Quick facts

AvailabilityConfirmed on request
CategoryInductive Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can NJ15-M1K-N-V1 be shipped?

NJ15-M1K-N-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NJ15-M1K-N-V1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NJ15-M1K-N-V1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ15-M1K-N-V1, subject to availability and destination.

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Construction type: Rectangular, Series: VariKont M ® , Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Ga: PTB 00 ATEX 2032 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 15 mm. Installation: non-flush. Assured operating distance: 0 ... 12.15 mm. Actual operating distance: 13.5 ... 16.5 mm typ.. Reduction factor rAl: 0.45. Reduction factor rCu: 0.4. Reduction factor r304: 0.8. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 100 Hz. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: LED, yellow. MTTFd: 2424 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2012StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2012. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Ga: IECEx PTB 11.0021X. Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X: . Equipment protection level Ga: PTB 00 ATEX 2032 X. Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0451. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: Connector plug. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Dimensions: . Height30 mmWidth30 mmLength91 mm: . Height: 30 mm. Width: 30 mm. Length: 91 mm. Use in the hazardous area: see instruction manuals

Specifications

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm sn
Installationnon-flush
Assured operating distance0 ... 12.15 mm sa
Actual operating distance13.5 ... 16.5 mm typ. sr
Reduction factor rAl0.45
Reduction factor rCu0.4
Reduction factor r3040.8
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 100 Hz f
Current consumption
Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA Measuring plate not detected
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Switching state indicatorLED, yellow

Functional safety related parameters

MTTFd2424 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2012StandardsEN IEC 60947-5-2 NAMUR
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2012
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X Equipment protection level Ga
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Ga
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
UL approvalcULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451 Ordinary Location
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CML approvalon request
ANZEx19.3001X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)

Mechanical specifications

Connection typeConnector plug
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Connector
ThreadingM12 x 1Number of pins4 Threading
ThreadingM12 x 1
Number of pins4
Dimensions
Height30 mmWidth30 mmLength91 mm Height
Height30 mm
Width30 mm
Length91 mm

General information

Use in the hazardous areasee instruction manuals
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs NJ15-M1-E2-V1-Y222496Available on requestPepperl Fuchs NJ15-M1-E2-V1-Y222496
MPN: NJ15-M1-E2-V1-Y222496 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-M1K-A2Available on requestPepperl Fuchs NJ15-M1K-A2
MPN: NJ15-M1K-A2 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-M1K-A2-V1Available on requestPepperl Fuchs NJ15-M1K-A2-V1
MPN: NJ15-M1K-A2-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-M1K-NAvailable on requestPepperl Fuchs NJ15-M1K-N
MPN: NJ15-M1K-N · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ1.5-PD-E02-1.250-V95Available on requestPepperl Fuchs NJ1.5-PD-E02-1.250-V95
MPN: NJ1.5-PD-E02-1.250-V95 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ1.5-PD-US-1.250-V93Available on requestPepperl Fuchs NJ1.5-PD-US-1.250-V93
MPN: NJ1.5-PD-US-1.250-V93 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15+U1+DW1-1Available on requestPepperl Fuchs NJ15+U1+DW1-1
MPN: NJ15+U1+DW1-1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15+U1+DW1-10Available on requestPepperl Fuchs NJ15+U1+DW1-10
MPN: NJ15+U1+DW1-10 · Pepperl Fuchs
Price on request
Request a quote