Pepperl Fuchs R4D0-FB-IA*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | FieldBarriers |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can R4D0-FB-IA* be shipped?
R4D0-FB-IA* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up R4D0-FB-IA* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for R4D0-FB-IA* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for R4D0-FB-IA*, subject to availability and destination.
Fieldbus Barrier. Fieldbus barrier, module for DIN rail mounting, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Division 2 - high-power trunk<BR>Division 1 - high-power trunk. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 2. Power dissipation: see table 1. Main cable (Trunk): . Rated voltage16 ... 32 V DC ,min. 15 V in case of brown outRated currenttrunk IN to trunk OUT max. 2 A see table 1 Cable shield grounding optionCapacitive via 5.7 nF DirectVoltage droptrunk IN to trunk OUT 100 mV max.Number of couplersmax. 3 per segmentReverse polarity protectionBuilt-In: . Rated voltage: 16 ... 32 V DC ,min. 15 V in case of brown out. Rated current: trunk IN to trunk OUT max. 2 A see table 1. Cable shield grounding option: Capacitive via 5.7 nF Direct. Voltage drop: trunk IN to trunk OUT 100 mV max.. Number of couplers: max. 3 per segment. Reverse polarity protection: Built-In. Outputs: . Number of outputs8, 10 or 12Number of devices per output1Cable length120 mRated voltage10 ... 14 VRated currentmax. 43 mA at one spur ,max. 320 mA total current at all spursShort-circuit current53 mA , 1 mA in fallback stateCable shield grounding optionCapacitive via 4.4 nF: . Number of outputs: 8, 10 or 12. Number of devices per output: 1. Cable length: 120 m. Rated voltage: 10 ... 14 V. Rated current: max. 43 mA at one spur ,max. 320 mA total current at all spurs. Short-circuit current: 53 mA , 1 mA in fallback state. Cable shield grounding option: Capacitive via 4.4 nF. Surge protection: Trunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V. Fault Isolation: Short Circuit Current Limitation at spurs Bounce Protection at spurs Signal inhibit at spurs. Physical Layer Diagnostic: Signal level at spurs Signal jitter at spurs Noise level at spurs. Switch: S1 ON: diagnostic alarms activated S2 ON: diagnostic warnings activated S3-S8: not used. LED PWR: green: Fieldbus voltage > 16 V. LED COM/ERR: yellow flashing: fieldbus communication and physical layer status ,red: Hardware error. LED SPURS: red: 2 Hz flashing in short-circuit condition. Main wire/outputs: isolation is not affected by interference according to EN 60079-11, voltage peak value 375 V. Output/Output: No Isolation. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC/EN 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: IEC 60721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: screw terminal , pluggable or spring terminal , pluggable. Core cross section: see table 2. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 2100 g. Dimensions: see dimensions. Mounting: DIN rail mounting. EU-type examination certificate: BVS 13 ATEX E 121 X. Marking II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Main cable (Trunk): . Maximum safe voltage Um253 V AC: . Maximum safe voltage Um: 253 V AC. Outputs: in accordance to FISCO and Entity. PowerPo1.063 WVoltageUo17.1 VCurrentIo248.55 mAInductanceLogas group IIC 470 µH ,gas group IIB 2 mHCapacitanceCogas group IIC 367 nF ,gas group IIB 2.15 µF: Po. Power: 1.063 W. Voltage: 17.1 V. Current: 248.55 mA. Inductance: gas group IIC 470 µH ,gas group IIB 2 mH. Capacitance: gas group IIC 367 nF ,gas group IIB 2.15 µF. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015. CSA approval: CSA 14.70004139. Control drawing116-0400Approved forClass I, Division 2, Groups A, B, C, D T4Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 GbClass I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 GbAssociated equipment for Class I, Division 1 Groups A, B, C, DAssociated equipment for Class II, Division 1 Groups E, F, GAssociated equipment for Class III, Division 1: . Control drawing: 116-0400. Approved for: Class I, Division 2, Groups A, B, C, D T4Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 GbClass I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 GbAssociated equipment for Class I, Division 1 Groups A, B, C, DAssociated equipment for Class II, Division 1 Groups E, F, GAssociated equipment for Class III, Division 1. IECEx approval: . IECEx certificateIECEx BVS 13.0119XIECEx markingEx eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx BVS 13.0119X. IECEx marking: Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I. FOUNDATION Fieldbus: FF-846. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Cabinet installation |
