8-channel digital input; PTC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 750-1425 be shipped?
750-1425 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 750-1425 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 750-1425 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 750-1425, subject to availability and destination.
<p>Just 12 mm wide, the PTC Module features eight channels to connect PTC thermistors according to DIN 44081 and DIN 44082 for thermal monitoring (overload protection) of motors, machinery, bearings, etc. </p><p>Up to six PTC thermistors can be connected in series per channel. If the nominal response temperature (ϑnat) is exceeded, a bit is set in the module's input process image. In addition, wire breaks and short circuits are monitored for each channel. If an error occurs, a bit is also set in the input process image. The module features one green and one red status LED per channel to indicate excessive temperatures or wiring errors. </p><p>Field and system levels are electrically isolated.</p><p>An operating tool with a 2.5 mm blade (210-719) is required to open the Push-in CAGE CLAMP<sup>®</sup> connections.</p>
Specifications
Technical data
| Number of digital inputs | 8 |
| Total number of channels (module) | 8 |
| Signal type | PTC, thermistor per DIN 44081/44082 |
| Sensor connection | 8 x (2-wire) |
| Specific sensor properties | Sensor voltage: ≤ 2.5 V / ≤ 7.5 V (based on resistance value); Number of PTCs per channel: max. 6 PTCs in series; Operating value (status bit “1” to “0”): R ≥ 3 kΩ; Return value (status bit “0” to “1”): ≤ 1.5 kΩ; Hysteresis: R = 1.5 kΩ; Wire break value: R ≥ 8 kΩ; Short circuit value: R ≤ 20 Ω |
| Input filter | 100 ms |
| Output current per channel | 0.001 A |
| Power consumption P<sub>max.</sub> | 260 mW |
| Input data width (internal) max. | 16 Bit |
| Data width | 16-bit input: 8-bit data, 8-bit error (short circuit/wire break) |
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 52 mA |
| Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact) |
| Isolation | 500 V system/field |
| Indicators | LED (1-8) green: Status 1T … 8T; LED (9-16) red: Error 1T … 8T |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Current carrying capacity (power jumper contacts) | 10 A |
Connection data
| Connection technology: I/O | 16 x Push-in CAGE CLAMP® (inputs) |
| Connectable conductor materials | Copper |
| Connection type | Input |
| Solid conductor | 0.08 … 1.5 mm² / 28 … 16 AWG |
| Fine-stranded conductor | 0.25 … 1.5 mm² / 22 … 16 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Physical data
| Width | 12 mm / 0.472 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 69 mm / 2.717 inches |
| Depth from upper-edge of DIN-rail | 61.8 mm / 2.433 inches |
Mechanical data
| Mounting type | DIN-35 rail |
| Pluggable connector | fixed |
Material data
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 0.624 MJ |
| Weight | 46.5 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | 0 … +55 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | 0 … 2000 m / 0 … 6562 ft |
| Mounting position | Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Vibration resistance | 4g per IEC 60068-2-6 |
| Shock resistance | 15g per IEC 60068-2-27 |
| EMC immunity to interference | per EN 61000-6-2, marine applications |
| EMC emission of interference | per EN 61000-6-4, marine applications |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| Product Group | 15 (I/O System) |
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4050821880745 |
| Customs tariff number | 85389099990 |
Product Classification
| UNSPSC | 32151705 |
| eCl@ss 10.0 | 27-24-26-04 |
| eCl@ss 9.0 | 27-24-26-04 |
| ETIM 9.0 | EC001599 |
| ETIM 10.0 | EC001599 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 11120-22-2, 1303-86-2, 1317-36-8, 7439-92-1 |
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Lead silicate |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 7(a), 7(c)-I, 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 4004bc2d-84e2-4e5d-88b5-1ea554b968cb |
| SCIP notification number (Belgium) | e5071e4b-8232-4c3a-9642-80db5f9a99f8 |
| SCIP notification number (Bulgaria) | 63a62127-ee7a-4082-9a0d-f9303bfe0dd5 |
| SCIP notification number (Czech Republic) | c177a7ef-710f-42f9-8dcb-8cdabc64b57d |
| SCIP notification number (Denmark) | dbcd88f3-cf4b-45b1-9b1f-5b54c20aca67 |
| SCIP notification number (Finland) | 29b8798c-8c72-44cb-9f5e-1a2fdef48e4b |
| SCIP notification number (France) | 2e6293c1-1032-4396-81ee-fe633522d2df |
| SCIP notification number (Germany) | 954fd304-ced3-4bd1-8fc2-43e803d1833a |
| SCIP notification number (Hungary) | 234f7ff7-8553-4767-b401-628c4657aecb |
| SCIP notification number (Italy) | 445e5bfd-493a-45be-b4c3-eb9662e6f16d |
| SCIP notification number (Netherlands) | 50d7bb51-2d65-4d36-b614-070a749f1d1a |
| SCIP notification number (Poland) | 21f3f129-20d8-42ad-8fa7-01795aff99e6 |
| SCIP notification number (Romania) | 642e6602-5dfb-4837-ab80-25e9acb4fadf |
| SCIP notification number (Sweden) | 09e5b0d7-19b3-43a2-8346-7b0f57733e7d |