Available on request

Pepperl Fuchs 6500-01-*-PNO-LNO

MPN: 6500-01-*-PNO-LNO · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryPurge and Pressurization System (Ex pxb)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can 6500-01-*-PNO-LNO be shipped?

6500-01-*-PNO-LNO is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6500-01-*-PNO-LNO in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6500-01-*-PNO-LNO and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6500-01-*-PNO-LNO, subject to availability and destination.

6500 Series Control Unit, Type Ex pxb and Ex pyb. 6500 series Ex pxb and Ex pyb purge and pressurization system. Operating mode: user programmable. Series: 6500. System: Ex pxb Purge , Ex pyb Purge. Number of volume exchanges: 5 to 19. Hazardous environment: gas, dust, gas and dust. Safety Integrity Level (SIL): SIL 2. Rated voltage: 100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC. Connection: EPCU: Terminal blocks and grounding screwUIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 metersInput type: intrinsically safe. Physical: Bluetooth® 4.1. Transmitter frequency: 2.4 ... 2.4835 GHz. Transmitter radiated power: -19 ... 7.5 dBm. Sensitivity: -92.5 dBm at 0.1 % BER. Detection range: 100 m in air. Antenna: PCB. Bluetooth: declaration ID: D037849. Input I: Voltage free contact or namur proximity sensor. Input typeIntrinsically Safe, Ex ib: . Input type: Intrinsically Safe, Ex ib. Input II: (1) 2-wire, PT100 RTD. Input typeIntrinsically Safe, Ex ib: . Input type: Intrinsically Safe, Ex ib. Output I: AUX. Output typeVoltage free contact outputs, SPDT configurationInrush current2 AContact loading2 A @ 240VAC, resistive, 2 A @ 24VDC: . Output type: Voltage free contact outputs, SPDT configuration. Inrush current: 2 A. Contact loading: 2 A @ 240VAC, resistive, 2 A @ 24VDC. Output II: Enclosure. Output typeVoltage free contact outputs, 2 N.O. configurationInrush current8 AContact loading8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °CFuseExternal fusing is required at no more than 11 amps/1500 A breaking current: . Output type: Voltage free contact outputs, 2 N.O. configuration. Inrush current: 8 A. Contact loading: 8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °C. Fuse: External fusing is required at no more than 11 amps/1500 A breaking current. Output III: Digital valve When used with the 6500-MAN-DV-01, intrinsically safe Internal resistance 280 Ω. Output IV: Proportional valveWhen used with the 6500-MAN-PV-01, intrinsically safeCurrent: 4 to 20 mAMax. load: 300 Ω. Communication: HART via RS485 (PACTware available). Display elements: 2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons. LED indication: Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault Key: green - a button on the capacitive touch display has been activated. Momentary indication. Protective gas supply: instrument grade air or inert gas. Pressure requirement: For 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120 psig) regulatedFor 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulatedNote: max. pressure will depend on the vent model used.. Safe pressure: Gas: 0.82 mbar (0.33 in wc) Dust: 0.82 mbar (0.33 in wc) Gas+Dust: 0.82 mbar (0.33 in wc). Valve flows: Standard vent series: EPV-6500-*-01, 03, 05Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).Minimum and maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent. Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent.. Ambient temperature: -20 ... 70 °C (-4 ... 158 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Relative humidity: 5 ... 85 %, non-condensing. Vibration resistance: 5 ... 100 Hz , 1 g, 12 m/s2, all axes. Impact resistance: 30 g, 11 ms, all axes. Connection type: See mounting in 6500 manual and cable gland requirements. Cable gland: Cable gland requirement: cable glands are not included. Customer can supply their own approved glands or use one of the 6500-CBLG-... cable gland kits.I.S.cable glands: requires (5) M12 approved cable glandsPower cable glands: requires (2) M16 and (2) M12 approved cable glands. Degree of protection: IP66. Material: UIC display: Makrolon FI cover and A380 Aluminum anodized casingHousing: 316L stainless steelHardware: 316L stainless steel. Mass: approx. 5 kg (11.0 lbs). Dimensions: 6500-01-EXT1: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7") 6500-01-PM01: 150 x 150 x 185 mm (5.9" x 5.9" x 7.3") 6500-01-PM02: EPCU: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7"), UIC: 150 x 150 x 45 mm (5.9" x 5.9" x 1.8"). Height367.5 mmWidth183 mmDepth152.5 mm: . Height: 367.5 mm. Width: 183 mm. Depth: 152.5 mm. Certificate: DEMKO 16 ATEX 1640X. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014. IECEx approval: IECEx UL 16.0003X. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Operating modeuser programmable
Series6500
SystemEx pxb Purge , Ex pyb Purge
Number of volume exchanges5 to 19
Hazardous environmentgas, dust, gas and dust

