Available on request
B&R 8I44T200150.000-1
MPN: 8I44T200150.000-1 · Brand: B&R
Price on request
Request a Quote
12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via


Quick facts
| Availability | Confirmed on request |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.2 kg |
Shipping & availability
When can 8I44T200150.000-1 be shipped?
8I44T200150.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8I44T200150.000-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8I44T200150.000-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I44T200150.000-1, subject to availability and destination.
ACOPOSinverter S44, 3x 200-240 V, 1.5 kW, RS485 interface
Specifications
Specifications
| KC | Yes |
| Specified on nameplate | 1.5 kW 2 PS |
| Mains input voltage | 3x 200 VAC -15% to 240 VAC +10% |
| Frequency | 50 to 60 Hz ±5% |
| Apparent power (at 240 VAC) | 3.9 kVA |
| Max. assumed short-circuit current (Isc)(short-circuit current at connection point) | 5000 A |
| At 200 VAC | 11.1 A |
| At 240 VAC | 10 A |
| Power dissipation at max. output current | 73 W |
| Integrated EMC filter | No |
| With add-on filter | 8I0FT015.100-1 |
| Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network) | ≤5 m |
| Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network) | ≤20 m |
| Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system) | ≤20 m |
| Clock frequency 4 kHz | No derating (up to 50°C) |
| Other clock frequencies | The derating curves are included in the user's manual, which can be downloaded from the homepage (www.br-automation.com). |
| Starting at 1000 m above sea level | 1%, per 100 m |
| Max. transient current for 60 s | 15 A |
| Output frequency range | 0.5 to 400 Hz |
| Nominal clock frequency | 4 kHz |
| Min. | 5 mA for 24 VDC |
| Max. | 16 kHz |
| Braking torque | Up to 70% of the rated motor torque without resistance |
| Shielded cable | 50 m |
| Non-shielded cable | 100 m |
| Motor control profiles | Standard profile (voltage/frequency ratio - U/f characteristic curve)Performance profile (flux vector control without encoder)Pump/fan profile (quadratic characteristic curve Kn²), |
| Main protective functions of inverter | Thermal protection against overheating Protection against short circuits between motor phases Overcurrent protection between motor phases and ground Protection against overvoltage and undervoltage on the mains supply Protection against mains phase failure on a 3-phase supply |
| Motor protection | Thermal protection through continually calculating the l²t value integrated in the inverter |
| Short-term overload torque | 150 to 170% of the rated torque depending on the inverter power and motor type |
| Output voltage 5 VDC | 5 VDC ±5% |
| Max. output current at 5 VDC | 10 mA |
| Output voltage 24 VDC | 24 VDC -15% / +20% |
| Max. output current at 24 VDC | 100 mA |
| Type | Modbus RTU |
| Quantity | 1 |
| Nominal voltage | 30 VDC / 250 VAC |
| Input circuit | Sink or source |
| Input - ACOPOSinverter | Yes |
| Input - Input | No |
| Sampling time | <10 ms |
| Input impedance | 3.5 kΩ |
| Input | 0 to 5 V or 0 to 10 V or 0 to 20 mA |
| Resolution | 8-bit |
| Voltage | 470 Ω |
| Current | 800 Ω |
| Output circuit | Sink or source |
| Output - ACOPOSinverter | Yes |
| Output - Output | No |
| Nominal output current | 10 mA (100 mA with external supply) |
| Update time | <10 ms |
| Variant | 1 N.O. contact and 1 N.C. contact with a common point |
| With resistive load (cos φ = 1 and L/R = 0 ms) | 4 A at 30 VDC / 3 A at 250 VAC |
| With inductive load (cos φ = 0.4 and L/R = 7 ms) | 2 A at 30 VDC or 250 VAC |
| Response time (max.) | 30 ms |
| Output | 0 to 10 V or 0 to 20 mA |
| Installation elevation above sea level | 0 to 1000 m |
| Degree of protection per EN 60529 | IP20 |
| Ambient temperature | -10 to 50°C |
| Max. ambient temperature | Up to +60°C |
| Relative humidity per IEC 60068-2-3 | 5 to 95%, non-condensing No dripping water |
| Maximum installation elevation | Up to 2000 m |
| Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S2 |
| Operating position | Vertical installation +/10% |
| Storage | -25 to 70°C |
| Width | 105 mm |
| Height | 142 mm |
| Depth | 156.2 mm |
| Weight | 1.2 kg |
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide


More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 UsedMPN: 5C5001.01 IPC 5000 5D5500.06 · B&R
€1,588.94
View details
UsedB&R 5PC720.1505-K07 - 5P62:0A-03 UsedMPN: 5PC720.1505-K07 - 5P62:0A-03 · B&R
€2,012.94
View details