Available on request

Pepperl Fuchs NJ2-11-SN

MPN: NJ2-11-SN · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryInductive Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can NJ2-11-SN be shipped?

NJ2-11-SN is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NJ2-11-SN in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NJ2-11-SN and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ2-11-SN, subject to availability and destination.

Inductive sensor. Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Construction type: Cylindrical, flat, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X. Switching function: Normally closed (NC). Output type: NAMUR with safety function. Rated operating distance: 2 mm. Installation: flush. Assured operating distance: 0 ... 1.62 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Safety Integrity Level (SIL): up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 3000 Hz. Suitable for 2:1 technology: yes , with reverse polarity protection diode. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 3. MTTFd: 10660 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X: . Equipment protection level Ga: IECEx PTB 11.0092X. Equipment protection level Gb: IECEx PTB 11.0092X. Equipment protection level Gc (ec): IECEx TUR 21.0017X. Equipment protection level Da: IECEx PTB 11.0092X. Equipment protection level Dc (tc): IECEx TUR 21.0018X. Equipment protection level Mb: IECEx PTB 11.0092X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X: . Equipment protection level Ga: PTB 00 ATEX 2049 X. Equipment protection level Gb: PTB 00 ATEX 2049 X. Equipment protection level Gc (ec): TÜV 20 ATEX 8523 X. Equipment protection level Da: PTB 00 ATEX 2049 X. Equipment protection level Dc (tc): TÜV 20 ATEX 8524 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0454. CCC approval: . Hazardous Location2020322315002308 2024322315005947 2024322315005860: . Hazardous Location: 2020322315002308 2024322315005947 2024322315005860. TIIS approval: on request. Ambient temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: cable. Housing material: Valox (PBT) , black. Sensing face: Valox (PBT) , black. Degree of protection: IP68. Cable: . Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.34 mm2LengthL2 m: . Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: silicone. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Length31 mmDiameter11 mm: . Length: 31 mm. Diameter: 11 mm. Use in the hazardous area: see instruction manuals

Specifications

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR with safety function
Rated operating distance2 mm sn
Installationflush
Assured operating distance0 ... 1.62 mm sa
Reduction factor rAl0.4
Reduction factor rCu0.3
Reduction factor r3040.85
Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 3000 Hz f
Suitable for 2:1 technologyyes , with reverse polarity protection diode
Current consumption
Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA Measuring plate not detected
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3
MTTFd10660 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 NAMUR
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0092XEquipment protection level GbIECEx PTB 11.0092XEquipment protection level Gc (ec)IECEx TUR 21.0017XEquipment protection level DaIECEx PTB 11.0092XEquipment protection level Dc (tc)IECEx TUR 21.0018XEquipment protection level MbIECEx PTB 11.0092X Equipment protection level Ga
Equipment protection level GaIECEx PTB 11.0092X
Equipment protection level GbIECEx PTB 11.0092X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level DaIECEx PTB 11.0092X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level MbIECEx PTB 11.0092X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2049 XEquipment protection level GbPTB 00 ATEX 2049 XEquipment protection level Gc (ec)TÜV 20 ATEX 8523 XEquipment protection level DaPTB 00 ATEX 2049 XEquipment protection level Dc (tc)TÜV 20 ATEX 8524 X Equipment protection level Ga
Equipment protection level GaPTB 00 ATEX 2049 X
Equipment protection level GbPTB 00 ATEX 2049 X
Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X
Equipment protection level DaPTB 00 ATEX 2049 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0454 Ordinary Location
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0454
CCC approval
Hazardous Location2020322315002308 2024322315005947 2024322315005860 Hazardous Location
Hazardous Location2020322315002308 2024322315005947 2024322315005860
TIIS approvalon request

Ambient conditions

Ambient temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection typecable
Housing materialValox (PBT) , black
Sensing faceValox (PBT) , black
Degree of protectionIP68
Cable
Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialsiliconeCore cross section0.34 mm2LengthL2 m Cable diameter
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Materialsilicone
Core cross section0.34 mm2
Length2 m L
Dimensions
Length31 mmDiameter11 mm Length
Length31 mm
Diameter11 mm

General information

Use in the hazardous areasee instruction manuals
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote