Siemens 3SU1400-1AA10-3EA0-Z X90 – Contact module with 2 contact elements, 2 NC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.02 kg |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can 3SU1400-1AA10-3EA0-Z X90 be shipped?
3SU1400-1AA10-3EA0-Z X90 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 3SU1400-1AA10-3EA0-Z X90 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 3SU1400-1AA10-3EA0-Z X90 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3SU1400-1AA10-3EA0-Z X90, subject to availability and destination.
Contact module with 2 contact elements, 2 NC, spring-type terminal, for front plate mounting, Z=150-unit packaging
Specifications
Contact block/ lampholder
| socket design | other |
General technical data
| product function positive opening | Yes |
| insulation voltage rated value | 500 V |
| degree of pollution | 3 |
| type of voltage – of the operating voltage | AC/DC |
| type of voltage – of the input voltage | AC/DC |
| surge voltage resistance rated value | 6 kV |
| protection class IP – of the enclosure | IP40 |
| protection class IP – of the terminal | IP20 |
| shock resistance – according to IEC 60068-2-27 | sinusoidal half-wave 15 g / 11 ms |
| shock resistance – for railway applications according to EN 61373 | Category 1, Class B |
| vibration resistance – according to IEC 60068-2-6 | 10 ... 500 Hz: 5 g |
| vibration resistance – for railway applications according to EN 61373 | Category 1, Class B |
| operating frequency maximum | 3 600 1/h |
| mechanical service life (operating cycles) typical | 10 000 000 |
| electrical endurance (operating cycles) typical | 10 000 000 |
| thermal current | 10 A |
| reference code according to IEC 81346-2 | S |
| continuous current of the C characteristic MCB | 10 A |
| Substance Prohibitance (day/month/year) | 10/01/2014 |
| Net Weight | 17 g |
| at AC – — at 50 Hz rated value | 5 ... 500 V |
| at AC – — at 60 Hz rated value | 5 ... 500 V |
| at AC – at DC rated value | 5 ... 500 V |
Power Electronics
| contact reliability | One maloperation per 100 million (17 V, 5 mA), one maloperation per 10 million (5 V, 1 mA) |
Auxiliary circuit
| design of the contact of auxiliary contacts | Silver alloy |
| number of NC contacts for auxiliary contacts | 2 |
| lagging switching | 0 |
| number of NO contacts for auxiliary contacts | 0 |
| leading contact | 0 |
| operational current at AC-12 – at 24 V rated value | 10 A |
| operational current at AC-12 – at 48 V rated value | 10 A |
| operational current at AC-12 – at 110 V rated value | 10 A |
| operational current at AC-12 – at 230 V rated value | 8 A |
| operational current at AC-12 – at 400 V rated value | 8 A |
| operational current at AC-15 – at 24 V rated value | 6 A |
| operational current at AC-15 – at 48 V rated value | 6 A |
| operational current at AC-15 – at 110 V rated value | 6 A |
| operational current at AC-15 – at 230 V rated value | 6 A |
| operational current at AC-15 – at 400 V rated value | 3 A |
| operational current at AC-15 – at 500 V rated value | 1.4 A |
| operational current at DC-12 – at 24 V rated value | 10 A |
| operational current at DC-12 – at 48 V rated value | 5 A |
| operational current at DC-12 – at 110 V rated value | 2.5 A |
| operational current at DC-12 – at 230 V rated value | 1 A |
| operational current at DC-12 – at 400 V rated value | 0.3 A |
| operational current at DC-12 – at 500 V rated value | 0.3 A |
| operational current at DC-13 – at 24 V rated value | 3 A |
| operational current at DC-13 – at 48 V rated value | 1.5 A |
| operational current at DC-13 – at 110 V rated value | 0.7 A |
| operational current at DC-13 – at 230 V rated value | 0.3 A |
| operational current at DC-13 – at 400 V rated value | 0.1 A |
| operational current at DC-13 – at 500 V rated value | 0.1 A |
Connections/ Terminals
| type of electrical connection | spring-loaded terminals |
| type of connectable conductor cross-sections – solid without core end processing | 2x (0.25 ... 1.5 mm²) |
| type of connectable conductor cross-sections – finely stranded with core end processing | 2x (0.25 ... 0.75 mm²) |
| type of connectable conductor cross-sections – finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| type of connectable conductor cross-sections – for AWG cables | 2x (24 ... 16) |
Ambient conditions
| ambient temperature – during operation | -25 ... +70 °C |
| ambient temperature – during storage | -40 ... +80 °C |
| environmental category during operation according to IEC 60721 | 3M6, 3S2, 3B2, 3C3 (without salt spray), 3K6 (with relative humidity of 10 ... 95%, no condensation in operation permitted) |
Installation/ mounting/ dimensions
| fastening method | front plate mounting |
| of modules and accessories | Front plate mounting |
| height | 36 mm |
| width | 9.8 mm |
| depth | 49.7 mm |
| suitability for integration – plastic enclosure | No |
| suitability for integration – metal enclosure | No |
Environmental footprint
| Environmental Product Declaration(EPD) | Yes |
| global warming potential [CO2 eq] total | 0.787 kg |
| global warming potential [CO2 eq] during manufacturing | 0.566 kg |
| global warming potential [CO2 eq] during operation | 0.235 kg |
| global warming potential [CO2 eq] after end of life | -0.015 kg |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet 3SU1400-1AA10-3EA0 |
More Siemens parts
Available on requestSiemens 3SU1400-1AA10-1EA0-Z X90 – Contact module with 2 contact elements, 2NC, screw terminal
Available on requestSiemens 3SU1400-1AA10-1FA0-Z X90 – Contact module with 2 contact elements, 1 NO+1 NC
Available on requestSiemens 3SU1400-1AA10-1FA0-Z Y19 – Contact module with 2 contact elements, 1 NO+1 NC
Available on requestSiemens 3SU1400-1AA10-1GA0 – Contact module with 2 contact elements
Available on requestSiemens 3SU1400-1AA10-3EA0-Z Y19 – Contact module with 2 contact elements, 2 NC
Available on requestSiemens 3SU1400-1AA10-3FA0 – Contact module with 2 contact elements, 1 NO+1 NC
Available on requestSiemens 3SU1400-1AA10-3NA0-Z Y19 – Contact module with 2 contact elements, 2 NO
Available on requestSiemens 3SU1400-1AA10-3PA0 – Contact module with 2 contact elements, 2 NC