Pepperl Fuchs NBB10-30GK60-AR-180MM-6DT06 – Inductive sensor. Switching function: change-over contact
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NBB10-30GK60-AR-180MM-6DT06 be shipped?
NBB10-30GK60-AR-180MM-6DT06 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NBB10-30GK60-AR-180MM-6DT06 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NBB10-30GK60-AR-180MM-6DT06 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NBB10-30GK60-AR-180MM-6DT06, subject to availability and destination.
Inductive sensor. Switching function: change-over contact, Output type: relay, Installation: flush, Output polarity: DC, Output type: Relay output, Thread mold: M30, Construction type: Cylindrical, thread, Series: Relay output, Operating voltage: 10 ... 30 V DC
, Type of voltage: DC, Connection type: fixed cable with plug, Housing material: PBT, Degree of protection: IP68, Connection assembly: Connector: DT06-6S-C015
Terminal: 1062-16-0622
Wedge Lock: W6S
Connector Plug: 114017
Protective Loom: 911365. Switching function: change-over contact. Output type: relay. Rated operating distance: 10 mm. Installation: flush. Output polarity: DC. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: Relay output. Mechanical life: No load: 2 x 107 operations Full load: 1 x 105 switching cycles. Operating voltage: 10 ... 30 V DC. Switching frequency: 20 Hz. Hysteresis: approx. 10 %. Reverse polarity protection: yes. Short-circuit protection: no. Operating current: ≤ 50 mA. Switching state indicator: LED, yellow. Switching voltage: max 28 V DC. Switching current: max 6 A DC resistive load. Switching power: max 180 W. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Connection type: fixed cable with plug. Core cross section: 0.75 mm2. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Connector: . Connection assemblyConnector: DT06-6S-C015Terminal: 1062-16-0622Wedge Lock: W6SConnector Plug: 114017Protective Loom: 911365: . Connection assembly: Connector: DT06-6S-C015Terminal: 1062-16-0622Wedge Lock: W6SConnector Plug: 114017Protective Loom: 911365. Cable: . LengthLL = 170 m: L. Length: L = 170 m. Dimensions: . Length60 mmDiameter30 mm: . Length: 60 mm. Diameter: 30 mm
Specifications
General specifications
| Switching function | change-over contact |
| Output type | relay |
| Rated operating distance | 10 mm sn |
| Installation | flush |
| Output polarity | DC |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | Relay output |
| Mechanical life | No load: 2 x 107 operations Full load: 1 x 105 switching cycles |
Nominal ratings
| Operating voltage | 10 ... 30 V DC UB |
| Switching frequency | 20 Hz f |
| Hysteresis | approx. 10 % H |
| Reverse polarity protection | yes |
| Short-circuit protection | no |
| Operating current | ≤ 50 mA IL |
| Switching state indicator | LED, yellow |
Output
| Switching voltage | max 28 V DC |
| Switching current | max 6 A DC resistive load |
| Switching power | max 180 W |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN IEC 60947-5-2 | Standards |
| Standards | EN IEC 60947-5-2 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Connection type | fixed cable with plug |
| Core cross section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| Connector | |
| Connection assemblyConnector: DT06-6S-C015Terminal: 1062-16-0622Wedge Lock: W6SConnector Plug: 114017Protective Loom: 911365 | Connection assembly |
| Connection assembly | Connector: DT06-6S-C015Terminal: 1062-16-0622Wedge Lock: W6SConnector Plug: 114017Protective Loom: 911365 |
| Cable | |
| LengthLL = 170 m | L Length |
| Length | L = 170 m L |
| Dimensions | |
| Length60 mmDiameter30 mm | Length |
| Length | 60 mm |
| Diameter | 30 mm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs NBB10-30GK50-E2-10M – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-30GK50-E2-15M – Inductive sensor. Switching function: Normally open (NO)
Available on requestPepperl Fuchs NBB10-30GK50-E2-M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NBB10-30GK50-E3-M – Inductive sensor. Extended temperature range
Available on requestPepperl Fuchs NBB10-30GK60-AR-1M – Inductive sensor. Switching function: change-over contact
Available on requestPepperl Fuchs NBB10-30GK60-AR-3M – Inductive sensor. Switching function: change-over contact
Available on requestPepperl Fuchs NBB10-30GKK-WO – Inductive sensor. Switching function: Normally closed (NC)
Available on requestPepperl Fuchs NBB10-30GKK-WS – Inductive sensor. Switching function: Normally open (NO)