B&R 8BVI0110HWDS.000-1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Wall mounting |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 8BVI0110HWDS.000-1 be shipped?
8BVI0110HWDS.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8BVI0110HWDS.000-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8BVI0110HWDS.000-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8BVI0110HWDS.000-1, subject to availability and destination.
Clearly structured, straightforward implementation via network-based safety technologyModular expandability through virtual wiringImmediate triggering of safety function due to short cycle timesEasy implementation with transparent control and status information, even in the standard applicationCompact designComplete safety functionality, even in 2-axis modules ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 15.1 A, AS, wall mounting, 2 axes
Specifications
Specifications
| B&R ID code | 0xAA19 |
| Dynamic node allocation (DNA) | Yes |
| Cooling and mounting type | Wall mounting |
| Slots for plug-in modules | 2 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | Evaluation ongoing |
| Functional safety | Yes (openSAFETY) |
| UL | cULus E225616 Power conversion equipment |
| KC | Yes |
| Nominal | 5 to 40°C |
| Continuous power consumption | 22.3 kW |
| Switching frequency 5 kHz | 25 m |
| Switching frequency 10 kHz | 25 m |
| Switching frequency 20 kHz | 10 m |
| DC bus capacitance | 660 µF |
| Variant | ACOPOSmulti backplane |
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 23.5 µF |
| Max. power consumption | 32 W + PSMC1 + PSMC2 + P24 V Out + PHoldingBrake(s) |
| Quantity | 2 |
| DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC/315) |
| DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
| Continuous power per motor connection | 11 kW |
| Continuous current per motor connection | 15.1 Aeff |
| Starting at 500 m above sea level | 1.51 Aeff per 1000 m |
| Peak current per motor connection | 37.7 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| U, V, W, PE | Connector |
| Shield connection | Yes |
| With wire end sleeve | 0.25 to 4 mm² |
| UL/C-UL-US | 30 to 10 |
| CSA | 28 to 10 |
| Terminal cable cross section dimension of shield connection | 12 to 22 mm |
| Output voltage | Typ. 12.5 V |
| Continuous current per connection | 2.1 A |
| Max. internal resistance | 0.3 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 3 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open-circuit monitoring | Yes |
| Undervoltage monitoring | Yes |
| Response threshold for open-circuit monitoring | Approx. 0.5 A |
| Response threshold for undervoltage monitoring | 24 VDC -2% / -4% |
| Type | EnDat 2.2 |
| Connections | 9-pin female DSUB connector |
| Status indicators | UP/DN LEDs |
| Encoder - ACOPOSmulti | No |
| Encoder monitoring | Yes |
| Max. encoder cable length | 100 m Depends on the cross section of the power supply wires in the encoder cable |
| Load capacity | 350 mA |
| Short-circuit proof | Yes |
| Overload-proof | Yes |
| Signal transmission | RS485 |
| Data transfer rate | 6.25 Mbit/s |
| Max. power consumption per encoder interface | PSMC[W] = 19 V * IEncoder[A] |
| Circuit | Sink |
| Input - Inverter module | Yes |
| Input - Input | Yes |
| Maximum | 55°C |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | Approx. 10 mA |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Modulation compared to ground potential | Max. ±38 V |
| Resistance range | 500 Ω to 5 kΩ |
| Discharge capacitance | 0.44 µF |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 1.6% IE2 (50,25) 1.6% IE2 (10,50) 1.9% IE2 (50,50) 1.9% IE2 (90,50) 1.9% IE2 (10,100) 2.5% IE2 (50,100) 2.5% IE2 (90,100) 2.5% |
| Nominal losses in standby mode | 11.5 W |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 106.5 mm |
| Height | 317 mm |
| Wall mounting | 263 mm |
| Weight | Approx. 5.3 kg |
| Module width | 2 |
More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 Used
UsedB&R 5PC720.1505-K07 - 5P62:0A-03 Used