Quick facts
| Availability | Confirmed on request |
| Category | ACOPOSinverter P77 - 1-phase 170 to 264 V |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.8 kg |
Shipping & availability
When can 8I77S200025.0P-000 be shipped?
8I77S200025.0P-000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8I77S200025.0P-000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8I77S200025.0P-000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I77S200025.0P-000, subject to availability and destination.
ACOPOSinverter P77, 1x 170-264 V; 0.25 kW (heavy duty), 1.7 A (@8 kHz), integrated brake chopper, HTL encoder input onboard, 2-channel STO (SIL 3, PL e), POWERLINK hub with 2x RJ45, physical node number switches, shield plate included in delivery
Specifications
Specifications
| CE | Yes |
| UKCA | Yes |
| UL | cULus E225616 Power conversion equipment |
| Specified on nameplate, 1-phase | 0.25 kW (0.33 PS) |
| Mains input voltage, 1-phase | 1x 170-264 V |
| Frequency | 45 to 65 Hz ±5% |
| Apparent power (at 120 VAC) | 0.6 kVA |
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point), 1-phase | 65 kA |
| Power dissipation | 15 W |
| At 200 VAC, 1-phase | 6.8 A |
| Integrated EMC filter | Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | C1 level of 4 to 8 kHz with 50 m cable |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | C2 level of 4 to 8 kHz with 50 m cable |
| Nominal output current | 1.7 A |
| At nominal clock frequency (4 kHz) | No derating (up to 50°C) |
| Other clock frequencies | The derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com. |
| Starting at 1000 m above sea level | 1%, per 100 m |
| Max. transient current for 15 s, 1-phase | 318 A |
| Output frequency range | 0.1 to 599 Hz |
| Nominal clock frequency | 4 kHz |
| Min. | 2 kHz |
| Max. | 16 kHz |
| Shielded cable | 50 m |
| Non-shielded cable | 80 m |
| Induction motor | Sensorless vector control: 1. Voltage controlled with constant torque → standard mode Slip control: 1. With V/f characteristic curve for constant torque → Standard mode 2. With V/f characteristic curve for constant torque (up to 6 f-ranges) → Mode for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps |
| Synchronous motor | Sensorless vector control: 1. Voltage controlled with constant torque → standard mode |
| Main protective functions of inverter | Thermal protection against power stage overheating Protection against: short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply |
| Integrated dynamic brake transistors | Yes |
| Min. resistance value (external) | 180 Ω |
| Max. output current | 2.2 A |
| Input voltage | 24 VDC (-15%/+20%) |
| Current | 2.2 kΩ |
| Output voltage 24 VDC | 24 VDC |
| Max. output current at 24 VDC | 2.6 A |
| Output voltage 10 VDC | 10 VDC (-0%/+10%) |
| Type | Type 3 |
| Quantity | 1 |
| Nominal voltage | 24 VDC / 240 |
| Input circuit | Source or sink |
| Sampling time | 1 ms |
| Current consumption | SIA: 10 mA SIB: 7 mA |
| Input - ACOPOSinverter | Yes |
| Input - Input | No |
| Basic accuracy | At 25°C: ±0.3 mA At -10 to 60°C: ±0.3 mA |
| Voltage | 2.2 kΩ |
| Max. voltage | 30 VDC |
| Output circuit | Source or sink |
| Max. current | 100 mA |
| Variant | 1 changeover contact |
| Switching current range | Min. switching current: 10 mA at 24 VDC Max. Switching current: AC 240 V - 3 A DC 24 V - 2 A DC 240 V - 0.16 A |
| Output | 0 to 10 V or 0 to 20 mA |
| Output - ACOPOSinverter | Yes |
| Output - Output | No |
| Resolution | 12-bit |
| Power dissipation relative to continuous apparent power | IE2 (0, 25): 2.2% IE2 (0, 50): 2.2% IE2 (0, 100): 2.4% IE2 (50, 25): 2.2% IE2 (50, 50): 2.3% IE2 (50, 100): 2.6% IE2 (90, 50): 2.4% iE2 (90, 100): 2.9% |
| Nominal losses in standby mode | 0.9% |
| Degree of protection per EN 61800-5-1 | IP20 |
| Max. relative humidity per IEC 60068-2-3 | <95%, non-condensing No dripping water |
| Maximum installation elevation | ≤1000 m without derating 1000 to 4000 m with Derating |
| Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S2 |
| Operation | -10 to 45°C without derating 45 to 60°C with derating |
| Storage | -25 to 60°C |
| Max. vibration resistance | Operation at switching frequency 2 or 4 kHz: Above +45°C, reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997 Operation at switching frequency 8 or 16 kHz: Above +40°C, reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997 |
| Width | 60 mm |
| Height | 214 mm |
| Depth | 130 mm |
| Weight | 0.8 kg |
More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 Used