Pepperl Fuchs HiATB01-FAULT-01
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiATB01-FAULT-01 be shipped?
HiATB01-FAULT-01 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiATB01-FAULT-01 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiATB01-FAULT-01 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiATB01-FAULT-01, subject to availability and destination.
Fault Indication Board. 1-channel, 24 V DC supply, Monitors up to 16 HiC Termination Boards, Relay contact output, LEDs for supply and fault status. Connection: SL1: terminals 3, 5(+); 4, 6(-). Rated voltage: 19.6 ... 30 V DC. Ripple: ≤ 10 %. Power dissipation: ≤ 500 mW. Reverse polarity protection: yes. Supply: Redundancy available. The supply is decoupled and monitored.. Connection: fault bus (Fault) : SL1: terminals 1, 2 fault output : SL2: terminals 1, 2. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC , 1 A. Display elements: LED Power (power supply), green LEDLED Supply I (missing supply I), red LEDLED Supply II (missing supply II), red LEDLED Fault (fault signal), red LED - LED flashes: module fault/power supply fault at the termination board. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: . Supplypluggable screw terminals , blackFault outputpluggable screw terminals , black: . Supply: pluggable screw terminals , black. Fault output: pluggable screw terminals , black. Core cross section: screw terminals: 0.2 ... 2.5 mm2 (24 ... 12 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 165 g. Dimensions: 50 x 200 x 63 mm (1.97 x 7.9 x 2.48 inch) (W x H x D). Height200 mmWidth50 mmDepth63 mm: . Height: 200 mm. Width: 50 mm. Depth: 63 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | SL1: terminals 3, 5(+); 4, 6(-) |
| Rated voltage | 19.6 ... 30 V DC Ur |
| Ripple | ≤ 10 % |
| Power dissipation | ≤ 500 mW |
| Reverse polarity protection | yes |
Redundancy
| Supply | Redundancy available. The supply is decoupled and monitored. |
Fault indication output
| Connection | fault bus (Fault) : SL1: terminals 1, 2 fault output : SL2: terminals 1, 2 |
| Output type | volt-free contact |
| Switch behaviour | no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open |
| Contact loading | 30 V DC , 1 A |
Indicators/settings
| Display elements | LED Power (power supply), green LEDLED Supply I (missing supply I), red LEDLED Supply II (missing supply II), red LEDLED Fault (fault signal), red LED - LED flashes: module fault/power supply fault at the termination board |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017For further information see system description. |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | |
| Supplypluggable screw terminals , blackFault outputpluggable screw terminals , black | Supply |
| Supply | pluggable screw terminals , black |
| Fault output | pluggable screw terminals , black |
| Core cross section | screw terminals: 0.2 ... 2.5 mm2 (24 ... 12 AWG) |
| Material | housing: polycarbonate, 10 % glass fiber reinforced |
| Mass | approx. 165 g |
| Dimensions | 50 x 200 x 63 mm (1.97 x 7.9 x 2.48 inch) (W x H x D) |
| Height200 mmWidth50 mmDepth63 mm | Height |
| Height | 200 mm |
| Width | 50 mm |
| Depth | 63 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs HiACA-UNI-FLK34-FLK34-3M0
Available on requestPepperl Fuchs HiACA-UNI-FLK34-FLK34-6M0
Available on requestPepperl Fuchs HiALC-HiCTB-SET-108
Available on requestPepperl Fuchs HiALC-HiCTF-SET-114
Available on requestPepperl Fuchs HiATB01-HART-2X16
Available on requestPepperl Fuchs HiATB01-HART-4X8
Available on requestPepperl Fuchs HiATB01-HART-4X8-Y1
Available on requestPepperl Fuchs HiC2000 Blank