Available on request

Pepperl Fuchs RD0-TI-Ex8.FF.*

MPN: RD0-TI-Ex8.FF.* · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryProcess Interfaces for FOUNDATION Fieldbus H1
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can RD0-TI-Ex8.FF.* be shipped?

RD0-TI-Ex8.FF.* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up RD0-TI-Ex8.FF.* in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for RD0-TI-Ex8.FF.* and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for RD0-TI-Ex8.FF.*, subject to availability and destination.

Temperature Multi-Input. Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 1. Fieldbus type: FOUNDATION Fieldbus. Physical layer profile: profile type 511 (FISCO), profile type 111 (Entity). ITK version: 6.2.0 (DEV_REV 02). Implementation: resource block 1x RSfunction block 8x AI, 1x MAItransducer block 8x sensor TB, 1x concentrator TB. Execution time: AI, MAI 40 ms max.. Macro cycle: typical for one device 8xAI or 1xMAI max. 500 ms. Firmware update: via separate plug connection. FDE (Fault Disconnect Equipment): 6.7 mA. Polarity: not polarity sensitive. Rated voltage: 9 ... 32 V. Rated current: max. 23 mA. LED PWR: green: on, bus voltage existent. LED COM ERR: red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error. LED CHANNEL ERROR: red: 2 Hz flashing: lead breakage, overrange; off: no error. Number: 8. Sensor types: see table 1. Grounding: grounding of thermoelements possible. Error detection: lead breakage, wiring error, hardware device error. Common mode voltage: Input to Input 600 Vpeak. Deviation: . Cold junction compensation± 0.5 °C (32.9 °F)Resolution/accuracysee table 2Influence of ambient temperaturesee table 3LinearizationT/C input 0.1°C RTD input 0.03°C: . Cold junction compensation: ± 0.5 °C (32.9 °F). Resolution/accuracy: see table 2. Influence of ambient temperature: see table 3. Linearization: T/C input 0.1°C RTD input 0.03°C. Internal measurement cycle: for all sensor types max. 1 s. Fieldbus/inputs: safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Galvanic isolation: EN 60079-11. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F) hazardous area -40 ... 85 °C (-40 ... 185 °F) safe area. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g , 11 ms. Vibration resistance: 5 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: plug-in terminals , spring terminal and screw terminal. Core cross section: . Busup to 2.5 mm2Inputsup to 2.5 mm2: . Bus: up to 2.5 mm2. Inputs: up to 2.5 mm2. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 360 g. Mounting: DIN rail mounting. EU-type examination certificate: PTB 03 ATEX 2237. Marking II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc: . Marking: II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc. Bus: FISCO see EC-Type Examination Certificate. Inputs: see EC-Type Examination Certificate. Certificate: PTB 03 ATEX 2238 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Galvanic isolation: . Bussee Statement of ConformityInputsee EC-Type Examination Certificate: . Bus: see Statement of Conformity. Input: see EC-Type Examination Certificate. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . FM certificateFM18US0054X , FM18CA0027XControl drawing16-473FM-12A: . FM certificate: FM18US0054X , FM18CA0027X. Control drawing: 16-473FM-12A. IECEx approval: . IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002XIECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc: . IECEx certificate: IECEx PTB 05.0001 IECEx PTB 05.0002X. IECEx marking: Ex ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Design / MountingCabinet installation
Installation in hazardous areaZone 1 / Div. 1

Fieldbus connection

Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
ITK version6.2.0 (DEV_REV 02)
Implementationresource block 1x RSfunction block 8x AI, 1x MAItransducer block 8x sensor TB, 1x concentrator TB
Execution timeAI, MAI 40 ms max.
Macro cycletypical for one device 8xAI or 1xMAI max. 500 ms
Firmware updatevia separate plug connection
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V UN
Rated currentmax. 23 mA IN

Indicators/operating means

LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange; off: no error

Input

Number8
Sensor typessee table 1
Groundinggrounding of thermoelements possible
Error detectionlead breakage, wiring error, hardware device error
Common mode voltageInput to Input 600 Vpeak

Transfer characteristics

Deviation
Cold junction compensation± 0.5 °C (32.9 °F)Resolution/accuracysee table 2Influence of ambient temperaturesee table 3LinearizationT/C input 0.1°C RTD input 0.03°C Cold junction compensation
Cold junction compensation± 0.5 °C (32.9 °F)
Resolution/accuracysee table 2
Influence of ambient temperaturesee table 3
LinearizationT/C input 0.1°C RTD input 0.03°C
Internal measurement cyclefor all sensor types max. 1 s

Galvanic isolation

Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area -40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Connection typeplug-in terminals , spring terminal and screw terminal
Core cross section
Busup to 2.5 mm2Inputsup to 2.5 mm2 Bus
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Mass360 g
MountingDIN rail mounting

Data for application in connection with hazardous areas

EU-type examination certificatePTB 03 ATEX 2237
Marking II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc Marking
MarkingII 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
Marking II 3 G Ex nA IIC T4 Gc Marking
MarkingII 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of ConformityInputsee EC-Type Examination Certificate Bus
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

FM approval
FM certificateFM18US0054X , FM18CA0027XControl drawing16-473FM-12A FM certificate
FM certificateFM18US0054X , FM18CA0027X
Control drawing16-473FM-12A
IECEx approval
IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002XIECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc IECEx certificate
IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002X
IECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote