Pepperl Fuchs NBB2-12GM40-Z0-V1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NBB2-12GM40-Z0-V1 be shipped?
NBB2-12GM40-Z0-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NBB2-12GM40-Z0-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NBB2-12GM40-Z0-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NBB2-12GM40-Z0-V1, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally open (NO), Output type: Two-wire, Installation: flush, Output polarity: DC, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: Connector plug, Housing material: brass, nickel-plated, Degree of protection: IP67, Threading: M12 x 1. Switching function: Normally open (NO). Output type: Two-wire. Rated operating distance: 2 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 1.62 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 1.52 mm ( -40 ... -25 °C (-40 ... -13 °F) ). Actual operating distance: 1.8 ... 2.2 mm typ.. Reduction factor rAl: 0.18. Reduction factor rCu: 0.12. Reduction factor r304: 0.67. Output type: 2-wire. Operating voltage: 5 ... 60 V. Switching frequency: 0 ... 1000 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: reverse polarity tolerant. Short-circuit protection: pulsing. Voltage drop: ≤ 5 V. Operating current: 2 ... 100 mA. Lowest operating current: 2 mA. Off-state current: 0 ... 0.5 mA typ.. Time delay before availability: ≤. Switching state indicator: Multihole-LED, yellow. MTTFd: 2250 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 100 mA. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Connection type: Connector plug. Housing material: brass, nickel-plated. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins3: . Threading: M12 x 1. Number of pins: 3. Mass: 28 g. Dimensions: . Length40 mmDiameter12 mm: . Length: 40 mm. Diameter: 12 mm
Specifications
General specifications
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 2 mm sn |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 1.52 mm ( -40 ... -25 °C (-40 ... -13 °F) ) sa |
| Actual operating distance | 1.8 ... 2.2 mm typ. sr |
| Reduction factor rAl | 0.18 |
| Reduction factor rCu | 0.12 |
| Reduction factor r304 | 0.67 |
| Output type | 2-wire |
Nominal ratings
| Operating voltage | 5 ... 60 V UB |
| Switching frequency | 0 ... 1000 Hz f |
| Hysteresis | 1 ... 10 % typ. 5 % H |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 5 V Ud |
| Operating current | 2 ... 100 mA IL |
| Lowest operating current | 2 mA Im |
| Off-state current | 0 ... 0.5 mA typ. Ir |
| Time delay before availability | ≤ tv |
| Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters
| MTTFd | 2250 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN IEC 60947-5-2 | Standards |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 100 mA |
| CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Connection type | Connector plug |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Connector | |
| ThreadingM12 x 1Number of pins3 | Threading |
| Threading | M12 x 1 |
| Number of pins | 3 |
| Mass | 28 g |
| Dimensions | |
| Length40 mmDiameter12 mm | Length |
| Length | 40 mm |
| Diameter | 12 mm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NBB2-12GM40-E3-10M
Available on requestPepperl Fuchs NBB2-12GM40-Z0
Available on requestPepperl Fuchs NBB2-12GM40-Z0-3G-3D
Available on requestPepperl Fuchs NBB2-12GM40-Z0-5M-Y87672
Available on requestPepperl Fuchs NBB2-12GM40-Z3-V1
Available on requestPepperl Fuchs NBB2-12GM50-A0
Available on requestPepperl Fuchs NBB2-12GM50-A0-V1
Available on requestPepperl Fuchs NBB2-12GM50-A2


