominal voltage. Safety Integrity Level (SIL): SIL 3. MTTFd: 7660 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Ga: IECEx PTB 11.0092X. Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X: . Equipment protection level Ga: PTB 00 ATEX 2049 X. Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Da: PTB 00 ATEX 2049 X. UL approval: cULus Listed, General Purpose. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0454. CCC approval: . Hazardous Location2020322315002308: . Hazardous Location: 2020322315002308. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: cable. Housing material: PP. Sensing face: PP. Degree of protection: IP68. Cable: . Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.34 mm2LengthL0.3 m: . Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: silicone. Core cross section: 0.34 mm2. Length: 0.3 m. Dimensions: . Length34 mmDiameter12 mm: . Length: 34 mm. Diameter: 12 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR with safety function |
| Rated operating distance | 2 mm sn |
| Installation | flush |
| Assured operating distance | 0 ... 1.62 mm sa |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Operating voltage | 5 ... 25 V 1) UB |
| Switching frequency | 0 ... 2000 Hz f |
| Suitable for 2:1 technology | yes , with reverse polarity protection diode |
| Current consumption | |
| Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA at nominal voltage |
| Measuring plate detected | ≤ 1 mA at nominal voltage |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| MTTFd | 7660 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level MbIECEx PTB 11.0092X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| ATEX approval | |
| Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level DaPTB 00 ATEX 2049 X | Equipment protection level Ga |
| Equipment protection level Ga | PTB 00 ATEX 2049 X |
| Equipment protection level Gb | PTB 00 ATEX 2049 X |
| Equipment protection level Da | PTB 00 ATEX 2049 X |
| UL approval | cULus Listed, General Purpose |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0454 |
| CCC approval | |
| Hazardous Location2020322315002308 | Hazardous Location |
| Hazardous Location | 2020322315002308 |
Ambient conditions
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | PP |
| Sensing face | PP |
| Degree of protection | IP68 |
| Cable | |
| Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.34 mm2LengthL0.3 m | Cable diameter |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | silicone |
| Core cross section | 0.34 mm2 |
| Length | 0.3 m L |
| Dimensions | |
| Length34 mmDiameter12 mm | Length |
| Length | 34 mm |
| Diameter | 12 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G