Pepperl Fuchs NCN3-F25-N4-V1 – Inductive sensor. Extended temperature range
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NCN3-F25-N4-V1 be shipped?
NCN3-F25-N4-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NCN3-F25-N4-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NCN3-F25-N4-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NCN3-F25-N4-V1, subject to availability and destination.
Inductive sensor. Extended temperature range, Valve position detection, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 17.0021X, Equipment protection level Gb: IECEx TUN 17.0021X, Equipment protection level Da: IECEx TUN 17.0021X, Equipment protection level Mb: IECEx TUN 17.0021X. Switching function: 2 x normally closed (NC). Output type: NAMUR. Rated operating distance: 3 mm. Installation: flush mountable. Assured operating distance: 0 ... 2.43 mm. Actual operating distance: 2.7 ... 3.3 mm typ.. Reduction factor rAl: 0.52. Reduction factor rCu: 0.43. Reduction factor r304: 0.86. Reduction factor rSt37: 1. Reduction factor rBrass: 0.54. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 1500 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Suitable for 2:1 technology: yes , Reverse polarity protection diode not required. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Time delay before availability: ≤ 1 ms. Switching state indicator: LED, yellow. MTTFd: 1010 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx TUN 17.0021XEquipment protection level GbIECEx TUN 17.0021XEquipment protection level DaIECEx TUN 17.0021XEquipment protection level MbIECEx TUN 17.0021X: . Equipment protection level Ga: IECEx TUN 17.0021X. Equipment protection level Gb: IECEx TUN 17.0021X. Equipment protection level Da: IECEx TUN 17.0021X. Equipment protection level Mb: IECEx TUN 17.0021X. ATEX approval: . Equipment protection level GaTÜV 99 ATEX 1479 XEquipment protection level GbTÜV 99 ATEX 1479 XEquipment protection level DaTÜV 99 ATEX 1479 X: . Equipment protection level Ga: TÜV 99 ATEX 1479 X. Equipment protection level Gb: TÜV 99 ATEX 1479 X. Equipment protection level Da: TÜV 99 ATEX 1479 X. UL approval: cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0456: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0456. CCC approval: . Hazardous Location2020322315002262: . Hazardous Location: 2020322315002262. NEPSI approval: . NEPSI certificateGYJ19.1410X: . NEPSI certificate: GYJ19.1410X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: Connector plug. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Mass: 45 g. Tightening torque, fastening screws: M5 x 25 : ≤ 2.7 Nm. Dimensions: . Height20 mmWidth52 mmLength52 mm: . Height: 20 mm. Width: 52 mm. Length: 52 mm. Note: Mounted on mechanical drive. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm sn |
| Installation | flush mountable |
| Assured operating distance | 0 ... 2.43 mm sa |
| Actual operating distance | 2.7 ... 3.3 mm typ. sr |
| Reduction factor rAl | 0.52 |
| Reduction factor rCu | 0.43 |
| Reduction factor r304 | 0.86 |
| Reduction factor rSt37 | 1 |
| Reduction factor rBrass | 0.54 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Switching frequency | 0 ... 1500 Hz f |
| Hysteresis | typ. 5 % H |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Time delay before availability | ≤ 1 ms tv |
| Switching state indicator | LED, yellow |
Functional safety related parameters
| MTTFd | 1010 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GaIECEx TUN 17.0021XEquipment protection level GbIECEx TUN 17.0021XEquipment protection level DaIECEx TUN 17.0021XEquipment protection level MbIECEx TUN 17.0021X | Equipment protection level Ga |
| Equipment protection level Ga | IECEx TUN 17.0021X |
| Equipment protection level Gb | IECEx TUN 17.0021X |
| Equipment protection level Da | IECEx TUN 17.0021X |
| Equipment protection level Mb | IECEx TUN 17.0021X |
| ATEX approval | |
| Equipment protection level GaTÜV 99 ATEX 1479 XEquipment protection level GbTÜV 99 ATEX 1479 XEquipment protection level DaTÜV 99 ATEX 1479 X | Equipment protection level Ga |
| Equipment protection level Ga | TÜV 99 ATEX 1479 X |
| Equipment protection level Gb | TÜV 99 ATEX 1479 X |
| Equipment protection level Da | TÜV 99 ATEX 1479 X |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0456 | Ordinary Location |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0456 |
| CCC approval | |
| Hazardous Location2020322315002262 | Hazardous Location |
| Hazardous Location | 2020322315002262 |
| NEPSI approval | |
| NEPSI certificateGYJ19.1410X | NEPSI certificate |
| NEPSI certificate | GYJ19.1410X |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications
| Connection type | Connector plug |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Connector | |
| ThreadingM12 x 1Number of pins4 | Threading |
| Threading | M12 x 1 |
| Number of pins | 4 |
| Mass | 45 g |
| Tightening torque, fastening screws | M5 x 25 : ≤ 2.7 Nm |
| Dimensions | |
| Height20 mmWidth52 mmLength52 mm | Height |
| Height | 20 mm |
| Width | 52 mm |
| Length | 52 mm |
| Note | Mounted on mechanical drive |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NCN25-30GM50-Z4-V1 – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NCN25-30GM50-Z5 – Inductive sensor. Switching function: Normally closed (NC)
Available on requestPepperl Fuchs NCN3-F25-N4-0,14 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F25-N4-5M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F25F-N4-V1 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F25F-N4-Y41364 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F25F-N4-Y47292 – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NCN3-F31-B3-V1-K – Inductive sensor. Valve position detection

