Pepperl Fuchs NBB10-30GS50-Z4L-V1 – Inductive sensor. Switching function: Normally open (NO)
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NBB10-30GS50-Z4L-V1 be shipped?
NBB10-30GS50-Z4L-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NBB10-30GS50-Z4L-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NBB10-30GS50-Z4L-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NBB10-30GS50-Z4L-V1, subject to availability and destination.
Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire with minimum off-state current, Installation: flush, Output polarity: DC, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1. Switching function: Normally open (NO). Output type: Two-wire with minimum off-state current. Rated operating distance: 10 mm. Installation: flush. Output polarity: DC. Assured operating distance: 0 ... 8.1 mm. Actual operating distance: 9 ... 11 mm typ.. Reduction factor rAl: 0.32. Reduction factor rCu: 0.3. Reduction factor r304: 0.66. Output type: 2-wire. Operating voltage: 4 ... 30 V. Switching frequency: 0 ... 150 Hz. Hysteresis: 1 ... 10 % typ. 5 %. Reverse polarity protection: yes. Short-circuit protection: pulsing. Voltage drop: ≤ 4 V. Operating current: 2 ... 30 mA. Lowest operating current: 2 mA. Off-state current: ≤ 200 µA. Switching state indicator: Multihole-LED, yellow. MTTFd: 1536 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 30 mA. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Connection type: Connector plug. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins2: . Threading: M12 x 1. Number of pins: 2. Mass: 148 g. Dimensions: . Length66 mmDiameter30 mm: . Length: 66 mm. Diameter: 30 mm. Scope of delivery: 2 self locking nuts in scope of delivery
Specifications
General specifications
| Switching function | Normally open (NO) |
| Output type | Two-wire with minimum off-state current |
| Rated operating distance | 10 mm sn |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm sa |
| Actual operating distance | 9 ... 11 mm typ. sr |
| Reduction factor rAl | 0.32 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.66 |
| Output type | 2-wire |
Nominal ratings
| Operating voltage | 4 ... 30 V UB |
| Switching frequency | 0 ... 150 Hz f |
| Hysteresis | 1 ... 10 % typ. 5 % H |
| Reverse polarity protection | yes |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 4 V Ud |
| Operating current | 2 ... 30 mA IL |
| Lowest operating current | 2 mA Im |
| Off-state current | ≤ 200 µA Ir |
| Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters
| MTTFd | 1536 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN IEC 60947-5-2 | Standards |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 30 mA |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | Connector plug |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Connector | |
| ThreadingM12 x 1Number of pins2 | Threading |
| Threading | M12 x 1 |
| Number of pins | 2 |
| Mass | 148 g |
| Dimensions | |
| Length66 mmDiameter30 mm | Length |
| Length | 66 mm |
| Diameter | 30 mm |
General information
| Scope of delivery | 2 self locking nuts in scope of delivery |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NBB10-30GM60-AAR-900MM-4PKD – Inductive sensor. Switching function: change-over contact
Available on requestPepperl Fuchs NBB10-30GM60-AAR-Y906216 – Inductive sensor. Switching function: change-over contact
Available on requestPepperl Fuchs NBB10-30GS50-Z4L – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-30GS50-Z4L-3G-3D – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-30GS50-Z4L-V1-3G-3D – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-F17-E2 – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-F17-E2-3M-Y296087 – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-F17-E3 – Inductive sensor. Switching function: Normally closed (NC)