Available on request

APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V

MPN: SYA8K16P · Brand: Schneider Electric
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAPC Symmetra
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)
Weight219.55 kg

Shipping & availability

When can SYA8K16P be shipped?

SYA8K16P is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SYA8K16P in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SYA8K16P and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SYA8K16P, subject to availability and destination.

Specifications

Specifications

Lead timeUsually in Stock
Max. Capacity Used
Main Input Voltage208 V AC 1 phase, 120 V AC 1 phase, 240 V AC 1 phase
Input voltage240 V
Input harmonic distortionLess than 7 % for full load
Cos phi0.98
Input voltage limits96...138 V line to neutral
Number of input connectors1 hard wire 4-wire (2P + N + E)
Network frequency45...65 Hz auto-sensing
Output voltage240 V
Rated power in W6400 W
rated power in VA8000 VA
Output connector typeHard wire 4-wire (2P + N + E) for 1 zone(s)
Bypass typeInternal bypass (automatic and manual)
Crest factorUp to 5 : 1
Harmonic distortionLess than 5 % at full load
Maximum configurable power in VA16000 VA
Maximum configurable power in W12800 W
Maximum output current37 A
UPS typeOn-Line
Wave typeSine wave
Output frequency47...63 Hz sync to mains, 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised, 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Additional informationConfigurable for 120/208 or 120/240 output voltage
Battery typeLead-acid battery
Control panelMultifunction LCD status and control console
Emergency power offYes
Free slots1
Preinstalled deviceNetwork management card 2 with environmental monitoring
AlarmAudible and visible alarms : prioritized by severity
UPS connectivitySerial port, Pre-installed network management card 3, Available expansion slot
ColourBlack, Silver
Height937 mm
Width483 mm
Depth726 mm
Net weight219.55 kg
Mounting locationFront
Mounting preferenceNo preference
Mounting modeTower
Two post mountable0
USB compatibleNo
Provided equipmentCD with software, Installation guide, User manual, Web/SNMP management card
Number of power module filled slots2
Number of power module free slots3
Additional specification4kVA power increments
RedundantYes
Range of productSymmetra LX
Product or component typeUninterruptible power supply (UPS)
Performance multiplier1
Value multiplier1
Size UPS versionInternetworking, Server, Telecom
Curve equationEfficiency
Curve fixed loss0.0305
Curve load maximum100 %
Curve load minimum4 %
Curve proportional loss0.0622
Curve square loss0.0196
Curve test cond IDCurve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
Curve X-axis maximum100 %
Curve X-axis minimum0 %
Curve X-axis titleLoad
Curve X-axis unitsPercentage
Curve Y-axis maximum100 %
Curve Y-axis minimum50 %
Curve Y-axis titleEfficiency
Curve Y-axis unitsPercentage
Graph display1
Show note OP temperatureNo
UPS sizeL
Product certificationsCSA
StandardsFCC part 15 class A, UL 1778
Ambient air temperature for operation0…40 °C
Ambient air temperature for storage-15…45 °C
Storage altitude0…4572 m
Relative humidity0…95 %
Storage Relative Humidity0…95 %
Acoustic level62 dBA
Heat dissipation4995 Btu/h
Operating altitude0...10000 ft
Run TimeView Runtime Graph
EfficiencyView Efficiency Graph
Extended runtime1
Number of battery filled slots2
Number of battery free slots2
Battery recharge time3 h
Battery life3…5 year(s)
Battery charger power574 W rated
Number of tare power200 W
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height118.1 cm
Package 1 Width99.7 cm
Package 1 Length59.9 cm
Package 1 Weight236.82 kg
Warranty (in months)24
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Schneider Electric parts

Schneider Electric Tac xenta-401 UsedUsedSchneider Electric Tac xenta-401 Used
MPN: Tac xenta-401 · Schneider Electric
€94.34
View details
Schneider Electric LC1D80AKUE New open boxNewSchneider Electric LC1D80AKUE New open box
MPN: LC1D80AKUE · Schneider Electric
€401.74
View details
Schneider Electric A9F94101 New without boxNewSchneider Electric A9F94101 New without box
MPN: A9F94101 · Schneider Electric
€116.60
View details
Schneider Electric BMXNoE0100 UsedUsedSchneider Electric BMXNoE0100 Used
MPN: BMXNoE0100 · Schneider Electric
€285.14
View details