voltage control relay, Harmony Control Relays, 8A, 2CO, overvoltage or undervoltage detection, 0.05…5V AC DC, 24…240V AC DC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Harmony Control Relays |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.11 kg |
Shipping & availability
When can RM22UA31MR be shipped?
RM22UA31MR is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up RM22UA31MR in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for RM22UA31MR and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for RM22UA31MR, subject to availability and destination.
This Harmony RM22-UA relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Specifications
Specifications
| Range of product | Harmony Control Relays |
| Relay type | Voltage control relay |
| Product or component type | Voltage control relay |
| Network number of phases | 1 phase |
| Supply circuit type | DC |
| Relay name | RM22UA |
| Relay monitored parameters | Undervoltage and overvoltage in window mode, Overvoltage or undervoltage detection |
| time delay | Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Switching capacity in VA | 2000 VA |
| Measurement range | 0.05...5 V AC/DC |
| Contacts type and composition | 2 C/O |
| Reset time | 1500 ms at maximum voltage |
| Maximum switching voltage | 250 V AC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 8 A AC |
| Supply voltage limits | 20.4…264 V AC/DC |
| Power consumption in VA | 3.5 VA AC |
| Maximum power consumption in W | 1.5 W DC |
| Immunity to microbreaks | 10 ms |
| Resistance across terminals | 30 kOhm at E2-M terminals, 5 kOhm at E1-M terminals, 50 kOhm at E3-M terminals |
| Output contacts | 2 C/O |
| nominal output current | 8 A |
| Hysteresis | 3 % fixed of full scale for window mode, 5…50 % adjustable of threshold setting |
| delay at power up | 600 ms |
| Maximum measuring cycle | 100 ms measurement cycle as true rms value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit, +/- 2 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation, 0.05 %/°C with temperature variation |
| Response time | <= 500 ms |
| Insulation resistance | > 100 MOhm at 500 V DC |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation | Between supply and measurement |
| Connections - terminals | Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end, Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end, Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end, Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 10000000 cycles |
| Utilisation category | AC-15 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1, AC-1 conforming to IEC 60947-4-1, DC-1 conforming to IEC 60947-4-1 |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Safety reliability data | MTTFd = 308.2 years, B10d = 290000 |
| Contacts material | Cadmium free |
| Control type | With test button |
| Width | 22.5 mm |
| Net weight | 0.11 kg |
| Electromagnetic compatibility | Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1, Immunity for industrial environments conforming to IEC 61000-6-2, Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3, Emission standard for industrial environments conforming to IEC 61000-6-4, Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2, Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2, Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4, Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5, Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5, Conducted and radiated emissions class B group 1 conforming to CISPR 11, Conducted and radiated emissions class B conforming to CISPR 22 |
| Ambient air temperature for operation | -20…50 °C at 60 Hz, -20…60 °C at 50 Hz |
| Standards | IEC 60255-1 |
| Product certifications | CE, CSA, RCM, GL, CCC, EAC, UL |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6, 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6, 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6, 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27, 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front panel) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Dielectric test voltage | 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.600 cm |
| Package 1 Width | 8.200 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 121.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.292 kg |
| Warranty (in months) | 18 |