| Installation in hazardous area | Zone 1 / Div. 2 |
Fieldbus connection
| Power dissipation | see table 1 |
| Main cable (Trunk) | |
| Rated voltage16 ... 32 V DC ,min. 15 V in case of brown outRated currenttrunk IN to trunk OUT max. 2 A see table 1 Cable shield grounding optionCapacitive via 5.7 nF DirectVoltage droptrunk IN to trunk OUT 100 mV max.Number of couplersmax. 3 per segmentReverse polarity protectionBuilt-In | Rated voltage |
| Rated voltage | 16 ... 32 V DC ,min. 15 V in case of brown out |
| Rated current | trunk IN to trunk OUT max. 2 A see table 1 |
| Cable shield grounding option | Capacitive via 5.7 nF Direct |
| Voltage drop | trunk IN to trunk OUT 100 mV max. |
| Number of couplers | max. 3 per segment |
| Reverse polarity protection | Built-In |
| Outputs | |
| Number of outputs8, 10 or 12Number of devices per output1Cable length120 mRated voltage10 ... 14 VRated currentmax. 43 mA at one spur ,max. 320 mA total current at all spursShort-circuit current53 mA , 1 mA in fallback stateCable shield grounding optionCapacitive via 4.4 nF | Number of outputs |
| Number of outputs | 8, 10 or 12 |
| Number of devices per output | 1 |
| Cable length | 120 m |
| Rated voltage | 10 ... 14 V |
| Rated current | max. 43 mA at one spur ,max. 320 mA total current at all spurs |
| Short-circuit current | 53 mA , 1 mA in fallback state |
| Cable shield grounding option | Capacitive via 4.4 nF |
| Surge protection | Trunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V |
Diagnostic and Protection Features
| Fault Isolation | Short Circuit Current Limitation at spurs Bounce Protection at spurs Signal inhibit at spurs |
| Physical Layer Diagnostic | Signal level at spurs Signal jitter at spurs Noise level at spurs |
Indicators/operating means
| Switch | S1 ON: diagnostic alarms activated S2 ON: diagnostic warnings activated S3-S8: not used |
| LED PWR | green: Fieldbus voltage > 16 V |
| LED COM/ERR | yellow flashing: fieldbus communication and physical layer status ,red: Hardware error |
| LED SPURS | red: 2 Hz flashing in short-circuit condition |
Galvanic isolation
| Main wire/outputs | isolation is not affected by interference according to EN 60079-11, voltage peak value 375 V |
| Output/Output | No Isolation |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC/EN 60529 |
| Fieldbus standard | IEC 61158-2 |
| Climatic conditions | IEC 60721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Connection type | screw terminal , pluggable or spring terminal , pluggable |
| Core cross section | see table 2 |
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | 2100 g |
| Dimensions | see dimensions |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| EU-type examination certificate | BVS 13 ATEX E 121 X |
| Marking II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I | Marking |
| Marking | II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Main cable (Trunk) | |
| Maximum safe voltage Um253 V AC | Maximum safe voltage Um |
| Maximum safe voltage Um | 253 V AC |
| Outputs | in accordance to FISCO and Entity |
| PowerPo1.063 WVoltageUo17.1 VCurrentIo248.55 mAInductanceLogas group IIC 470 µH ,gas group IIB 2 mHCapacitanceCogas group IIC 367 nF ,gas group IIB 2.15 µF | Po Power |
| Power | 1.063 W Po |
| Voltage | 17.1 V Uo |
| Current | 248.55 mA Io |
| Inductance | gas group IIC 470 µH ,gas group IIB 2 mH Lo |
| Capacitance | gas group IIC 367 nF ,gas group IIB 2.15 µF Co |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015 |
International approvals
| CSA approval | CSA 14.70004139 |
| Control drawing116-0400Approved forClass I, Division 2, Groups A, B, C, D T4Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 GbClass I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 GbAssociated equipment for Class I, Division 1 Groups A, B, C, DAssociated equipment for Class II, Division 1 Groups E, F, GAssociated equipment for Class III, Division 1 | Control drawing |
| Control drawing | 116-0400 |
| Approved for | Class I, Division 2, Groups A, B, C, D T4Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 GbClass I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 GbAssociated equipment for Class I, Division 1 Groups A, B, C, DAssociated equipment for Class II, Division 1 Groups E, F, GAssociated equipment for Class III, Division 1 |
| IECEx approval | |
| IECEx certificateIECEx BVS 13.0119XIECEx markingEx eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I | IECEx certificate |
| IECEx certificate | IECEx BVS 13.0119X |
| IECEx marking | Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I |
Certificates and approvals
| FOUNDATION Fieldbus | FF-846 |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G