Filter module for field-side power supply (surge); 24 VDC; Higher isolation; Extreme
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 750-624/040-000 be shipped?
750-624/040-000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 750-624/040-000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 750-624/040-000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 750-624/040-000, subject to availability and destination.
<p>The WAGO‐I/O-SYSTEM 750 XTR can also be used in shipbuilding applications and onshore/offshore installations (e.g., platforms, loading facilities). This is verified by certification under the standards of leading </p>agencies such as Germanischer Lloyd and Lloyd's Register. This filter module ensures proper (certified) system operation. This also applies to XTR I/O Modules used in substations and/or telecontrol systems as well as railway technology.<br/><p>The following I/O modules are required for power supply: </p><p>750-626/040-000 Power Supply Filter (system and field supply), 750-624/040-000 or 750-624/040-001 Field-Side Power Supply Filter (only field supply).</p><p>750-624/040-001: For infeed without separate supply module</p><p>750-624/040-000: When used behind a supply module with fuse (750-601/040-000 or 750-610/040-000)</p><p><b>The device is ideal for operation in extreme environments thanks to:</b></p><ul><li>An extended temperature range</li><li>Greater immunity to impulse voltages and electromagnetic interference</li><li>Higher vibration and shock resistance</li></ul>
Specifications
Technical data
| Signal type | Voltage |
| Signal type (voltage) | 24 VDC |
| Supply voltage (system) | 5 VDC; via data contacts |
| Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission via spring contact); Derating must be observed! |
| Derating | Derating (supply voltage):Ambient temperatures under laboratory conditions: (-25 … +30 %);for -40 … +55 °C: 24 V (-25 … +20 %);for +55 … +70 °C: 24 V (-25 … +10 %);Lower limit in all temperature ranges: -27.5 % (including 15 % residual ripple) |
| Current carrying capacity (power jumper contacts) | 10 A |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Rated impulse withstand voltage | 1 kV |
| Use | in marine and onshore/offshore applications, as well as in telecontrol and rail technology |
| Indicators | LED (C) green: operating voltage status: power jumper contacts |
Connection data
| Connectable conductor materials | Copper |
| Connection type | Field supply |
| Solid conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Connection technology: field supply | 4 x CAGE CLAMP® |
Physical data
| Width | 12 mm / 0.472 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 60.6 mm / 2.386 inches |
Mechanical data
| Mounting type | DIN-35 rail |
Material data
| Color | dark gray |
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 0.945 MJ |
| Weight | 46.6 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | -40 … +70 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Ambient temperature (installation) | -20 … +70 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) |
| Mounting position | Horizontal left, horizontal up, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Relative humidity (with condensation) | Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation) |
| Vibration resistance | According to type test for marine classification (ABS, BV, DNV, IACS, LR): acceleration: 5g, IEC 60068-2-6, EN 60870-2-2, IEC 60721-3-1, -3, EN 50155, EN 61373 |
| Shock resistance | per IEC 60068-2-27 (10g/16 ms/half-sine/1,000 shocks; 25g/6 ms/half-sine/1,000 shocks), EN 50155, EN 61373 |
| EMC immunity to interference | per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994 |
| EMC emission of interference | per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5 |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4055143673563 |
| Customs tariff number | 85389091890 |
Product Classification
| UNSPSC | 39121610 |
| eCl@ss 10.0 | 27-24-26-10 |
| eCl@ss 9.0 | 27-24-26-10 |
| ETIM 9.0 | EC001600 |
| ETIM 10.0 | EC001600 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1 |
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 62e47fb4-9223-4b2c-8bab-e3744eeee737 |
| SCIP notification number (Belgium) | 97327366-1cf5-4c4e-8302-945ff8eef5fa |
| SCIP notification number (Bulgaria) | d63458f8-ce81-42ec-a3bd-e26eb2828d33 |
| SCIP notification number (Czech Republic) | 1de2db22-f463-4930-9329-d88533ea3f9b |
| SCIP notification number (Denmark) | 49bea55f-a7d3-4bb3-90c7-54f7a18cd299 |
| SCIP notification number (Finland) | 8430f996-6f12-45db-999b-1d22eace0999 |
| SCIP notification number (France) | 7b1e8d1f-1058-4e80-9f13-58c7f8b7a80e |
| SCIP notification number (Germany) | f920254b-c5c7-485f-9bcb-c581a4256c25 |
| SCIP notification number (Hungary) | 67be5329-b92f-4951-9eb5-abf4dfdec9dd |
| SCIP notification number (Italy) | a3c55f80-4ce5-49a0-91f4-d8ebe060bf4f |
| SCIP notification number (Netherlands) | 5c315479-5a1b-47eb-9ac8-7f37c79f1c4f |
| SCIP notification number (Poland) | 04497b2e-c4bc-4842-8296-2edd39e0c58f |
| SCIP notification number (Romania) | 7ba00f46-776a-439f-b3f8-1e848a2494f5 |
| SCIP notification number (Sweden) | 16889b1f-20c8-4e4e-a80c-2a2084607b52 |