Pepperl Fuchs SCP-LBF-IA1.36.IE*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Surge Protection |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SCP-LBF-IA1.36.IE* be shipped?
SCP-LBF-IA1.36.IE* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SCP-LBF-IA1.36.IE* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SCP-LBF-IA1.36.IE* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SCP-LBF-IA1.36.IE*, subject to availability and destination.
Surge Protector. Surge protector, pluggable module for spur installation on segment protector, Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 1. Self current consumption: max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0). LED ERR: green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1). Rated voltage: 36 V. Rated current: 250 mA. Voltage protection level: . Line/Linemax. 50 V category B2 10/700 µsec , 25 A max. 53 V category C1 8/20 µsec , 150 A max. 55 V category C2 8/20 µsec , 150 A max. 46 V category C3 1 kV/µsec , 10 A Line/Earthmax. 980 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 50 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1200 V category C3 1 kV/µsec , 50 A per linemax. 980 V category D1 10/350 µsec , 500 A per lineScreen/Shield indirectly grounded (via GDT)max. 500 V category B2 10/700 µsec , 100 A max. 600 V category C1 8/20 µsec , 500 A max. 700 V category C2 8/20 µsec , 10 kA max. 550 V category C3 1 kV/µsec , 100 A max. 570 V category D1 10/350 µsec , 1 kA: . Line/Line: max. 50 V category B2 10/700 µsec , 25 A max. 53 V category C1 8/20 µsec , 150 A max. 55 V category C2 8/20 µsec , 150 A max. 46 V category C3 1 kV/µsec , 10 A. Line/Earth: max. 980 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 50 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1200 V category C3 1 kV/µsec , 50 A per linemax. 980 V category D1 10/350 µsec , 500 A per line. Screen/Shield indirectly grounded (via GDT): max. 500 V category B2 10/700 µsec , 100 A max. 600 V category C1 8/20 µsec , 500 A max. 700 V category C2 8/20 µsec , 10 kA max. 550 V category C3 1 kV/µsec , 100 A max. 570 V category D1 10/350 µsec , 1 kA. Reaction time: . Line/Linemax. 1 nsLine/Earthmax. 100 nsScreen/Shield-Earthmax. 100 ns: . Line/Line: max. 1 ns. Line/Earth: max. 100 ns. Screen/Shield-Earth: max. 100 ns. Overstressed fault mode: according IEC 61643-21 line inoperable mode 2. Impulse durability: . Per line5 kA category C2 8/20 µsecScreen/Shield indirectly grounded (via GDT)1 kA category D1 10/350 µsec 10 kA category C2 8/20 µsec: . Per line: 5 kA category C2 8/20 µsec. Screen/Shield indirectly grounded (via GDT): 1 kA category D1 10/350 µsec 10 kA category C2 8/20 µsec. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NAMUR NE 21. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: IEC 60721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Surge protection: IEC 61643-21. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: screw terminals. Core cross section: flexible wire 2.5 mm2 solid wire max. 4 mm2. Housing material: Polyamide PA 6.6. Degree of protection: IP20. Mass: 45 g. Grounding: M4 screw and external grounding rail. EU-type examination certificate: SIRA 12 ATEX 2128X. Marking II 1G Ex ia IIC T4VoltageUi24 VCurrentIi500 mAInternal capacitanceCi2 nFInternal inductanceLi 0.1 µH: . Marking: II 1G Ex ia IIC T4. Voltage: 24 V. Current: 500 mA. Internal capacitance: 2 nF. Internal inductance: 0.1 µH. Certificate: SIRA 12 ATEX 4176X. Marking II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4VoltageUi33 VCurrentIi600 mAInternal capacitanceCi2 nF: . Marking: II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4. Voltage: 33 V. Current: 600 mA. Internal capacitance: 2 nF. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. Supplementary information: FISCO field device. CSA approval: CoC 2595441. Control drawing116-0365Approved forClass I, Division 1, Groups A, B, C, D T4Class I, Zone 0, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4: . Control drawing: 116-0365. Approved for: Class I, Division 1, Groups A, B, C, D T4Class I, Zone 0, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4. IECEx approval: . IECEx certificateIECEx SIR 12.0051XIECEx markingEx ia IIC T4: . IECEx certificate: IECEx SIR 12.0051X. IECEx marking: Ex ia IIC T4. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Cabinet installation |
| Installation in hazardous area | Zone 1 / Div. 1 |
Fieldbus connection
| Self current consumption | max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0) |
Indicators/operating means
| LED ERR | green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1) |
Electrical specifications
| Rated voltage | 36 V Ur |
| Rated current | 250 mA Ir |
| Voltage protection level | Up |
| Line/Linemax. 50 V category B2 10/700 µsec , 25 A max. 53 V category C1 8/20 µsec , 150 A max. 55 V category C2 8/20 µsec , 150 A max. 46 V category C3 1 kV/µsec , 10 A Line/Earthmax. 980 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 50 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1200 V category C3 1 kV/µsec , 50 A per linemax. 980 V category D1 10/350 µsec , 500 A per lineScreen/Shield indirectly grounded (via GDT)max. 500 V category B2 10/700 µsec , 100 A max. 600 V category C1 8/20 µsec , 500 A max. 700 V category C2 8/20 µsec , 10 kA max. 550 V category C3 1 kV/µsec , 100 A max. 570 V category D1 10/350 µsec , 1 kA | Line/Line |
| Line/Line | max. 50 V category B2 10/700 µsec , 25 A max. 53 V category C1 8/20 µsec , 150 A max. 55 V category C2 8/20 µsec , 150 A max. 46 V category C3 1 kV/µsec , 10 A |
| Line/Earth | max. 980 V category B2 10/700 µsec , 50 A per linemax. 800 V category C1 8/20 µsec , 50 A per linemax. 1450 V category C2 8/20 µsec , 5 kA per linemax. 1200 V category C3 1 kV/µsec , 50 A per linemax. 980 V category D1 10/350 µsec , 500 A per line |
| Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700 µsec , 100 A max. 600 V category C1 8/20 µsec , 500 A max. 700 V category C2 8/20 µsec , 10 kA max. 550 V category C3 1 kV/µsec , 100 A max. 570 V category D1 10/350 µsec , 1 kA |
| Reaction time | tA |
| Line/Linemax. 1 nsLine/Earthmax. 100 nsScreen/Shield-Earthmax. 100 ns | Line/Line |
| Line/Line | max. 1 ns |
| Line/Earth | max. 100 ns |
| Screen/Shield-Earth | max. 100 ns |
| Overstressed fault mode | according IEC 61643-21 line inoperable mode 2 |
| Impulse durability | |
| Per line5 kA category C2 8/20 µsecScreen/Shield indirectly grounded (via GDT)1 kA category D1 10/350 µsec 10 kA category C2 8/20 µsec | Per line |
| Per line | 5 kA category C2 8/20 µsec |
| Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350 µsec 10 kA category C2 8/20 µsec |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NAMUR NE 21 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Climatic conditions | IEC 60721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Surge protection | IEC 61643-21 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | ≤ 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Connection type | screw terminals |
| Core cross section | flexible wire 2.5 mm2 solid wire max. 4 mm2 |
| Housing material | Polyamide PA 6.6 |
| Degree of protection | IP20 |
| Mass | 45 g |
| Grounding | M4 screw and external grounding rail |
Data for application in connection with hazardous areas
| EU-type examination certificate | SIRA 12 ATEX 2128X |
| Marking II 1G Ex ia IIC T4VoltageUi24 VCurrentIi500 mAInternal capacitanceCi2 nFInternal inductanceLi 0.1 µH | Marking |
| Marking | II 1G Ex ia IIC T4 |
| Voltage | 24 V Ui |
| Current | 500 mA Ii |
| Internal capacitance | 2 nF Ci |
| Internal inductance | 0.1 µH Li |
| Certificate | SIRA 12 ATEX 4176X |
| Marking II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4VoltageUi33 VCurrentIi600 mAInternal capacitanceCi2 nF | Marking |
| Marking | II 3G Ex nAc IIC T4 , [exsign] II 3G Ex ic IIC T4 |
| Voltage | 33 V Ui |
| Current | 600 mA Ii |
| Internal capacitance | 2 nF Ci |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
| Supplementary information | FISCO field device |
International approvals
| CSA approval | CoC 2595441 |
| Control drawing116-0365Approved forClass I, Division 1, Groups A, B, C, D T4Class I, Zone 0, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4 | Control drawing |
| Control drawing | 116-0365 |
| Approved for | Class I, Division 1, Groups A, B, C, D T4Class I, Zone 0, Ex ia IIC T4Class I, Zone 2, Ex ic IIC T4Class I, Zone 0, AEx ia IIC T4Class I, Zone 2, AEx ic IIC T4Class I, Division 2, Groups A, B, C, D T4Class I, Zone 2, Ex nL IIC T4Class I, Zone 2, Ex na IIC T4Class I, Zone 2, AEx nAc IIC T4 |
| IECEx approval | |
| IECEx certificateIECEx SIR 12.0051XIECEx markingEx ia IIC T4 | IECEx certificate |
| IECEx certificate | IECEx SIR 12.0051X |
| IECEx marking | Ex ia IIC T4 |
General information
| Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |