Pepperl Fuchs NBB8-F33-E3
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NBB8-F33-E3 be shipped?
NBB8-F33-E3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NBB8-F33-E3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NBB8-F33-E3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NBB8-F33-E3, subject to availability and destination.
Inductive sensor. Switching function: Normally closed (NC), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 60 V DC, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67, Material: PVC. Switching function: Normally closed (NC). Output type: PNP. Rated operating distance: 8 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 6.48 mm. Reduction factor rAl: 0.3. Reduction factor rCu: 0.2. Reduction factor r304: 0.6. Output type: 3-wire. Operating voltage: 10 ... 60 V DC. Switching frequency: 0 ... 350 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 3 V. Operating current: 0 ... 200 mA. Off-state current: 0 ... 0.1 mA. No-load supply current: ≤ 10 mA. Time delay before availability: ≤ 50 ms. Switching state indicator: LED yellow. MTTFd: 1182 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -35 ... 70 °C (-31 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores3Core cross section0.34 mm2LengthL2 m: . Wire end ferrules: yes. Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Color: grey. Number of cores: 3. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Height10 mmWidth25 mmLength50 mm: . Height: 10 mm. Width: 25 mm. Length: 50 mm. Tightening torque: ≤ 5 Nm
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm sn |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm sa |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.6 |
| Output type | 3-wire |
Nominal ratings
| Operating voltage | 10 ... 60 V DC UB |
| Switching frequency | 0 ... 350 Hz f |
| Hysteresis | typ. 5 % H |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 3 V Ud |
| Operating current | 0 ... 200 mA IL |
| Off-state current | 0 ... 0.1 mA Ir |
| No-load supply current | ≤ 10 mA I0 |
| Time delay before availability | ≤ 50 ms tv |
| Switching state indicator | LED yellow |
Functional safety related parameters
| MTTFd | 1182 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN IEC 60947-5-2 | Standards |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA |
| CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions
| Ambient temperature | -35 ... 70 °C (-31 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores3Core cross section0.34 mm2LengthL2 m | Wire end ferrules |
| Wire end ferrules | yes |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PVC |
| Color | grey |
| Number of cores | 3 |
| Core cross section | 0.34 mm2 |
| Length | 2 m L |
| Dimensions | |
| Height10 mmWidth25 mmLength50 mm | Height |
| Height | 10 mm |
| Width | 25 mm |
| Length | 50 mm |
| Tightening torque | ≤ 5 Nm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G