Pepperl Fuchs PS1000-A9-24.40
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Industrial Power Supplies |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PS1000-A9-24.40 be shipped?
PS1000-A9-24.40 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PS1000-A9-24.40 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PS1000-A9-24.40 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PS1000-A9-24.40, subject to availability and destination.
Power Supply. 380 V AC to 480 V AC wide-range inputs, Output 24 V DC, 40 A, 960 W, 3-phase, Housing width 110 mm, Efficiency up to 95.3 %, Minimal inrush current surge, Shutdown input, Remote control for ON/OFF, DC OK relay contact, Current sharing for parallel use, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC <BR>factory setting: 24.1 V. Efficiency: 95.3 % at 3 x 400 V AC 95.2 % at 3 x 480 V AC. Power dissipation: 47.3 W at 3 x 400 V AC 48.4 W at 3 x 480 V AC. Voltage range: 3x 380 ... 480 V AC (-15 %/+20 %), 50 ... 60 Hz (±6 %). Current: 1.65 A at 3 x 400 V AC 1.35 A at 3 x 480 V AC for lower output currents see technical information. Inrush current: 4.5 A peak at 3 x 400 V AC, temperature-independent 4.5 A peak at 3 x 480 V AC , temperature-independent. Capacity factor: 0.88 at 3 x 400 V AC 0.9 at 3 x 480 V AC. Remote control: terminals 15, 16 remote control for ON/OFF and shutdown input. Rated voltage: 24 V DC. Voltage range: 24 ... 28 V DC factory setting: 24.1 V. Rated current: 40 A. Current: continuous: 40 ... 34.3 A short-term up to 4 s: 60 ... 51.5 A linear power derating see technical information. Power: 960 W. Ripple: max. 100 mV pp. Hold-up time: 25 ms at 3 x 400 V AC 25 ms at 3 x 480 V AC. Overload behavior: constant current mode. Short-circuit current: typ. 46 A continuous, load impedance < 10 mΩ. Voltage limitation: typ. 30.5 V DC max. 32 V DC. Connection: terminals 13, 14. Output type: relay contact DC OK - contact is closed if the output voltage is > 90 % of the adjusted output voltage. Contact loading: max. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load min. 1 mA at 5 V DC. Input/Output: SELV/PELV. Display elements: LED green: status DC OK - LED lights up if the output voltage is > 90 % of the adjusted output voltage LED red: overload - LED lights up if the output voltage is < 90 % of the adjusted output voltage or in case of short circuit - flashes if the shutdown has been activated or if the device has shut down due to overtemperature. Control elements: potentiometer , plug-in jumper. Configuration: setting of the output voltage via potentiometer setting of the operating mode- plug-in jumper plugged in: "parallel use" operating mode- plug-in jumper not plugged in: "single use" operating mode setting of the shutdown input:- plug-in jumper plugged in: device switches off. Electromagnetic compatibility: . Directive 2014/30/EUIEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 , IEC/EN 61000-3-3: . Directive 2014/30/EU: IEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 , IEC/EN 61000-3-3. Low voltage: . Directive 2014/35/EUEN 61010-1: . Directive 2014/35/EU: EN 61010-1. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000:2019: . Directive 2011/65/EU (RoHS): IEC/EN 63000:2019. Degree of protection: EN 60529. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F) , see technical information. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 5 ... 95 %, noncondensing. Shock resistance: 15 g , 6 ms or 10 g , 11 ms. Vibration resistance: 2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 1 g. Housing material: aluminum alloy , galvanized steel. Degree of protection: IP20. Connection: . Inputscrew terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 1 NmOutputscrew terminals conductor cross section: max. 16 mm2 (AWG 22-8) cable diameter: max. 5.2 mm, wire end ferrules included stripped insulation length: 12 mm tightening torque: max. 2.3 NmRelay contact outputspring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mmRemote control/shutdown inputspring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm: . Input: screw terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 1 Nm. Output: screw terminals conductor cross section: max. 16 mm2 (AWG 22-8) cable diameter: max. 5.2 mm, wire end ferrules included stripped insulation length: 12 mm tightening torque: max. 2.3 Nm. Relay contact output: spring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm. Remote control/shutdown input: spring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm. Mass: approx. 1500 g. Dimensions: 110 x 124 x 127 mm (W x H x D) , without DIN mounting rail. Height124 mmWidth110 mmDepth127 mm: . Height: 124 mm. Width: 110 mm. Depth: 127 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. UL approval: E223176. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Electrical specifications
| Efficiency | 95.3 % at 3 x 400 V AC 95.2 % at 3 x 480 V AC |
| Power dissipation | 47.3 W at 3 x 400 V AC 48.4 W at 3 x 480 V AC |
Input
| Voltage range | 3x 380 ... 480 V AC (-15 %/+20 %), 50 ... 60 Hz (±6 %) |
| Current | 1.65 A at 3 x 400 V AC 1.35 A at 3 x 480 V AC for lower output currents see technical information |
| Inrush current | 4.5 A peak at 3 x 400 V AC, temperature-independent 4.5 A peak at 3 x 480 V AC , temperature-independent |
| Capacity factor | 0.88 at 3 x 400 V AC 0.9 at 3 x 480 V AC |
| Remote control | terminals 15, 16 remote control for ON/OFF and shutdown input |
Output
| Rated voltage | 24 V DC Ur |
| Voltage range | 24 ... 28 V DC factory setting: 24.1 V |
| Rated current | 40 A Ir |
| Current | continuous: 40 ... 34.3 A short-term up to 4 s: 60 ... 51.5 A linear power derating see technical information |
| Power | 960 W |
| Ripple | max. 100 mV pp |
| Hold-up time | 25 ms at 3 x 400 V AC 25 ms at 3 x 480 V AC |
| Overload behavior | constant current mode |
| Short-circuit current | typ. 46 A continuous, load impedance < 10 mΩ |
| Voltage limitation | typ. 30.5 V DC max. 32 V DC |
Fault indication output
| Connection | terminals 13, 14 |
| Output type | relay contact DC OK - contact is closed if the output voltage is > 90 % of the adjusted output voltage |
| Contact loading | max. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load min. 1 mA at 5 V DC |
Galvanic isolation
| Input/Output | SELV/PELV |
Indicators/settings
| Display elements | LED green: status DC OK - LED lights up if the output voltage is > 90 % of the adjusted output voltage LED red: overload - LED lights up if the output voltage is < 90 % of the adjusted output voltage or in case of short circuit - flashes if the shutdown has been activated or if the device has shut down due to overtemperature |
| Control elements | potentiometer , plug-in jumper |
| Configuration | setting of the output voltage via potentiometer setting of the operating mode- plug-in jumper plugged in: "parallel use" operating mode- plug-in jumper not plugged in: "single use" operating mode setting of the shutdown input:- plug-in jumper plugged in: device switches off |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUIEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 , IEC/EN 61000-3-3 | Directive 2014/30/EU |
| Directive 2014/30/EU | IEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 , IEC/EN 61000-3-3 |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1 |
| RoHS | |
| Directive 2011/65/EU (RoHS)IEC/EN 63000:2019 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | IEC/EN 63000:2019 |
Conformity
| Degree of protection | EN 60529 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) , see technical information |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 5 ... 95 %, noncondensing |
| Shock resistance | 15 g , 6 ms or 10 g , 11 ms |
| Vibration resistance | 2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 1 g |
Mechanical specifications
| Housing material | aluminum alloy , galvanized steel |
| Degree of protection | IP20 |
| Connection | |
| Inputscrew terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 1 NmOutputscrew terminals conductor cross section: max. 16 mm2 (AWG 22-8) cable diameter: max. 5.2 mm, wire end ferrules included stripped insulation length: 12 mm tightening torque: max. 2.3 NmRelay contact outputspring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mmRemote control/shutdown inputspring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm | Input |
| Input | screw terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 1 Nm |
| Output | screw terminals conductor cross section: max. 16 mm2 (AWG 22-8) cable diameter: max. 5.2 mm, wire end ferrules included stripped insulation length: 12 mm tightening torque: max. 2.3 Nm |
| Relay contact output | spring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm |
| Remote control/shutdown input | spring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm |
| Mass | approx. 1500 g |
| Dimensions | 110 x 124 x 127 mm (W x H x D) , without DIN mounting rail |
| Height124 mmWidth110 mmDepth127 mm | Height |
| Height | 124 mm |
| Width | 110 mm |
| Depth | 127 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
International approvals
| UL approval | E223176 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G