Available on request

Pepperl Fuchs NBB15-U2K-N0

MPN: NBB15-U2K-N0 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryInductive Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can NBB15-U2K-N0 be shipped?

NBB15-U2K-N0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NBB15-U2K-N0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NBB15-U2K-N0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NBB15-U2K-N0, subject to availability and destination.

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: <i>VariKont</i> <sup>®</sup>, Series: <i>VariKont</i> <sup>®</sup>, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Ga: PTB 00 ATEX 2032 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 15 mm. Installation: flush. Assured operating distance: 0 ... 12.15 mm. Actual operating distance: 13.5 ... 16.5 mm typ. 15 mm. Reduction factor rAl: 0.33. Reduction factor rCu: 0.31. Reduction factor r304: 0.74. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 ... 300 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: yes. Short-circuit protection: yes. Current consumption: . Measuring plate not detectedmin. 2.2 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 2.2 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: LED, yellow. MTTFd: 1660 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Ga: IECEx PTB 11.0021X. Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X: . Equipment protection level Ga: PTB 00 ATEX 2032 X. Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0451. CCC approval: . Hazardous Location2020322315002303: . Hazardous Location: 2020322315002303. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Storage temperature: -40 ... 100 °C (-40 ... 212 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2. Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2: . Minimum core cross-section: without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2. Maximum core cross-section: without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2. Housing material: PA. Sensing face: PA. Degree of protection: IP68 / IP69K. Mass: 225 g. Dimensions: . Height40 mmWidth40 mmLength118 mm: . Height: 40 mm. Width: 40 mm. Length: 118 mm. Note: Tightening torque: 1.8 Nm (housing). Use in the hazardous area: see instruction manuals

Specifications

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm sn
Installationflush
Assured operating distance0 ... 12.15 mm sa
Actual operating distance13.5 ... 16.5 mm typ. 15 mm sr
Reduction factor rAl0.33
Reduction factor rCu0.31
Reduction factor r3040.74
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 300 Hz f
Hysteresistyp. 5 % H
Reverse polarity protectionyes
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mAMeasuring plate detected≤ 1 mA Measuring plate not detected
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected≤ 1 mA
Switching state indicatorLED, yellow

Functional safety related parameters

MTTFd1660 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2 NAMUR
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X Equipment protection level Ga
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X Equipment protection level Ga
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451 Ordinary Location
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CCC approval
Hazardous Location2020322315002303 Hazardous Location
Hazardous Location2020322315002303
CML approvalon request
ANZEx19.3001X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2 Minimum core cross-section
Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPA
Sensing facePA
Degree of protectionIP68 / IP69K
Mass225 g
Dimensions
Height40 mmWidth40 mmLength118 mm Height
Height40 mm
Width40 mm
Length118 mm
NoteTightening torque: 1.8 Nm (housing)

General information

Use in the hazardous areasee instruction manuals
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote