Sick SIG200-0A0512200
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | SIG200 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SIG200-0A0512200 be shipped?
SIG200-0A0512200 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SIG200-0A0512200 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SIG200-0A0512200 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SIG200-0A0512200, subject to availability and destination.
Network devices | SIG200 | SIG200-0A0512200 | Product category: IO-Link Master | Communication interface: IO-LinkUSBEthernetEtherNet/IP™REST API | Supported products: IO-Link DevicesBinary actuatorsBinary switching sensors | Scope of delivery: SIG200-0A05122004x blind plugs (M12) on port S2, S3, S4, P21x blind plug (M8) on port CONFIGMarking labelsQuickstart | Further functions: Web server integratedUSB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICKLogic editor is available for easy configuration of logic functions
Specifications
Features
| Product category | IO-Link Master |
| Supported products | IO-Link DevicesBinary actuatorsBinary switching sensors |
| Further functions | Web server integratedUSB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICKLogic editor is available for easy configuration of logic functions |
| Items supplied | SIG200-0A0512200, 4x blind plugs (M12) on port S2, S3, S4, P2, 1x blind plug (M8) on port CONFIG, Marking labels, quickstart |
Mechanics/electronics
| IO-Link | 4 x M12, 5-pin female connector, A-coded |
| Power | 1 x M12, 4-pin plug, A-coded |
| CONFIG | 1 x M8, 4-pin female connector, USB 2.0 (USB-A) |
| Ethernet | 2 x M12, 4-pin female connector, D-coded |
| Supply voltage | 10Â VÂ DCÂ ... 30Â VÂ DCÂ 1) |
| Current consumption | â¤Â 175 mA, â¤Â 3,000 mA, At supply voltage 24 V DC 2) 3) |
| Optical indicators | 4Â LED green (To the IO-Link ports, Pin4 (C/DI/DO))4Â LED yellow (To the IO-Link ports, Pin2 (DI))2Â LED green (To the Ethernet ports)1Â LED green (For the Power Port)1Â LED dual-color (For module status communication)1Â LED green (For network status communication) |
| S1-S4 pin 1 voltage supply | â¤Â 500 mA (VH ⥠VUS - 3 V) 4) |
| S1-S4 pin 4 output current | â¤Â 200 mA (Type 3 IEC 61131-2) 4) |
| Power Port pin 4Â output voltage HIGH | Type 1Â IECÂ 61131-2 |
| S1-S4 pin 2Â input voltage | Type 3Â IECÂ 61131-2 |
| S1-S4 pin 4Â input voltage | Type 1Â IECÂ 61131-2 |
| Enclosure rating | IP67 |
| Protection class | III |
| Housing material | Zinc |
| Housing color | Light blue/Black |
| Weight | 520Â g |
| Dimensions (L x W x H) | 213.9 mm x 57 mm x 38.3 mm |
| UL File No. | E497722 |
Interfaces
| Communication interface | IO-Link, USB, Ethernet, EtherNet/IPâ¢, REST API |
| Logic editor | â |
| Web server | â |
| Function | The SIG200 Sensor Integration Gateway is an IO-Link master with 4Â configurable ports to which IO-Link device as well as binary switching sensors and actuators can be connected. The gateway data is made available to a PLC or cloud application via the REST API.SIG200 can also be operated as a standalone system by directly configuring simple logic functions across several connected devices via the SOPAS ET user interface. |
| IO-Link version | V1.1, V1.0 |
| Port Class | A |
| Number of IO-Link ports | 4 |
| Transmission type | COM1, COM2, COM3 |
| Operator interfaces | SOPAS ET, the engineering tool for configuration via USB, Additionally, the SIG200 can be configured via the integrated webserver. Default IPÂ adress: 192.168.0.1 |
| MAC address | See product label |
| Number of inputs | Max. 8Â x PNP, type 1Â or 4Â x IO-Link |
| Number of outputs | Max. 4Â x PNP |
| Max. Output frequency | 50Â Hz |
| S1-S4 | 4Â configurable portsPin4 can be used in one of the available port modes: IO-Link, digital input or digital output. An additional digital input signal can be connected using Pin2. (SOPAS ET can be downloaded for free from www.sick.com) |
| LINK/ACT 1Â & 2 | Two Ethernet ports are provided for the network connection |
| CONFIG | Port for configuration via USB with SOPAS ET (SOPAS ET can be downloaded for free from www.sick.com) |
| Initialization time after switch on | 70s (plus additional time for IODD installation) |
Ambient data
| Ambient operating temperature | â40 °C ... +55 °C 1) |
| Ambient temperature, storage | â40 °C ... +75 °C 1) |
| Electromagnetic compatibility (EMC) | ENÂ 61000-6-2:2005-08 / ENÂ 61000-6-3:2007-01 |
| Shock load | ENÂ 60068-2-6 |
Certificates
| EU declaration of conformity | â |
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| Moroccan declaration of conformity | â |
| China RoHS | â |
| cULus certificate | â |
| IO-Link certificate | â |
| Profinet certificate | â |
Classifications
| ECLASS 5.0 | 27242208 |
| ECLASS 5.1.4 | 27242608 |
| ECLASS 6.0 | 27242608 |
| ECLASS 6.2 | 27242608 |
| ECLASS 7.0 | 27242608 |
| ECLASS 8.0 | 27242608 |
| ECLASS 8.1 | 27242608 |
| ECLASS 9.0 | 27242608 |
| ECLASS 10.0 | 27242608 |
| ECLASS 11.0 | 27242608 |
| ECLASS 12.0 | 27242608 |
| ETIM 5.0 | EC001604 |
| ETIM 6.0 | EC001604 |
| ETIM 7.0 | EC001604 |
| ETIM 8.0 | EC001604 |
| UNSPSC 16.0901 | 32151705 |