Sick WLG12-G137
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | WLG |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can WLG12-G137 be shipped?
WLG12-G137 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up WLG12-G137 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for WLG12-G137 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for WLG12-G137, subject to availability and destination.
Automation light grids | WLG | WLG12-G137 | Beam separation: 12.5 mm | Operating range: 1.5 m | Detection height: 87.5 mm | Length of cable: 2 m | Response time: 0.6 ms
Specifications
Features
| Sensor principle | Photoelectric retro-reflective sensor |
| Minimum detectable object (MDO) | Parallel beam, 6 mm ... 12.5 mm |
| Beam separation | 12.5Â mm |
| Number of beams | 8 |
| Detection height | 87.5Â mm |
| Resolution (adjustable) | 6 mm ... 12.5 mm 1) |
Mechanics/electronics
| Wave length | 650Â nm |
| Supply voltage Vs | DC 18Â VÂ ... 30Â VÂ 1) |
| Power consumption sender | 80Â mA |
| Ripple | <Â 5Â Vpp |
| Output current Imax. | â¤Â 100 mA |
| Output load, capacitive | 100Â nF |
| Output load, Inductive | 1Â H |
| Initialization time | 0.6Â s |
| Switching output | 8Â x PNPÂ 2)Â 3) |
| Output mode | Q dark switching 4) |
| Teach-in input | PNP |
| Dimensions (W x H x D) | 62 mm x 106 mm x 46.6 mm |
| Connection type | Cable, 2Â m |
| Housing material | Plastic |
| Indication | LED |
| Enclosure rating | IP67 |
| Circuit protection | UV connections, reverse polarity protectedOutput Q short-circuit protectedInterference pulse suppression |
| Protection class | II |
| Weight | 230Â g |
| Front screen | PMMA |
Performance
| Maximum range | 1.5Â m |
| Minimum range | ⥠100 mm |
| Operating range | 1.5Â m |
| Response time | Parallel beam, 0.6 ms 1) |
Ambient data
| Shock resistance | 10 g / DIN EN 60068-2-29 / 16 ms |
| Vibration resistance | 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) |
| EMC | ENÂ 60947-5-2 |
| Ambient operating temperature | â25 °C ... +55 °C |
| Ambient temperature, storage | â20 °C ... +70 °C |
Certificates
| EU declaration of conformity | â |
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| Moroccan declaration of conformity | â |
| China RoHS | â |
Classifications
| ECLASS 5.0 | 27270910 |
| ECLASS 5.1.4 | 27270910 |
| ECLASS 6.0 | 27270910 |
| ECLASS 6.2 | 27270910 |
| ECLASS 7.0 | 27270910 |
| ECLASS 8.0 | 27270910 |
| ECLASS 8.1 | 27270910 |
| ECLASS 9.0 | 27270910 |
| ECLASS 10.0 | 27270910 |
| ECLASS 11.0 | 27270910 |
| ECLASS 12.0 | 27270910 |
| ETIM 5.0 | EC002549 |
| ETIM 6.0 | EC002549 |
| ETIM 7.0 | EC002549 |
| ETIM 8.0 | EC002549 |
| UNSPSC 16.0901 | 39121528 |