Pepperl Fuchs LB9006C
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB9006C be shipped?
LB9006C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB9006C in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB9006C and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB9006C, subject to availability and destination.
Power supply. Power supply for 24 V, Permits vertical or horizontal mounting in Zone 2, Use three power supplies for redundancy, Galvanic isolation to mains, Voltage: 5.4 V DC +/- 5% , <BR>12 V DC + 4/- 2%. Bus coupler: 2. I/O modules: >12, depending on the type. Maximum safe voltage Um: 60 V DC (SELV/PELV). Input voltage range: 18 ... 32 V DC (SELV/PELV). Power dissipation: approx. 15 % of power consumption. Power consumption: max. 30 W for Zone 2 applicationsmax. 45 W for applications in safe areaparallel connection with other LB9006C (autom. power sharing). Inrush current: 1.5 A (10 ms). Voltage: 5.4 V DC +/- 5% , 12 V DC + 4/- 2%. Power: P5V ≤ 5.4 W, P12V ≤ 25 W - P5V for Zone 2 applicationsP5V ≤ 5.4 W, P12V ≤ 39 W - P5V for applications in safe area. LED indication: Power LED (P) green: OFF in case of loss of 24 V or 12 V or 5 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Altitude: max. 2000 m. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , mounted on backplane. Mass: approx. 220 g. Dimensions: . Height100 mmWidth32.5 mmDepth102 mm: . Height: 100 mm. Width: 32.5 mm. Depth: 102 mm. Certificate: PF 08 CERT 1234 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Galvanic isolation: . Output/power supply, internal busEN 60950-1 (Safety requirement: < 60 V, external supply SELV/PELV): . Output/power supply, internal bus: EN 60950-1 (Safety requirement: < 60 V, external supply SELV/PELV). Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010. ATEX approval: PF 08 CERT 1234 X. UL approval: E106378. IECEx approval: . IECEx certificateIECEx BVS 09.0037XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx BVS 09.0037X. IECEx marking: Ex nA IIC T4 Gc. System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Slots
| Bus coupler | 2 |
| I/O modules | >12, depending on the type |
Supply
| Maximum safe voltage Um | 60 V DC (SELV/PELV) |
| Input voltage range | 18 ... 32 V DC (SELV/PELV) U |
| Power dissipation | approx. 15 % of power consumption |
| Power consumption | max. 30 W for Zone 2 applicationsmax. 45 W for applications in safe areaparallel connection with other LB9006C (autom. power sharing) |
| Inrush current | 1.5 A (10 ms) |
Output
| Voltage | 5.4 V DC +/- 5% , 12 V DC + 4/- 2% |
| Power | P5V ≤ 5.4 W, P12V ≤ 25 W - P5V for Zone 2 applicationsP5V ≤ 5.4 W, P12V ≤ 39 W - P5V for applications in safe area |
Indicators/settings
| LED indication | Power LED (P) green: OFF in case of loss of 24 V or 12 V or 5 V |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Altitude | max. 2000 m |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , mounted on backplane |
| Mass | approx. 220 g |
| Dimensions | |
| Height100 mmWidth32.5 mmDepth102 mm | Height |
| Height | 100 mm |
| Width | 32.5 mm |
| Depth | 102 mm |
Data for application in connection with hazardous areas
| Certificate | PF 08 CERT 1234 X |
| Marking II 3 G Ex nA IIC T4 Gc | Marking |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Galvanic isolation | |
| Output/power supply, internal busEN 60950-1 (Safety requirement: < 60 V, external supply SELV/PELV) | Output/power supply, internal bus |
| Output/power supply, internal bus | EN 60950-1 (Safety requirement: < 60 V, external supply SELV/PELV) |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 |
International approvals
| ATEX approval | PF 08 CERT 1234 X |
| UL approval | E106378 |
| IECEx approval | |
| IECEx certificateIECEx BVS 09.0037XIECEx markingEx nA IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx BVS 09.0037X |
| IECEx marking | Ex nA IIC T4 Gc |
General information
| System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G