Pepperl Fuchs FJ7-N
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FJ7-N be shipped?
FJ7-N is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FJ7-N in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FJ7-N and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FJ7-N, subject to availability and destination.
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Gb: PTB 00 ATEX 2032 X, Equipment protection level Gc (ic): PF13CERT2895 X, Connection type: cable, Housing material: brass, zinc plated, Degree of protection: IP67. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 7 mm. Installation: flush. Assured operating distance: 0 ... 5.67 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 5 ... 25 V. Switching frequency: 0 ... 200 Hz. Hysteresis: typ. %. Current consumption: . Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage: . Measuring plate not detected: ≥ 3 mA at nominal voltage. Measuring plate detected: ≤ 1 mA at nominal voltage. Switching state indicator: LED, yellow. MTTFd: 4080 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GbIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GbPTB 00 ATEX 2032 XEquipment protection level Gc (ic)PF13CERT2895 X: . Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Gc (ic): PF13CERT2895 X. CCC approval: . Hazardous Location2020322315002304: . Hazardous Location: 2020322315002304. NEPSI approval: . NEPSI certificateGYJ16.1394X: . NEPSI certificate: GYJ16.1394X. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 ... 100 °C (-13 ... 212 °F). Cable, fixed installation-25 ... 80 °C (-13 ... 176 °F): . Cable, fixed installation: -25 ... 80 °C (-13 ... 176 °F). Connection type: cable. Housing material: brass, zinc plated. Sensing face: POM. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblueNumber of cores2Core cross section0.34 mm2LengthL2 m: . Wire end ferrules: yes. Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PUR. Color: blue. Number of cores: 2. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Height24 mmWidth50 mmLength25 mm: . Height: 24 mm. Width: 50 mm. Length: 25 mm. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 7 mm sn |
| Installation | flush |
| Assured operating distance | 0 ... 5.67 mm sa |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) Uo |
| Operating voltage | 5 ... 25 V UB |
| Switching frequency | 0 ... 200 Hz f |
| Hysteresis | typ. % H |
| Current consumption | |
| Measuring plate not detected≥ 3 mA at nominal voltageMeasuring plate detected≤ 1 mA at nominal voltage | Measuring plate not detected |
| Measuring plate not detected | ≥ 3 mA at nominal voltage |
| Measuring plate detected | ≤ 1 mA at nominal voltage |
| Switching state indicator | LED, yellow |
Safety-relevant product characteristics
| MTTFd | 4080 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
| NAMUREN 60947-5-6:2000StandardsEN IEC 60947-5-2 | NAMUR |
| NAMUR | EN 60947-5-6:2000 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GbIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X | Equipment protection level Gb |
| Equipment protection level Gb | IECEx PTB 11.0021X |
| Equipment protection level Mb | IECEx PTB 11.0021X |
| ATEX approval | |
| Equipment protection level GbPTB 00 ATEX 2032 XEquipment protection level Gc (ic)PF13CERT2895 X | Equipment protection level Gb |
| Equipment protection level Gb | PTB 00 ATEX 2032 X |
| Equipment protection level Gc (ic) | PF13CERT2895 X |
| CCC approval | |
| Hazardous Location2020322315002304 | Hazardous Location |
| Hazardous Location | 2020322315002304 |
| NEPSI approval | |
| NEPSI certificateGYJ16.1394X | NEPSI certificate |
| NEPSI certificate | GYJ16.1394X |
| CML approval | on request |
| ANZEx | 19.3001X |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Cable, fixed installation-25 ... 80 °C (-13 ... 176 °F) | Cable, fixed installation |
| Cable, fixed installation | -25 ... 80 °C (-13 ... 176 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | brass, zinc plated |
| Sensing face | POM |
| Degree of protection | IP67 |
| Cable | |
| Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPURColorblueNumber of cores2Core cross section0.34 mm2LengthL2 m | Wire end ferrules |
| Wire end ferrules | yes |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PUR |
| Color | blue |
| Number of cores | 2 |
| Core cross section | 0.34 mm2 |
| Length | 2 m L |
| Dimensions | |
| Height24 mmWidth50 mmLength25 mm | Height |
| Height | 24 mm |
| Width | 50 mm |
| Length | 25 mm |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G