Sick airWiper Kit outdoorScan3 Core I/O
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | outdoorScan3 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can airWiper Kit outdoorScan3 Core I/O be shipped?
airWiper Kit outdoorScan3 Core I/O is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up airWiper Kit outdoorScan3 Core I/O in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for airWiper Kit outdoorScan3 Core I/O and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for airWiper Kit outdoorScan3 Core I/O, subject to availability and destination.
Safety laser scanners | outdoorScan3 | airWiper Kit outdoorScan3 Core I/O | Product version: outdoorScan3 Core I/O | Model: Sensor kit for compressed air cleaning, including system plug | Integration in the control system: Local inputs and outputs (I/O) | Protective field range: 4 m | Scanning angle: 275° | Number of fields: 8 | Connection type: M12
Specifications
Features
| Product version | outdoorScan3 Core I/O |
| Model | Sensor kit for compressed air cleaning, including system plug |
| Application | Â 1)Outdoor |
| Compressed air cleaning | Possible |
| Operating medium | Compressed air |
| Purity class | ISOÂ 8573-1 [7:4:4] |
| Input pressure | Typ. 400 kPa (200 kPa ... 600 kPa, 2.0 bar ... 6.0 bar) |
| Temperature of compressed air | â¤Â +50 °C |
| Protective field range | 4Â m |
| Warning field range | 40Â m |
| Number of simultaneously monitored fields | ⤠4 2) 3) |
| Number of fields | 8Â 4) |
| Number of monitoring cases | 2 |
| Scanning angle | 275° |
| Resolution (can be configured) | 50Â mm70Â mm |
| Angular resolution | 0.39° |
| Response time | 90Â ms |
| Protective field supplement | 65Â mm |
Safety-related parameters
| Type | Type 3Â (IECÂ 61496) |
| Safety integrity level | SIL 2Â (IECÂ 61508) |
| Category | Category 3Â (ENÂ ISOÂ 13849) |
| Performance level | PL d (EN ISO 13849) |
| Performance class SRS/SRSS | Performance class D (IEC/TS 62998) |
| PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 |
| TM (mission time) | 20Â years (ENÂ ISOÂ 13849) |
| Safe state in the event of a fault | In each OSSD pair, at least one OSSD is in the OFF state. |
Functions
| Restart interlock | â |
| External device monitoring (EDM) | â |
| Multiple sampling | â |
| Monitoring case switching | â |
| Simultaneous monitoring | â |
| Static protective field switching | â |
| Integrated configuration memory | â |
| Measured data output | None |
Interfaces
| Compressed air connections | 4Â x push-pull connection for compressed air hose (Ã 4Â mm), M5 male thread |
| Connection type | Male connector, M12, 8Â pin, A-coded (common male connector for power supply and inputs and outputs) |
| Universal I/Osâ | 3 |
| OSSD pairs | 1 |
| Configuration method | PC with Safety Designer (Configuration and Diagnostic Software) |
| Configuration and diagnostics interface | USB 2.0, Mini-USB |
| Display elements | Graphic color display, LEDs |
Electronics
| Protection class | III (ENÂ 61140) |
| Supply voltage Vs | 24Â VÂ DC (16.8Â VÂ DCÂ ... 30Â VÂ DC) |
| Power consumption typical | 7Â W (without output load) |
Mechanics
| Dimensions (W x H x D) | 140.6 mm x 135.1 mm x 127.6 mm |
| Weight | 1.3Â kg |
| Housing material | Aluminum |
| Housing color | RAL 2004Â (pure orange), RAL 9005Â (black) |
| Optics cover material | Polycarbonate |
| Optics cover surface finish | Outside with scratch-resistant coating |
| Material of the airWiper | Aluminum (anodised) |
Ambient data
| Enclosure rating | IP65 (IECÂ 60529) |
| Halogen light | 12,000Â lx (IECÂ 61496-3) |
| Sunlight | 40,000Â lx (IECÂ 61496-3) |
| Ambient operating temperature | â25 °C ... +50 °C |
| Storage temperature | â25 °C ... +70 °C |
| Rain | 10 mm/h 1) |
| Snowfall | 3 mm/h SWE, Snow Water Equivalent 1) |
| Fog | 50Â m (MOR, Meteorological Optical Range)Â 1) |
| Vibration resistance | IECÂ 60068-2-6, IECÂ 60068-2-64, IECÂ 60721-3-5, IECÂ TR 60721-4-3, IECÂ 61496-1, IECÂ 61496-3 |
| Class | 5M1 (IECÂ 60721-3-5) |
| Shock resistance | IECÂ 60068-2-27, IECÂ 60721-3-5, IECÂ TR 60721-4-3, IECÂ 61496-1, IECÂ 61496-3 |
| Class | 5M1 (IECÂ 60721-3-5) |
| Continuous shock | 100 m/s², 16 ms |
| EMC | IECÂ 61496-1, IECÂ 61000-6-2, IECÂ 61000-6-4 |
Other information
| Type of light | Pulsed laser diode |
| Wave length | 845Â nm |
| Detectable remission factor | 1.8% to several 1000% |
| Laser class | 1Â (21Â CFR 1040.10Â and 1040.11, IECÂ 60825-1) |
Certificates
| EU declaration of conformity | â |
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| China RoHS | â |
| cULus certificate | â |
| EC-Type-Examination approval | â |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | â |
Classifications
| ECLASS 5.0 | 27272705 |
| ECLASS 5.1.4 | 27272705 |
| ECLASS 6.0 | 27272705 |
| ECLASS 6.2 | 27272705 |
| ECLASS 7.0 | 27272705 |
| ECLASS 8.0 | 27272705 |
| ECLASS 8.1 | 27272705 |
| ECLASS 9.0 | 27272705 |
| ECLASS 10.0 | 27272705 |
| ECLASS 11.0 | 27272705 |
| ECLASS 12.0 | 27272705 |
| ETIM 5.0 | EC002550 |
| ETIM 6.0 | EC002550 |
| ETIM 7.0 | EC002550 |
| ETIM 8.0 | EC002550 |
| UNSPSC 16.0901 | 39121528 |