Through-Board SMD PCB Terminal Block; 0.75 mm²; Pin spacing 6.5 mm; 2-pole; Push-in CAGE CLAMP®; in tape-and-reel packaging; white
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | PCB Terminal Blocks and Pluggable Connectors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 2070-452/998-406 be shipped?
2070-452/998-406 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 2070-452/998-406 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 2070-452/998-406 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2070-452/998-406, subject to availability and destination.
<h2>PCB terminal block, 2070 Series, 0 °conductor entry to board</h2><br/><br/>Connect conductors quickly and securely with this PCB terminal block (item number 2070-452/998-406). It is a universal connector that can be used practically anywhere, e.g., as a pluggable PCB connector, panel feedthrough header, connector for rail-mount terminal blocks, or a floating connector for different mounting methods. Strip lengths must be between 8 and 10 mm when connecting conductors to this PCB terminal block. Featuring one conductor terminal along with Push-in CAGE CLAMP®, this connector delivers reliable performance. Push-in CAGE CLAMP® connection technology is ideal for connecting all conductor types. Both solid and fine-stranded conductors with ferrules can be inserted without the need for tools—all thanks to its pluggable design. Dimensions: (11.8 x 7.45 x 22.2) mm (width x height x depth). Depending on the conductor type, this PCB terminal block is ideal for conductor cross sections ranging from 0.2 mm² to 0.75 mm².<br/><br/><h3></h3><br/><br/>The contact surface is coated with tin. This PCB terminal block is operated with an operating tool. SMD is used to assemble the PCB terminal block. The conductor is designed to be inserted at a 0° angle..<br/>
Specifications
Notes
| Note | Depending on reflow soldering temperatures and times, color deviations may occur. These deviations will have no impact on functionality. |
| Variants: | Reel diameter of tape-and-reel packaging: 381 mm, Other versions (or variants) can be requested from WAGO Sales or configured at https://configurator.wago.com/. |
Electrical data - Ratings per IEC/EN
| Ratings | Electrical data for FR4 PCB type |
| Ratings per | IEC/EN 60664-1 |
| Nominal voltage (III/3) | 320 V |
| Rated impulse withstand voltage (III / 3) | 4 kV |
| Rated voltage (III/2) | 320 V |
| Rated impulse withstand voltage (III/2) | 4 kV |
| Nominal voltage (II/2) | 630 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 9 A |
| Legend (ratings) | (III / 2) ≙ Overvoltage category III / Pollution degree 2 |
| Ratings | Electrical data for FR4 PCB type / Electrical data for FR4 PCB type / Electrical data for FR4 PCB type |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 320 V / 320 V / 630 V |
| Rated impulse withstand voltage | 4 kV / 4 kV / 4 kV |
| Rated current | 9 A / 9 A / 9 A |
Electrical data - Ratings per IEC/EN 2
| Ratings | Electrical data for metal-core PCBs |
| Ratings per | IEC/EN 60664-1 |
| Rated voltage (III / 3) | 200 V |
| Rated impulse withstand voltage (III/3) | 4 kV |
| Rated voltage (III / 2) | 320 V |
| Rated impulse withstand voltage (III/2) | 4 kV |
| Rated voltage (II/2) | 500 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 9 A |
| Ratings | Electrical data for metal-core PCBs / Electrical data for metal-core PCBs / Electrical data for metal-core PCBs |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 200 V / 320 V / 500 V |
| Rated impulse withstand voltage | 4 kV / 4 kV / 4 kV |
| Rated current | 9 A / 9 A / 9 A |
Electrical data - Ratings per UL 1977
| Rated voltage (UL 1977) | 600 V |
| Rated current UL 1977 | 9 A |
| Approvals per | UL 1977 |
| Rated voltage | 600 V |
| Rated current | 9 A |
Connection data
| Clamping units | 2 |
| Total number of potentials | 2 |
| Number of connection types | 1 |
| Number of levels | 1 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
| Actuation type | Operating tool |
| Solid conductor | 0.2 … 0.75 mm² / 24 … 18 AWG |
| Fine-stranded conductor | 0.2 … 0.75 mm² / 24 … 18 AWG |
| Strip length | 8 … 10 mm / 0.31 … 0.39 inches |
| Conductor connection direction to PCB | 0 ° |
| Pole number | 2 |
Physical data
| Pin spacing | 6.5 mm / 0.256 inches |
| Width | 11.8 mm / 0.465 inches |
| Height | 7.45 mm / 0.293 inches |
| Depth | 22.2 mm / 0.874 inches |
| Reel diameter of tape-and-reel packaging | 330 mm |
| Tape width | 44 mm |
| PCB thickness (max.) | 2.4 mm |
Mechanical data
| Design | without Cover |
| Mounting type | Through-board |
PCB contact
| PCB contact | SMD |
| Solder pin arrangement | Over the entire terminal strip (in-line) |
| Number of solder pins per potential | 2 |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | white |
| Material group | I |
| Insulation material (main housing) | Polyphthalamide (PPA GF) |
| Flammability class per UL94 | V0 |
| Contact material | Copper alloy |
| Contact plating | Tin |
| Weight | 1.2 g |
Environmental requirements
| Limit temperature range | -60 … +105 °C |
Environmental requirements - Environmental Testing
| Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
| Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
| Spectrum/Mounting location | Service life test, Category 1, Class A/B |
| Functional test with noise-like oscillations | Test passed according to Section 8 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.101g (highest test level used for all axes) |
| Test duration per axis | 10 min. |
| Test directions | X, Y and Z axes |
| Monitoring of contact faults and interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed |
| Simulated service life test through increased levels of noise-like oscillations | Test passed according to Section 9 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.572g (highest test level used for all axes) |
| Test duration per axis | 5 h |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard |
| Shock pulse form | Half sine |
| Acceleration | 5g (highest test level used for all axes) |
| Shock duration | 30 ms |
| Number of shocks (per axis) | 3 pos. und 3 neg. |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Vibration and shock stress for rolling stock equipment | Passed |
Commercial data
| PU (SPU) | 2385 (477) pcs |
| Packaging type | box |
| Country of origin | CH |
| GTIN | 4055143645171 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121409 |
| eCl@ss 10.0 | 27-14-11-06 |
| eCl@ss 9.0 | 27-14-11-06 |
| ETIM 9.0 | EC001284 |
| ETIM 10.0 | EC001284 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |