Pepperl Fuchs HiC2853R2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiC2853R2 be shipped?
HiC2853R2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiC2853R2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiC2853R2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiC2853R2, subject to availability and destination.
Switch Amplifier. 1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Usable as signal splitter (1 input and 2 outputs), Application-specific outputs, Active voltage output, Passive transistor output (resistive), Line fault detection (LFD), Line fault transparency (LFT), Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3. Signal type: Digital Input. Safety Integrity Level (SIL): SIL 3. Systematic capability (SC): SC 3. Connection: SL1: 1a(-), 1b(-); 2a(+), 2b(+). Rated voltage: 19 ... 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 55 mA. Power dissipation: ≤ 800 mW. Power consumption: ≤ 1300 mW. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Open circuit voltage/short-circuit current: approx. 8.4 V DC / approx. 11.9 mA. Switching point/switching hysteresis: 2.1 ... 2.8 mA / approx. 0.3 mA. Line fault detection: breakage I ≤ 0.15 mA , short-circuit I ≥ 8.5 mA. Lead resistance: max. 50 Ω , consider capacitances and inductances. Switching point: 1-signal: I > 2.8 mA0-signal: I < 2.1 mA. Response delay: ≤ 1 ms. Connection side: control side. Connection: SL1: 8a(+), 7a(-); 10a(+), 9a(-). Rated voltage: output I: 19 ... 30 V DC. Output I: passive transistor output (resistive) 0-signal: 15 kΩ ± 5 %1-signal: 5 kΩ ± 5 % fault: > 100 kΩ. Output II: active voltage output, short-circuit proof 0-signal: 0 V1-signal: 20 ... 31 V DC at max. 15 mA fault: 0 V. Connection: SL1: 6b. Output type: open collector transistor (internal fault bus). Switching frequency: . Output I≤ 50 HzOutput II≤ 50 Hz: . Output I: ≤ 50 Hz. Output II: ≤ 50 Hz. Output/power supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Output/Output: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Display elements: LEDs. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: EN IEC 61326-3-2:2018 , NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Mass: approx. 105 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Height106 mmWidth12.5 mmDepth128 mm: . Height: 106 mm. Width: 12.5 mm. Depth: 128 mm. Mounting: on termination board. Coding: pin 1 and 2 trimmed For further information see system description.. EU-type examination certificate: BASEEFA 07 ATEX 0302X. Marking II (1)G [Ex ia] IIC , [exsign] II (1) D [Ex ia] IIIC , [exsign] I (M1) [Ex ia] IInputEx iaVoltageUo10.5 VCurrentIo17.1 mAPowerPo45 mW (linear characteristic): . Marking: II (1)G [Ex ia] IIC , [exsign] II (1) D [Ex ia] IIIC , [exsign] I (M1) [Ex ia] I. Input: Ex ia. Voltage: 10.5 V. Current: 17.1 mA. Power: 45 mW (linear characteristic). Supply: . Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.). Output: . Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.). Certificate: PF 09 CERT 1440 X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. UL approval: E106378. Control drawing116-0364: . Control drawing: 116-0364. IECEx approval: . IECEx certificateIECEx BAS 07.0097XIECEx marking[Ex ia Ga] IIC, [Ex ia] IIIC , [Ex ia] I: . IECEx certificate: IECEx BAS 07.0097X. IECEx marking: [Ex ia Ga] IIC, [Ex ia] IIIC , [Ex ia] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Digital Input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
| Rated voltage | 19 ... 30 V DC bus powered via Termination Board Ur |
| Ripple | ≤ 10 % |
| Rated current | ≤ 55 mA Ir |
| Power dissipation | ≤ 800 mW |
| Power consumption | ≤ 1300 mW |
Input
| Connection side | field side |
| Connection | SL2: 5a(+), 5b(-) |
| Open circuit voltage/short-circuit current | approx. 8.4 V DC / approx. 11.9 mA |
| Switching point/switching hysteresis | 2.1 ... 2.8 mA / approx. 0.3 mA |
| Line fault detection | breakage I ≤ 0.15 mA , short-circuit I ≥ 8.5 mA |
| Lead resistance | max. 50 Ω , consider capacitances and inductances |
| Switching point | 1-signal: I > 2.8 mA0-signal: I < 2.1 mA |
| Response delay | ≤ 1 ms |
Output
| Connection side | control side |
| Connection | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
| Rated voltage | output I: 19 ... 30 V DC Ur |
| Output I | passive transistor output (resistive) 0-signal: 15 kΩ ± 5 %1-signal: 5 kΩ ± 5 % fault: > 100 kΩ |
| Output II | active voltage output, short-circuit proof 0-signal: 0 V1-signal: 20 ... 31 V DC at max. 15 mA fault: 0 V |
Fault indication output
| Connection | SL1: 6b |
| Output type | open collector transistor (internal fault bus) |
Transfer characteristics
| Switching frequency | |
| Output I≤ 50 HzOutput II≤ 50 Hz | Output I |
| Output I | ≤ 50 Hz |
| Output II | ≤ 50 Hz |
Galvanic isolation
| Output/power supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Output/Output | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Indicators/settings
| Display elements | LEDs |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | EN IEC 61326-3-2:2018 , NE 21:2017For further information see system description. |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 105 g |
| Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Height106 mmWidth12.5 mmDepth128 mm | Height |
| Height | 106 mm |
| Width | 12.5 mm |
| Depth | 128 mm |
| Mounting | on termination board |
| Coding | pin 1 and 2 trimmed For further information see system description. |
Data for application in connection with hazardous areas
| EU-type examination certificate | BASEEFA 07 ATEX 0302X |
| Marking II (1)G [Ex ia] IIC , [exsign] II (1) D [Ex ia] IIIC , [exsign] I (M1) [Ex ia] IInputEx iaVoltageUo10.5 VCurrentIo17.1 mAPowerPo45 mW (linear characteristic) | Marking |
| Marking | II (1)G [Ex ia] IIC , [exsign] II (1) D [Ex ia] IIIC , [exsign] I (M1) [Ex ia] I |
| Input | Ex ia |
| Voltage | 10.5 V Uo |
| Current | 17.1 mA Io |
| Power | 45 mW (linear characteristic) Po |
| Supply | |
| Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) Um |
| Output | |
| Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) Um |
| Certificate | PF 09 CERT 1440 X |
| Marking II 3G Ex nA IIC T4 Gc | Marking |
| Marking | II 3G Ex nA IIC T4 Gc |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| UL approval | E106378 |
| Control drawing116-0364 | Control drawing |
| Control drawing | 116-0364 |
| IECEx approval | |
| IECEx certificateIECEx BAS 07.0097XIECEx marking[Ex ia Ga] IIC, [Ex ia] IIIC , [Ex ia] I | IECEx certificate |
| IECEx certificate | IECEx BAS 07.0097X |
| IECEx marking | [Ex ia Ga] IIC, [Ex ia] IIIC , [Ex ia] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G

