B&R 8I64T401500.00X-1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 9 kg |
Shipping & availability
When can 8I64T401500.00X-1 be shipped?
8I64T401500.00X-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8I64T401500.00X-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8I64T401500.00X-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I64T401500.00X-1, subject to availability and destination.
ACOPOSinverter X64, 3x 380-500 V, 15 kW, integrated EMC filter and brake chopper, shield plate included in delivery, X2X Link interface
Specifications
Specifications
| Specified on nameplate | 15 kW 20 HP |
| Mains input voltage | 3x 380 VAC -15% to 500 VAC +10% |
| Frequency | 50 to 60 Hz ±5% |
| Apparent power (at 500 VAC) | 32 kVA |
| Max. assumed short-circuit current (Isc) (short-circuit current at connection point) | 22 kA |
| At 380 VAC | 48.2 A |
| At 500 VAC | 33 A |
| Power dissipation at max. output current | 492 W |
| Integrated EMC filter | Yes |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | ≤20 m |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | ≤50 m |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | ≤50 m |
| With add-on filter | 8I0FT049.200-1 |
| Clock frequency 4 kHz | No derating (up to 50°C) |
| Other clock frequencies | The derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com. |
| Starting at 1000 m above sea level | 1%, per 100 m |
| Max. transient current for 60 s | 49.5 A |
| Output frequency range | 0.5 to 500 Hz |
| Nominal clock frequency | 4 kHz |
| Min. | 10 mA for 5 VDC |
| Max. | 16 kHz |
| Short-term overload torque (typical value) | 170 to 200% of the nominal motor torque |
| With braking resistor | 100% of the nominal motor torque continuously, up to 150% for 60 s |
| Without braking resistor (typical value) | 30% of the nominal motor torque |
| Shielded cable | 50 m |
| Non-shielded cable | 100 m |
| Motor control profiles | Standard profile (voltage/frequency ratio - V/f characteristic curve) Power profile (flux vector control without encoder) Pump/Fan profile (quadratic characteristic curve Kn²) Energy-saving profile (especially for ventilation) |
| Main protective functions of inverter | Thermal protection against overheating Protection against short circuits between motor phases Protection against mains phase failure, for 3-phase power supply Protection against motor phase failures Overcurrent protection between motor output phases and ground Overvoltage and undervoltage protection for mains supply |
| Motor protection | Thermal protection integrated in the inverter through continually calculating the l²t value |
| Integrated dynamic brake transistors | Yes |
| Operating ratio for dynamic brake transistors | The dynamic brake transistor is designed to tolerate the following values: -Nominal motor power continuously -150% of the nominal motor power for 60 s |
| Min. resistance value (external) | 20 Ω |
| Output voltage | 24 VDC (min. 19 V, max. 30 V) |
| Max. output current | 100 mA |
| Type | X2X and CANopen |
| Min. cycle time | 400 µs |
| Quantity | 1 |
| Nominal voltage | 30 VDC / 250 VAC |
| Input circuit | Source or sink |
| Input - ACOPOSinverter | Yes |
| Input - Input | No |
| Sampling time | <4 ms |
| Input impedance | 12.1 kΩ |
| Counter frequency | 10 kHz |
| Counter size | 32-bit |
| Output circuit | Source |
| Nominal output current | 0.5 A |
| Variant | 1 NO contact |
| With resistive load (cos φ = 1 and L/R = 0 ms) | 2 A for 250 VAC or 30 VDC |
| With inductive load (cos φ = 0.4 and L/R = 7 ms) | 1.5 A for 250 VAC or 30 VDC |
| Response time (max.) | <8 ms |
| Output - ACOPOSinverter | Yes |
| Output - Output | No |
| Installation elevation above sea level | 0 to 1000 m |
| Degree of protection per EN 60529 | IP31 and IP41 on the upper part and IP21 on the terminals |
| Ambient temperature | -10 to 50°C |
| Max. ambient temperature | Up to +60°C |
| Relative humidity per IEC 60068-2-3 | 5 to 95%, non-condensing No dripping water |
| Maximum installation elevation | Up to 2000 m |
| Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S2 |
| Operating position | Vertical mounting orientation ±10% |
| Storage | -25 to 70°C |
| Width | 245 mm |
| Height | 329.5 mm |
| Depth | 192 mm |
| Weight | 9 kg |
More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 Used
UsedB&R 5PC720.1505-K07 - 5P62:0A-03 Used