Quick facts
| Availability | Confirmed on request |
| Category | Hydrostatic Pressure Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PPC-M51 be shipped?
PPC-M51 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PPC-M51 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PPC-M51 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PPC-M51, subject to availability and destination.
Pressure Transmitter. Device for absolute pressure and gauge pressure measurement in gases, steams or liquids, Large selection of process connections: universal use, Temperature range up to 130 °C (266 °F), Pressure range up to 40 bar (600 psi), Easy commissioning without the need for an operating tool, Configurable by PACTware. Construction type: sensor: ceramic sensorceramic diaphragm. Series: PPC-M51. Rated voltage: versions for safe area:11.5 ... 45 V DC, 2-wire11.5 ... 35 V DC, HART, 2-wire9 ... 32 V DC, PROFIBUS PAversion for hazardous area see safety information (SI). Measured variable: absolute or relative pressure. Measuring range: 0.1 ... 40 bar max. turn down: 100:1. Output signal: 4 ... 20 mA , analog , 2-wire4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wiredigital communication signal PROFIBUS PA (Profile 3.02). Communication: 4 ... 20 mA HART (standard)PROFIBUS PA (option). Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006: . Directive 2014/30/EU: EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006. Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Degree of protection: IEC 60529:2001. Accuracy: reference accuracy: ±0.15 % (standard), ±0.075 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span.. Long-term drift: up to ±0.1 % of upper range limit (URL)/year. Process conditions: . Process temperature-40 ... 100 °C (-40 ... 212 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h): . Process temperature: -40 ... 100 °C (-40 ... 212 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h). Ambient temperature: -40 ... 85 °C (-40 ... 185 °F) with display : -20 ... 70 °C (-4 ... 158 °F). Degree of protection: IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable). Connection: gland M20thread M20, G1/2, NPT1/2device plug M12HAN7D Harting connector, angledvalve connector acc. ISO 4400, cable 5 m. Material: materials in contact with process : Al2O3 ceramic (ultrapure 99.9 %) housing:- die-cast aluminum with protective powder-coating on polyester base, housing F31- stainless steel AISI 316L (1.4404), housing F15measuring cell seal: Viton, EPDM, NBR, Kalrez. Process connection: threads ISO 228: G1/2, G1, G1-1/2, G2threads ANSI: NPT1/2, NPT1, NPT1-1/2, NPT2hygienic process connections: Clamp, Varivent, DRD, DIN 11851, DIN 11864, NEUMO, APV, uni adapterflanges: EN 1092-1: DN 25 ... DN 80, ANSI 16.5: 1 ... 4 inch, JIS B2220. EU-type examination certificate: see instruction manuals (SI). Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009. FM approval: see instruction manuals (SI). CSA approval: see instruction manuals (SI). IECEx approval: see instruction manuals (SI). Drinking water approval: NSF61 approval. Supplementary documentation: technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) control drawings (ZD) approval (ZE). Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.. Designation: see technical information (TI)
Specifications
General specifications
| Construction type | sensor: ceramic sensorceramic diaphragm |
| Series | PPC-M51 |
Supply
| Rated voltage | versions for safe area:11.5 ... 45 V DC, 2-wire11.5 ... 35 V DC, HART, 2-wire9 ... 32 V DC, PROFIBUS PAversion for hazardous area see safety information (SI) Ur |
Input
| Measured variable | absolute or relative pressure |
| Measuring range | 0.1 ... 40 bar max. turn down: 100:1 |
Output
| Output signal | 4 ... 20 mA , analog , 2-wire4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wiredigital communication signal PROFIBUS PA (Profile 3.02) |
| Communication | 4 ... 20 mA HART (standard)PROFIBUS PA (option) |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006 |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1:2010 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Degree of protection | IEC 60529:2001 |
Measurement accuracy
| Accuracy | reference accuracy: ±0.15 % (standard), ±0.075 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span. |
| Long-term drift | up to ±0.1 % of upper range limit (URL)/year |
Operating conditions
| Process conditions | |
| Process temperature-40 ... 100 °C (-40 ... 212 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h) | Process temperature |
| Process temperature | -40 ... 100 °C (-40 ... 212 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h) |
Ambient conditions
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) with display : -20 ... 70 °C (-4 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable) |
| Connection | gland M20thread M20, G1/2, NPT1/2device plug M12HAN7D Harting connector, angledvalve connector acc. ISO 4400, cable 5 m |
| Material | materials in contact with process : Al2O3 ceramic (ultrapure 99.9 %) housing:- die-cast aluminum with protective powder-coating on polyester base, housing F31- stainless steel AISI 316L (1.4404), housing F15measuring cell seal: Viton, EPDM, NBR, Kalrez |
| Process connection | threads ISO 228: G1/2, G1, G1-1/2, G2threads ANSI: NPT1/2, NPT1, NPT1-1/2, NPT2hygienic process connections: Clamp, Varivent, DRD, DIN 11851, DIN 11864, NEUMO, APV, uni adapterflanges: EN 1092-1: DN 25 ... DN 80, ANSI 16.5: 1 ... 4 inch, JIS B2220 |
Data for application in connection with hazardous areas
| EU-type examination certificate | see instruction manuals (SI) |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 |
International approvals
| FM approval | see instruction manuals (SI) |
| CSA approval | see instruction manuals (SI) |
| IECEx approval | see instruction manuals (SI) |
Certificates and approvals
| Drinking water approval | NSF61 approval |
General information
| Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) control drawings (ZD) approval (ZE) |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Accessories
| Designation | see technical information (TI) |
More Pepperl Fuchs parts