Pepperl Fuchs OBT100-R101-2EP-IO-1T-L – Triangulation sensor (BGE). Laser diffuse mode sensor with…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Diffuse Mode Sensors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can OBT100-R101-2EP-IO-1T-L be shipped?
OBT100-R101-2EP-IO-1T-L is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up OBT100-R101-2EP-IO-1T-L in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for OBT100-R101-2EP-IO-1T-L and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for OBT100-R101-2EP-IO-1T-L, subject to availability and destination.
Triangulation sensor (BGE). Laser diffuse mode sensor with background evaluation, Miniature design with versatile mounting options, Secure and gapless detection, even near the surface through background evaluation, DuraBeam Laser Sensors - durable and employable like an LED, Extended temperature range
-40 °C ... 60 °C, High degree of protection IP69K. Detection range: 7 ... 100 mm. Detection range min.: 7 ... 25 mm. Detection range max.: 7 ... 100 mm. Adjustment range: 25 ... 100 mm. Reference target: standard white, 100 mm x 100 mm. Light source: laser diode. Light type: modulated visible red light. Laser nominal ratings: . NoteLASER LIGHT , DO NOT STARE INTO BEAMLaser class1Wave length680 nmBeam divergence> 5 mrad d63 5 mrad d63 < 1 mm in the range of 150 mm ... 250 mm. Pulse length: 3 µs. Repetition rate: approx. 13 kHz. max. pulse energy: 10.4 nJ. Black-white difference (6 %/90 %): < 5 % at 150 mm. Diameter of the light spot: < 1 mm at a distance of 60 mm. Opening angle: approx. 0.3 °. Ambient light limit: EN 60947-5-2 : 40000 Lux. MTTFd: 560 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Operation indicator: LED green:constantly on - power onflashing (4Hz) - short circuitflashing with short break (1 Hz) - IO-Link mode. Function indicator: LED yellow:constantly on - background detected (object not detected)constantly off - object detected. Control elements: Light-on/dark-on changeover switch. Control elements: Sensing range adjuster. Operating voltage: 10 ... 30 V DC. Ripple: max. 10 %. No-load supply current: < 20 mA at 24 V supply voltage. Protection class: III. Interface type: IO-Link ( via C/Q = BK ). IO-Link revision: 1.1. Device profile: Smart Sensor. Device ID: 0x110703 (1115907). Transfer rate: COM2 (38.4 kBit/s). Min. cycle time: 2.3 ms. Process data width: Process data input 1 BitProcess data output 2 Bit. SIO mode support: yes. Compatible master port type: A. Switching type: The switching type of the sensor is adjustable. The default setting is: C/Q - BK: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link /Q - WH: NPN normally closed / light-on, PNP normally open / dark-on. Signal output: 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected. Switching voltage: max. 30 V DC. Switching current: max. 100 mA , resistive load. Usage category: DC-12 and DC-13. Voltage drop: ≤ 1.5 V DC. Switching frequency: 1650 Hz. Response time: 300 µs. Communication interface: IEC 61131-9. Product standard: EN 60947-5-2. Laser safety: EN 60825-1:2014. UL approval: E87056 , cULus Listed , class 2 power supply , type rating 1. FDA approval: IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) , cable, fixed installation -25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains. Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP67 / IP69 / IP69K. Connection: 2 m fixed cable. Material: . HousingPC (Polycarbonate)Optical facePMMA: . Housing: PC (Polycarbonate). Optical face: PMMA. Mass: approx. 36 g. Dimensions: . Height33.8 mmWidth13.9 mmDepth18.3 mm: . Height: 33.8 mm. Width: 13.9 mm. Depth: 18.3 mm. Cable length: 2 m
Specifications
General specifications
| Detection range | 7 ... 100 mm |
| Detection range min. | 7 ... 25 mm |
| Detection range max. | 7 ... 100 mm |
| Adjustment range | 25 ... 100 mm |
| Reference target | standard white, 100 mm x 100 mm |
| Light source | laser diode |
| Light type | modulated visible red light |
| Laser nominal ratings | |
| NoteLASER LIGHT , DO NOT STARE INTO BEAMLaser class1Wave length680 nmBeam divergence> 5 mrad d63 < 1 mm in the range of 150 mm ... 250 mmPulse length3 µsRepetition rateapprox. 13 kHzmax. pulse energy10.4 nJ | Note |
| Note | LASER LIGHT , DO NOT STARE INTO BEAM |
| Laser class | 1 |
| Wave length | 680 nm |
| Beam divergence | > 5 mrad d63 < 1 mm in the range of 150 mm ... 250 mm |
| Pulse length | 3 µs |
| Repetition rate | approx. 13 kHz |
| max. pulse energy | 10.4 nJ |
| Black-white difference (6 %/90 %) | < 5 % at 150 mm |
| Diameter of the light spot | < 1 mm at a distance of 60 mm |
| Opening angle | approx. 0.3 ° |
| Ambient light limit | EN 60947-5-2 : 40000 Lux |
Functional safety related parameters
| MTTFd | 560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Operation indicator | LED green:constantly on - power onflashing (4Hz) - short circuitflashing with short break (1 Hz) - IO-Link mode |
| Function indicator | LED yellow:constantly on - background detected (object not detected)constantly off - object detected |
| Control elements | Light-on/dark-on changeover switch |
| Control elements | Sensing range adjuster |
Electrical specifications
| Operating voltage | 10 ... 30 V DC UB |
| Ripple | max. 10 % |
| No-load supply current | < 20 mA at 24 V supply voltage I0 |
| Protection class | III |
Interface
| Interface type | IO-Link ( via C/Q = BK ) |
| IO-Link revision | 1.1 |
| Device profile | Smart Sensor |
| Device ID | 0x110703 (1115907) |
| Transfer rate | COM2 (38.4 kBit/s) |
| Min. cycle time | 2.3 ms |
| Process data width | Process data input 1 BitProcess data output 2 Bit |
| SIO mode support | yes |
| Compatible master port type | A |
Output
| Switching type | The switching type of the sensor is adjustable. The default setting is: C/Q - BK: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link /Q - WH: NPN normally closed / light-on, PNP normally open / dark-on |
| Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
| Switching voltage | max. 30 V DC |
| Switching current | max. 100 mA , resistive load |
| Usage category | DC-12 and DC-13 |
| Voltage drop | ≤ 1.5 V DC Ud |
| Switching frequency | 1650 Hz f |
| Response time | 300 µs |
Conformity
| Communication interface | IEC 61131-9 |
| Product standard | EN 60947-5-2 |
| Laser safety | EN 60825-1:2014 |
Approvals and certificates
| UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
| FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , cable, fixed installation -25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP67 / IP69 / IP69K |
| Connection | 2 m fixed cable |
| Material | |
| HousingPC (Polycarbonate)Optical facePMMA | Housing |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
| Mass | approx. 36 g |
| Dimensions | |
| Height33.8 mmWidth13.9 mmDepth18.3 mm | Height |
| Height | 33.8 mm |
| Width | 13.9 mm |
| Depth | 18.3 mm |
| Cable length | 2 m |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs OBT100-R100-EP-IO-V3-1T-L – Triangulation sensor (BGE). Laser diffuse mode sensor with…
Available on requestPepperl Fuchs OBT100-R100-EP-IO-V3-L
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-0,3M-V1-L
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-0,3M-V31-L
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-1T-L-Y0244 – Triangulation sensor (BGE). Laser diffuse mode sensor with…
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-1T-L-Y0245 – Triangulation sensor (BGE). Laser diffuse mode sensor with…
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-L
Available on requestPepperl Fuchs OBT100-R101-2EP-IO-V31-1T-L – Triangulation sensor (BGE). Laser diffuse mode sensor with…