Available on request

Pepperl Fuchs VIM62PP-E1V16-0HE-I420V14

MPN: VIM62PP-E1V16-0HE-I420V14 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryVibration Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can VIM62PP-E1V16-0HE-I420V14 be shipped?

VIM62PP-E1V16-0HE-I420V14 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VIM62PP-E1V16-0HE-I420V14 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VIM62PP-E1V16-0HE-I420V14 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VIM62PP-E1V16-0HE-I420V14, subject to availability and destination.

Vibration sensor. Vibration sensor with analog current output, increased temperature resistance, suitable for Class I/II and Division 2, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current <BR>output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. <BR>adapters providing field wiring on request, Hazardous Location: E106378. Type: Vibration sensor. Measuring technology: MEMS. Series: Performance Plus Line. Measured variable: Vibration velocity. Measuring range: . Vibration velocityv-rms0 ... 16 mm/s: v-rms. Vibration velocity: 0 ... 16 mm/s. Measurement accuracy: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Frequency range: 10 ... 1000 Hz. Averaging time: for v-rms: 2 s. Fusing: external fuse is required: 3 A , semi-time-lag , 30 V DC. Operating voltage: 10 ... 30 V DC. Current consumption: max. 25 mA. Power consumption: max. 750 mW. Time delay before availability: 10 s (rms filter is calculated intially with measurement data before they are available at the output). Surge protection: up to 2 kV. Output type: analog output, current output of the vibration variable. Output current: 4 ... 20 mA. Load resistor: ≤ 500 Ω. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz. Vibration evaluation: DIN ISO 10816/20816. UL approval: . Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestHazardous LocationE106378Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)Control drawing116-0492: . Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request. Hazardous Location: E106378. Maximum permissible ambient temperature: max. 60 °C (max. 140 °F). Control drawing: 116-0492. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Measuring head temperature: -40 ... 125 °C (-40 ... 257 °F) directly at the mounting point. Storage temperature: -40 ... 60 °C (-40 ... 140 °F). Connection type: plug. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state. Connector: . ThreadingM12Number of pins4: . Threading: M12. Number of pins: 4. Mass: approx. 200 g. Dimensions: . Length82.35 mmDiameter31 mm: . Length: 82.35 mm. Diameter: 31 mm. Use in the hazardous area: see instruction manuals Only use accessories specified by the manufacturer.

Specifications

General specifications

TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Plus Line
Measured variableVibration velocity
Measuring range
Vibration velocityv-rms0 ... 16 mm/sv-rms
Vibration velocity0 ... 16 mm/s
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s

Electrical specifications

Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage10 ... 30 V DC
Current consumptionmax. 25 mA
Power consumptionmax. 750 mW
Time delay before availability10 s (rms filter is calculated intially with measurement data before they are available at the output)
Surge protectionup to 2 kV

Output 1

Output typeanalog output, current output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω

Standard conformity

Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816

Approvals and certificates

UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestHazardous LocationE106378Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)Control drawing116-0492
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request
Hazardous LocationE106378
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Control drawing116-0492

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Measuring head temperature-40 ... 125 °C (-40 ... 257 °F) directly at the mounting point
Storage temperature-40 ... 60 °C (-40 ... 140 °F)

Mechanical specifications

Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12Number of pins4
ThreadingM12
Number of pins4
Massapprox. 200 g
Dimensions
Length82.35 mmDiameter31 mm
Length82.35 mm
Diameter31 mm

General information

Use in the hazardous areasee instruction manuals Only use accessories specified by the manufacturer.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote