Pepperl Fuchs V1-W-N-BU2M-PUR-N1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Sensor-Actuator Cables |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can V1-W-N-BU2M-PUR-N1 be shipped?
V1-W-N-BU2M-PUR-N1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up V1-W-N-BU2M-PUR-N1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for V1-W-N-BU2M-PUR-N1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for V1-W-N-BU2M-PUR-N1, subject to availability and destination.
Cable connector, NAMUR. Female cordset single-ended M12 angled A-coded, 2-pin, PUR cable blue, Ex certified. Connector 1: . ConnectionsocketConstruction typeM12StyleangledLockingscrew connectionNumber of pins2CodingA-coded: . Connection: socket. Construction type: M12. Style: angled. Locking: screw connection. Number of pins: 2. Coding: A-coded. Connector 2: . Connectioncable end: . Connection: cable end. Operating voltage: max. 250 V AC/DC. Operating current: max. 4 A. Resistance per unit length: max. 0.057 Ω/m. Capacitance per unit length: 102.4 nF/km. Inductance per unit length: 0.49 mH/km. Degree of protection: EN 60529. Plug connection: connector M12 x 1 : IEC 61076-2-101. Explosion protection: IEC 60079-0 , IEC 60079-11. Lead-free: RoHS directive 2011/65/EU. Ambient temperature: . Plug connector-40 ... 90 °C (-40 ... 194 °F)Cable, fixed installation-40 ... 80 °C (-40 ... 176 °F)Cable, flexing-20 ... 80 °C (-4 ... 176 °F): . Plug connector: -40 ... 90 °C (-40 ... 194 °F). Cable, fixed installation: -40 ... 80 °C (-40 ... 176 °F). Cable, flexing: -20 ... 80 °C (-4 ... 176 °F). Pollution degree: 3. Plug connector: . Tightening torque0.6 NmLoosening protectionintegratedTool installationstraight knurling and hexagon nut SW = 14 mmMating cyclesmin. 100: . Tightening torque: 0.6 Nm. Loosening protection: integrated. Tool installation: straight knurling and hexagon nut SW = 14 mm. Mating cycles: min. 100. Degree of protection: IP66 / IP68 / IP69. Cable: according to IEC/EN 60228 (DIN VDE 0295) class 6. Sheath diameter4.8 mmBending radius> 15 x cable diameter, movable installation > 10 x cable diameter, fixed installationSheath colorblue (similar to RAL 5015)Number of cores2Core cross section0.34 mm2Cores colorCore 1: brown Core 2: blueCore construction42 x 0.1 mm ∅LengthL2 mCable codeLi FY 11Y 2 x 0.34: . Sheath diameter: 4.8 mm. Bending radius: > 15 x cable diameter, movable installation > 10 x cable diameter, fixed installation. Sheath color: blue (similar to RAL 5015). Number of cores: 2. Core cross section: 0.34 mm2. Cores color: Core 1: brown Core 2: blue. Core construction: 42 x 0.1 mm ∅. Length: 2 m. Cable code: Li FY 11Y 2 x 0.34. Lead-free: yes. Plug connector: . Screw connectionZinc diecast, nickel-platedBodyTPU, blackSealFKMContact surfacegold plated (Au)FlammabilityV-2: . Screw connection: Zinc diecast, nickel-plated. Body: TPU, black. Seal: FKM. Contact surface: gold plated (Au). Flammability: V-2. Cable: . SheathingPUR based on polyetherCoresbare copper (Cu)Core insulationPVCFlammabilityHB: . Sheathing: PUR based on polyether. Cores: bare copper (Cu). Core insulation: PVC. Flammability: HB. EU-type examination certificate: TÜV 24 ATEX 9153X. Marking II 1G Ex ia IIC T6 Ga Ta = -25 °C ... +80 °C [exsign] II 1D Ex ia IIIC T200 85°C Da Ta = -25 °C ... +80 °CVoltageUimax. 30 VCurrentIimax. 1 APowerPifor II and IIIB gas groups: 1 W for IIIC gas group (depending on Tamb):40°C / 750 mW, 70 °C / 650 mW, 90 °C / 550 mWAmbient temperatureTamb-25 ... 80 °C (-13 ... 176 °F): . Marking: II 1G Ex ia IIC T6 Ga Ta = -25 °C ... +80 °C [exsign] II 1D Ex ia IIIC T200 85°C Da Ta = -25 °C ... +80 °C. Voltage: max. 30 V. Current: max. 1 A. Power: for II and IIIB gas groups: 1 W for IIIC gas group (depending on Tamb):40°C / 750 mW, 70 °C / 650 mW, 90 °C / 550 mW. Ambient temperature: -25 ... 80 °C (-13 ... 176 °F). IECEx approval: IECEx TUR 24.0043X. Cable marking sleeve: 1x PUR transparent , fixed to cable
Specifications
General specifications
| Connector 1 | |
| ConnectionsocketConstruction typeM12StyleangledLockingscrew connectionNumber of pins2CodingA-coded | Connection |
| Connection | socket |
| Construction type | M12 |
| Style | angled |
| Locking | screw connection |
| Number of pins | 2 |
| Coding | A-coded |
| Connector 2 | |
| Connectioncable end | Connection |
| Connection | cable end |
Electrical specifications
| Operating voltage | max. 250 V AC/DC UB |
| Operating current | max. 4 A IB |
| Resistance per unit length | max. 0.057 Ω/m R' |
| Capacitance per unit length | 102.4 nF/km C' |
| Inductance per unit length | 0.49 mH/km L' |
Conformity
| Degree of protection | EN 60529 |
| Plug connection | connector M12 x 1 : IEC 61076-2-101 |
| Explosion protection | IEC 60079-0 , IEC 60079-11 |
| Lead-free | RoHS directive 2011/65/EU |
Ambient conditions
| Ambient temperature | |
| Plug connector-40 ... 90 °C (-40 ... 194 °F)Cable, fixed installation-40 ... 80 °C (-40 ... 176 °F)Cable, flexing-20 ... 80 °C (-4 ... 176 °F) | Plug connector |
| Plug connector | -40 ... 90 °C (-40 ... 194 °F) |
| Cable, fixed installation | -40 ... 80 °C (-40 ... 176 °F) |
| Cable, flexing | -20 ... 80 °C (-4 ... 176 °F) |
| Pollution degree | 3 |
Mechanical specifications
| Plug connector | |
| Tightening torque0.6 NmLoosening protectionintegratedTool installationstraight knurling and hexagon nut SW = 14 mmMating cyclesmin. 100 | Tightening torque |
| Tightening torque | 0.6 Nm |
| Loosening protection | integrated |
| Tool installation | straight knurling and hexagon nut SW = 14 mm |
| Mating cycles | min. 100 |
| Degree of protection | IP66 / IP68 / IP69 |
| Cable | according to IEC/EN 60228 (DIN VDE 0295) class 6 |
| Sheath diameter4.8 mmBending radius> 15 x cable diameter, movable installation > 10 x cable diameter, fixed installationSheath colorblue (similar to RAL 5015)Number of cores2Core cross section0.34 mm2Cores colorCore 1: brown Core 2: blueCore construction42 x 0.1 mm ∅LengthL2 mCable codeLi FY 11Y 2 x 0.34 | Sheath diameter |
| Sheath diameter | 4.8 mm |
| Bending radius | > 15 x cable diameter, movable installation > 10 x cable diameter, fixed installation |
| Sheath color | blue (similar to RAL 5015) |
| Number of cores | 2 |
| Core cross section | 0.34 mm2 |
| Cores color | Core 1: brown Core 2: blue |
| Core construction | 42 x 0.1 mm ∅ |
| Length | 2 m L |
| Cable code | Li FY 11Y 2 x 0.34 |
Material
| Lead-free | yes |
| Plug connector | |
| Screw connectionZinc diecast, nickel-platedBodyTPU, blackSealFKMContact surfacegold plated (Au)FlammabilityV-2 | Screw connection |
| Screw connection | Zinc diecast, nickel-plated |
| Body | TPU, black |
| Seal | FKM |
| Contact surface | gold plated (Au) |
| Flammability | V-2 |
| Cable | |
| SheathingPUR based on polyetherCoresbare copper (Cu)Core insulationPVCFlammabilityHB | Sheathing |
| Sheathing | PUR based on polyether |
| Cores | bare copper (Cu) |
| Core insulation | PVC |
| Flammability | HB |
Data for application in connection with hazardous areas
| EU-type examination certificate | TÜV 24 ATEX 9153X |
| Marking II 1G Ex ia IIC T6 Ga Ta = -25 °C ... +80 °C [exsign] II 1D Ex ia IIIC T200 85°C Da Ta = -25 °C ... +80 °CVoltageUimax. 30 VCurrentIimax. 1 APowerPifor II and IIIB gas groups: 1 W for IIIC gas group (depending on Tamb):40°C / 750 mW, 70 °C / 650 mW, 90 °C / 550 mWAmbient temperatureTamb-25 ... 80 °C (-13 ... 176 °F) | Marking |
| Marking | II 1G Ex ia IIC T6 Ga Ta = -25 °C ... +80 °C [exsign] II 1D Ex ia IIIC T200 85°C Da Ta = -25 °C ... +80 °C |
| Voltage | max. 30 V Ui |
| Current | max. 1 A Ii |
| Power | for II and IIIB gas groups: 1 W for IIIC gas group (depending on Tamb):40°C / 750 mW, 70 °C / 650 mW, 90 °C / 550 mW Pi |
| Ambient temperature | -25 ... 80 °C (-13 ... 176 °F) Tamb |
International approvals
| IECEx approval | IECEx TUR 24.0043X |
General information
| Cable marking sleeve | 1x PUR transparent , fixed to cable |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs V1-W-N-BU10M-PUR-N1-V1-G
Available on requestPepperl Fuchs V1-W-N-BU15M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU20M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU25M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU30M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU40M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU45M-PUR-N1
Available on requestPepperl Fuchs V1-W-N-BU5M-PUR-N1