Available on request

B&R 8I44S100037.000-1

MPN: 8I44S100037.000-1 · Brand: B&R
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)
Weight0.8 kg

Shipping & availability

When can 8I44S100037.000-1 be shipped?

8I44S100037.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8I44S100037.000-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8I44S100037.000-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I44S100037.000-1, subject to availability and destination.

ACOPOSinverter S44, 1x 100-120 V, 0.37 kW, RS485 interface

Specifications

Specifications

CEYes
CRA (Cyber Resilience Act)Evaluation ongoing
ULcULus E225616 Power conversion equipment
KCYes
Specified on nameplate0.37 kW 0.5 HP
Mains input voltage1x 100 VAC -15% to 120 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 120 VAC)1.9 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)1000 A
At 100 VAC11.4 A
At 120 VAC2.4 A
Power dissipation at max. output current29 W
Integrated EMC filterNo
With add-on filter8I0FS011.100-1
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)≤5 m
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)≤20 m
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)≤20 m
Clock frequency 4 kHzNo derating (up to 40°C)
Other clock frequenciesThe derating curves are included in the user's manual, which can be downloaded from www.br-automation.com.
Starting at 1000 m above sea level1%, per 100 m
Max. transient current for 60 s3.6 A
Output frequency range0.5 to 400 Hz
Nominal clock frequency4 kHz
Min.5 mA for 24 VDC
Max.16 kHz
Braking torqueUp to 70% of the nominal motor torque without resistance
Shielded cable50 m
Non-shielded cable100 m
Motor control profilesStandard profile (voltage/frequency ratio - V/f characteristic curve) Power profile (flux vector control without encoder) Pump/Fan profile (quadratic characteristic curve Kn²)
Main protective functions of inverterThermal protection against overheating Protection against short circuits between motor phases Overcurrent protection between motor phases and ground Protection against overvoltage and undervoltage in the mains supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value
Short-term overload torque150 to 170% of the nominal motor torque depending on inverter power and motor type
Output voltage 5 VDC5 VDC ±5%
Max. output current at 5 VDC10 mA
Output voltage 24 VDC24 VDC -15% / +20%
Max. output current at 24 VDC100 mA
TypeModbus RTU
Quantity1
Nominal voltage30 VDC / 250 VAC
Input circuitSource or sink
Input - ACOPOSinverterYes
Input - InputNo
Sampling time<10 ms
Input impedance3.5 kΩ
Input0 to 5 V, 0 to 10 V or 0 to 20 mA
Resolution8-bit
Voltage470 Ω
Current800 Ω
Output circuitSource or sink
Output - ACOPOSinverterYes
Output - OutputNo
Nominal output current10 mA (100 mA with external power supply)
Update time<10 ms
Variant1 NO contact and 1 NC contact with a common point
With resistive load (cos φ = 1 and L/R = 0 ms)4 A at 30 VDC / 3 A at 250 VAC
With inductive load (cos φ = 0.4 and L/R = 7 ms)2 A at 30 VDC or 250 VAC
Response time (max.)30 ms
Output0 to 10 V or 0 to 20 mA
Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529IP20
Ambient temperature-10 to 40°C
Max. ambient temperatureUp to +60°C
Relative humidity per IEC 60068-2-35 to 95%, non-condensing No dripping water
Maximum installation elevationUp to 2000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Operating positionVertical mounting orientation ±10%
Storage-25 to 70°C
Width72 mm
Height130 mm
Depth121.2 mm
Weight0.8 kg
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More B&R parts

B&R X20SA4430 NewNewB&R X20SA4430 New
MPN: X20SA4430 · B&R
€952.94
View details
B&R 5C5001.01 IPC 5000 5D5500.06 UsedUsedB&R 5C5001.01 IPC 5000 5D5500.06 Used
MPN: 5C5001.01 IPC 5000 5D5500.06 · B&R
€1,588.94
View details
B&R 8BVI0028HWD0.000-1 Used Rev.O0UsedB&R 8BVI0028HWD0.000-1 Used Rev.O0
MPN: 8BVI0028HWD0.000-1 · B&R
€422.94
View details
B&R 5PC720.1505-K07 - 5P62:0A-03 UsedUsedB&R 5PC720.1505-K07 - 5P62:0A-03 Used
MPN: 5PC720.1505-K07 - 5P62:0A-03 · B&R
€2,012.94
View details