Available on request

Pepperl Fuchs NJ15-30GK-N-10M

MPN: NJ15-30GK-N-10M · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryInductive Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can NJ15-30GK-N-10M be shipped?

NJ15-30GK-N-10M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NJ15-30GK-N-10M in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NJ15-30GK-N-10M and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NJ15-30GK-N-10M, subject to availability and destination.

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X, Equipment protection level Gb: PTB 00 ATEX 2048 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 15 mm. Installation: non-flush. Assured operating distance: 0 ... 12.15 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 100 Hz. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 2. MTTFd: 4560 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X: . Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. CCC approval: . Hazardous Location2020322315002255: . Hazardous Location: 2020322315002255. CML approval: on request. ANZEx: 18.3018X. KCC approval: . Hazardous Location19-AV4BO-0227: . Hazardous Location: 19-AV4BO-0227. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP66 / IP68. Cable: . Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.75 mm2LengthL10 m: . Cable diameter: 6 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.75 mm2. Length: 10 m. Dimensions: . Length40 mmDiameter30 mm: . Length: 40 mm. Diameter: 30 mm. Scope of delivery: Supplied with 2 nuts. Use in the hazardous area: see instruction manuals

Specifications

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm sn
Installationnon-flush
Assured operating distance0 ... 12.15 mm sa
Reduction factor rAl0.4
Reduction factor rCu0.3
Reduction factor r3040.85
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 100 Hz f
Current consumption
Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA Measuring plate not detected
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
MTTFd4560 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 NAMUR
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X Equipment protection level Gb
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X Equipment protection level Gb
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
CCC approval
Hazardous Location2020322315002255 Hazardous Location
Hazardous Location2020322315002255
CML approvalon request
ANZEx18.3018X
KCC approval
Hazardous Location19-AV4BO-0227 Hazardous Location
Hazardous Location19-AV4BO-0227

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)

Mechanical specifications

Connection typecable
Housing materialPBT
Sensing facePBT
Degree of protectionIP66 / IP68
Cable
Cable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.75 mm2LengthL10 m Cable diameter
Cable diameter6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.75 mm2
Length10 m L
Dimensions
Length40 mmDiameter30 mm Length
Length40 mm
Diameter30 mm

General information

Scope of deliverySupplied with 2 nuts
Use in the hazardous areasee instruction manuals
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs NJ1,5-18GM-N-D-V1Available on requestPepperl Fuchs NJ1,5-18GM-N-D-V1
MPN: NJ1,5-18GM-N-D-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ1,5-18GM-N-D-V1-Y29033Available on requestPepperl Fuchs NJ1,5-18GM-N-D-V1-Y29033
MPN: NJ1,5-18GM-N-D-V1-Y29033 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-E2-T-5MAvailable on requestPepperl Fuchs NJ15-30GK-E2-T-5M
MPN: NJ15-30GK-E2-T-5M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-NAvailable on requestPepperl Fuchs NJ15-30GK-N
MPN: NJ15-30GK-N · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-N-150Available on requestPepperl Fuchs NJ15-30GK-N-150
MPN: NJ15-30GK-N-150 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-N-150-Y38977Available on requestPepperl Fuchs NJ15-30GK-N-150-Y38977
MPN: NJ15-30GK-N-150-Y38977 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-N-20MAvailable on requestPepperl Fuchs NJ15-30GK-N-20M
MPN: NJ15-30GK-N-20M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs NJ15-30GK-N-30MAvailable on requestPepperl Fuchs NJ15-30GK-N-30M
MPN: NJ15-30GK-N-30M · Pepperl Fuchs
Price on request
Request a quote