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Rated voltage100 ... 240 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC Ur

Electrical specifications

ConnectionEPCU: Terminal blocks and grounding screwUIC: 4-pin conncector and cable (provided), for the 6500-01-PM02, cable length is 5 metersInput type: intrinsically safe

Interface

PhysicalBluetooth® 4.1
Transmitter frequency2.4 ... 2.4835 GHz
Transmitter radiated power-19 ... 7.5 dBm
Sensitivity-92.5 dBm at 0.1 % BER
Detection range100 m in air
AntennaPCB

Communication

Bluetoothdeclaration ID: D037849

Input

Input IVoltage free contact or namur proximity sensor
Input typeIntrinsically Safe, Ex ib Input type
Input typeIntrinsically Safe, Ex ib
Input II(1) 2-wire, PT100 RTD
Input typeIntrinsically Safe, Ex ib Input type
Input typeIntrinsically Safe, Ex ib

Output

Output IAUX
Output typeVoltage free contact outputs, SPDT configurationInrush current2 AContact loading2 A @ 240VAC, resistive, 2 A @ 24VDC Output type
Output typeVoltage free contact outputs, SPDT configuration
Inrush current2 A
Contact loading2 A @ 240VAC, resistive, 2 A @ 24VDC
Output IIEnclosure
Output typeVoltage free contact outputs, 2 N.O. configurationInrush current8 AContact loading8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °CFuseExternal fusing is required at no more than 11 amps/1500 A breaking current Output type
Output typeVoltage free contact outputs, 2 N.O. configuration
Inrush current8 A
Contact loading8A @ 240 V AC, resistive up to 60 °C 8A @ 24 V DC up to 60 °C 5A @ 240 V AC, resistive, 60 to 70 °C 5A @ 24 V DC up to 60 to 70 °C
FuseExternal fusing is required at no more than 11 amps/1500 A breaking current
Output IIIDigital valve When used with the 6500-MAN-DV-01, intrinsically safe Internal resistance 280 Ω
Output IVProportional valveWhen used with the 6500-MAN-PV-01, intrinsically safeCurrent: 4 to 20 mAMax. load: 300 Ω
CommunicationHART via RS485 (PACTware available)

Indicators/settings

Display elements2x20 LCD for configuration, monitoring, and status of the 65000 system with back light and contrast selection. Capacitive touch buttons
LED indicationSafe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault Key: green - a button on the capacitive touch display has been activated. Momentary indication

Pneumatic parameters

Protective gas supplyinstrument grade air or inert gas
Pressure requirementFor 6500-MAN-DV: 1.4 to 8.3 bar (20 to 120 psig) regulatedFor 6500-MAN-PV: 3.5 to 6.9 bar (50 to 100 psig) regulatedNote: max. pressure will depend on the vent model used.
Safe pressureGas: 0.82 mbar (0.33 in wc) Dust: 0.82 mbar (0.33 in wc) Gas+Dust: 0.82 mbar (0.33 in wc)
Valve flowsStandard vent series: EPV-6500-*-01, 03, 05Readout on display is from 56 to 850 l/min (2 to 30 scfm) in increments of 28l/min (1 scfm).Minimum and maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent. Continuous (Dilution) vent series: EPV-6500-*-07, 08Readout on display is from 17 to 226 l/min (0.6 to 8 scfm) continuous reading.Maximum reading depending on type of vent and supply pressure.See datasheet for EPV-6500 series vent.

Ambient conditions

Ambient temperature-20 ... 70 °C (-4 ... 158 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity5 ... 85 %, non-condensing
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes

Mechanical specifications

Connection typeSee mounting in 6500 manual and cable gland requirements
Cable glandCable gland requirement: cable glands are not included. Customer can supply their own approved glands or use one of the 6500-CBLG-... cable gland kits.I.S.cable glands: requires (5) M12 approved cable glandsPower cable glands: requires (2) M16 and (2) M12 approved cable glands
Degree of protectionIP66
MaterialUIC display: Makrolon FI cover and A380 Aluminum anodized casingHousing: 316L stainless steelHardware: 316L stainless steel
Massapprox. 5 kg (11.0 lbs)
Dimensions6500-01-EXT1: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7") 6500-01-PM01: 150 x 150 x 185 mm (5.9" x 5.9" x 7.3") 6500-01-PM02: EPCU: 150 x 150 x 145 mm (5.9" x 5.9" x 5.7"), UIC: 150 x 150 x 45 mm (5.9" x 5.9" x 1.8")
Height367.5 mmWidth183 mmDepth152.5 mm Height
Height367.5 mm
Width183 mm
Depth152.5 mm

Data for application in connection with hazardous areas

CertificateDEMKO 16 ATEX 1640X
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-5:2015 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-31:2014

International approvals

IECEx approvalIECEx UL 16.0003X

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote