Pepperl Fuchs S1SD-2PF
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | SC-System (DIN Rail Mounting, Compact Design) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can S1SD-2PF be shipped?
S1SD-2PF is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up S1SD-2PF in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for S1SD-2PF and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for S1SD-2PF, subject to availability and destination.
Power Feed Module. Interface for Power Bus, Supply current 3 A, LED status indication, Connection via screw terminals. Connection: Power Bus or terminals 1-, 2+; 7+, 8-. Rated voltage: 16.8 ... 31.2 V DC. Fusing: 4 AT with back-up fuse. Power dissipation: 0.8 W. Connection: Power Bus. Output current: max. 3 A. Output voltage: 24 V DC. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Degree of protection: IEC 60529:2001. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20. Connection: screw terminals. Core cross section: 0.5 ... 2.5 mm2 (20 ... 14 AWG). Mass: approx. 70 g. Dimensions: 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1. Height97 mmWidth6.2 mmDepth107 mm: . Height: 97 mm. Width: 6.2 mm. Depth: 107 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Certificate: DEMKO 16 ATEX 1750X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-15:2010. UL approval: E106378. IECEx approval: . IECEx certificateIECEx UL 16.0116XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx UL 16.0116X. IECEx marking: Ex nA IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | Power Bus or terminals 1-, 2+; 7+, 8- |
| Rated voltage | 16.8 ... 31.2 V DC Ur |
| Fusing | 4 AT with back-up fuse |
| Power dissipation | 0.8 W |
Output
| Connection | Power Bus |
| Output current | max. 3 A |
| Output voltage | 24 V DC |
Indicators/settings
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Core cross section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) |
| Mass | approx. 70 g |
| Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1 |
| Height97 mmWidth6.2 mmDepth107 mm | Height |
| Height | 97 mm |
| Width | 6.2 mm |
| Depth | 107 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| Certificate | DEMKO 16 ATEX 1750X |
| Marking II 3G Ex nA IIC T4 Gc | Marking |
| Marking | II 3G Ex nA IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
International approvals
| UL approval | E106378 |
| IECEx approval | |
| IECEx certificateIECEx UL 16.0116XIECEx markingEx nA IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx UL 16.0116X |
| IECEx marking | Ex nA IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G