Pepperl Fuchs ML100-54/59/82a/103/115a/154
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Retroreflective Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can ML100-54/59/82a/103/115a/154 be shipped?
ML100-54/59/82a/103/115a/154 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ML100-54/59/82a/103/115a/154 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ML100-54/59/82a/103/115a/154 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ML100-54/59/82a/103/115a/154, subject to availability and destination.
Retroreflective sensor with polarization filter. Retroreflective sensor with polarization filter, Miniature design, Stability alarm indication, Clearly visible LEDs for Power ON, switching state and weak signal indication, No controls, Very bright, highly visible light spot. Effective detection range: 0 ... 3.5 m. Reflector distance: 0.01 ... 3.5 m. Threshold detection range: 4.5 m. Reference target: H50 reflector. Light source: LED. Light type: modulated visible red light. Polarization filter: yes. Diameter of the light spot: approx. 350 mm at a distance of 4.5 m. Opening angle: approx. 4 °. Optical face: frontal. Ambient light limit: EN 60947-5-2:2007+A1:2012. MTTFd: 860 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Operation indicator: LED green: power on. Function indicator: LED yellow: lights up when receiving the light beam ; flashes when falling short of the operating reserve; OFF when light beam is interrupted. Operating voltage: 10 ... 30 V DC. Ripple: max. 10 %. No-load supply current: < 20 mA. Stability alarm output: 1 PNP, active when falling short of operating reserve. Switching type: dark-on. Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collector. Switching voltage: max. 30 V DC. Switching current: max. 100 mA , resistive load ; stability alarm output max. 50 mA. Voltage drop: ≤ 1.5 V DC. Switching frequency: 1000 Hz. Response time: 0.5 ms. Product standard: EN 60947-5-2. UL approval: cULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -30 ... 60 °C (-22 ... 140 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP67. Connection: 300 mm fixed cable with M8 connector, 4-pin. Material: . HousingPC (Polycarbonate)Optical facePMMA: . Housing: PC (Polycarbonate). Optical face: PMMA. Mass: approx. 20 g. Tightening torque, fastening screws: 0.6 Nm. Dimensions: . Height31 mmWidth11 mmDepth20 mm: . Height: 31 mm. Width: 11 mm. Depth: 20 mm. Cable length: 0.3 m
Specifications
General specifications
| Effective detection range | 0 ... 3.5 m |
| Reflector distance | 0.01 ... 3.5 m |
| Threshold detection range | 4.5 m |
| Reference target | H50 reflector |
| Light source | LED |
| Light type | modulated visible red light |
| Polarization filter | yes |
| Diameter of the light spot | approx. 350 mm at a distance of 4.5 m |
| Opening angle | approx. 4 ° |
| Optical face | frontal |
| Ambient light limit | EN 60947-5-2:2007+A1:2012 |
Functional safety related parameters
| MTTFd | 860 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Operation indicator | LED green: power on |
| Function indicator | LED yellow: lights up when receiving the light beam ; flashes when falling short of the operating reserve; OFF when light beam is interrupted |
Electrical specifications
| Operating voltage | 10 ... 30 V DC UB |
| Ripple | max. 10 % |
| No-load supply current | < 20 mA I0 |
Output
| Stability alarm output | 1 PNP, active when falling short of operating reserve |
| Switching type | dark-on |
| Signal output | 1 PNP output, short-circuit protected, reverse polarity protected, open collector |
| Switching voltage | max. 30 V DC |
| Switching current | max. 100 mA , resistive load ; stability alarm output max. 50 mA |
| Voltage drop | ≤ 1.5 V DC Ud |
| Switching frequency | 1000 Hz f |
| Response time | 0.5 ms |
Conformity
| Product standard | EN 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | 300 mm fixed cable with M8 connector, 4-pin |
| Material | |
| HousingPC (Polycarbonate)Optical facePMMA | Housing |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
| Mass | approx. 20 g |
| Tightening torque, fastening screws | 0.6 Nm |
| Dimensions | |
| Height31 mmWidth11 mmDepth20 mm | Height |
| Height | 31 mm |
| Width | 11 mm |
| Depth | 20 mm |
| Cable length | 0.3 m |