Pepperl Fuchs LB8106*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB8106* be shipped?
LB8106* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB8106* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB8106* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB8106*, subject to availability and destination.
EasyCom Com Unit for PROFIBUS DP/DP-V1. Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: PROFIBUS DP/DP-V1. Connection: backplane bus. Rated voltage: 5 V DC , only in connection with the power supplies LB9***. Power consumption: 2 W. Fieldbus type: PROFIBUS DP/DP-V1. PROFIBUS DP: . Connection9-pin Sub-D socket via backplaneBaud rateup to 1.5 MBit/sProtocolPROFIBUS DP/DP V1 read/write services: . Connection: 9-pin Sub-D socket via backplane. Baud rate: up to 1.5 MBit/s. Protocol: PROFIBUS DP/DP V1 read/write services. Number of stations per bus line: max. 125 (PROFIBUS), max. 119 (service bus). Cyclic process data: 240 bytes input and (simultaneously) 240 bytes output. Number of stations per bus segment: max. 31 (RS-485 standard). Number of repeaters between Master and Slave: max. 3. Supported I/O modules: all LB remote I/O modules. Bus length: max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd). Addressing: via configuration software. PROFIBUS address: 0 ... 126 (factory standard setting: 126). GSE file: CGV61711.gsd/gse. HART communication: via PROFIBUS or service bus. Connection: backplane bus. Redundancy: via backplane. LED indicator: LED 1 (power supply): On = operating, fast flash = cold start LED 2 (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED 3 (status process bus): flashing = PROFIBUS receive channel active LED 4 (status service bus): flashing = service bus receive channel active LED 5 (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 6 (status process bus): flashing = PROFIBUS response channel active LED 7 (status servicebus): flashing = service bus response channel active. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1: . Directive 2014/30/EU: EN 61326-1. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , mounted on backplane. Connection: via backplane. Mass: approx. 120 g. Dimensions: 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch). Certificate: PF 08 CERT 1234 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010. ATEX approval: PF 08 CERT 1234 X. UL approval: E106378. Control drawing116-0321Approved forcUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G: . Control drawing: 116-0321. Approved for: cUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G. IECEx approval: BVS 09.0037X. Approved forEx nA IIC T4 Gc: . Approved for: Ex nA IIC T4 Gc. EAC approval: Russia: RU C-IT.MIII06.B.00129. Marine approval: . Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV: . Lloyd Register: 15/20021. DNV GL Marine: TAA0000034. American Bureau of Shipping: T1450280/UN. Bureau Veritas Marine: 22449/B0 BV
Specifications
Supply
| Connection | backplane bus |
| Rated voltage | 5 V DC , only in connection with the power supplies LB9*** Ur |
| Power consumption | 2 W |
Fieldbus connection
| Fieldbus type | PROFIBUS DP/DP-V1 |
| PROFIBUS DP | |
| Connection9-pin Sub-D socket via backplaneBaud rateup to 1.5 MBit/sProtocolPROFIBUS DP/DP V1 read/write services | Connection |
| Connection | 9-pin Sub-D socket via backplane |
| Baud rate | up to 1.5 MBit/s |
| Protocol | PROFIBUS DP/DP V1 read/write services |
| Number of stations per bus line | max. 125 (PROFIBUS), max. 119 (service bus) |
| Cyclic process data | 240 bytes input and (simultaneously) 240 bytes output |
| Number of stations per bus segment | max. 31 (RS-485 standard) |
| Number of repeaters between Master and Slave | max. 3 |
| Supported I/O modules | all LB remote I/O modules |
| Bus length | max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd) |
| Addressing | via configuration software |
| PROFIBUS address | 0 ... 126 (factory standard setting: 126) |
| GSE file | CGV61711.gsd/gse |
| HART communication | via PROFIBUS or service bus |
Internal bus
| Connection | backplane bus |
| Redundancy | via backplane |
Indicators/settings
| LED indicator | LED 1 (power supply): On = operating, fast flash = cold start LED 2 (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED 3 (status process bus): flashing = PROFIBUS receive channel active LED 4 (status service bus): flashing = service bus receive channel active LED 5 (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 6 (status process bus): flashing = PROFIBUS response channel active LED 7 (status servicebus): flashing = service bus response channel active |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , mounted on backplane |
| Connection | via backplane |
| Mass | approx. 120 g |
| Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
Data for application in connection with hazardous areas
| Certificate | PF 08 CERT 1234 X |
| Marking II 3 G Ex nA IIC T4 Gc | Marking |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 |
International approvals
| ATEX approval | PF 08 CERT 1234 X |
| UL approval | E106378 |
| Control drawing116-0321Approved forcUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G | Control drawing |
| Control drawing | 116-0321 |
| Approved for | cUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G |
| IECEx approval | BVS 09.0037X |
| Approved forEx nA IIC T4 Gc | Approved for |
| Approved for | Ex nA IIC T4 Gc |
| EAC approval | Russia: RU C-IT.MIII06.B.00129 |
| Marine approval | |
| Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV | Lloyd Register |
| Lloyd Register | 15/20021 |
| DNV GL Marine | TAA0000034 |
| American Bureau of Shipping | T1450280/UN |
| Bureau Veritas Marine | 22449/B0 BV |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G