Pepperl Fuchs OBE35M-R202-SK2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Thru-Beam Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can OBE35M-R202-SK2 be shipped?
OBE35M-R202-SK2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up OBE35M-R202-SK2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for OBE35M-R202-SK2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for OBE35M-R202-SK2, subject to availability and destination.
Thru-beam sensor (pair). Version for universal voltages, Medium design with versatile mounting options, Degree of protection IP67, Mounting on full metal sockets, Very bright, highly visible light spot. Emitter: OBE35M-R202-SK. Receiver: OBE35M-R202-K2. Effective detection range: 0 ... 35 m. Threshold detection range: 47 m. Light source: LED. Light type: modulated visible red light. LED risk group labelling: exempt group. Transmitter frequency: F1 = 8.2 kHz. Diameter of the light spot: approx. 1200 mm at a distance of 35 m. Opening angle: 2 °. Ambient light limit: EN 60947-5-2 : 40000 Lux. MTTFd: 422 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Operation indicator: LED green: power on. Function indicator: Yellow LED:Permanently lit - light path clearPermanently off - object detectedFlashing (4 Hz) - insufficient operating reserve Flashing (8 Hz) - fault detected, the outputs maintain the status. Control elements: Receiver: light/dark switch. Control elements: Receiver: sensitivity adjustment. Operating voltage: 24 ... 240 V DC (-30 °C ≤ Tamb ≤ 60 °C) 24 ... 240 V AC (10 °C ≤ Tamb ≤ 60 °C) 30 ... 240 V AC (-30 °C ≤ Tamb ≤ 60 °C). No-load supply current: Emitter: ≤ 15 mA Receiver: ≤ 30 mA at 24 V Operating voltage. Protection class: II. Rated insulation voltageUi250 VRated impulse withstand voltageUimp2500 V: Ui. Rated insulation voltage: 250 V. Rated impulse withstand voltage: 2500 V. Power consumption: Emitter: ≤ 0.35 VA Receiver: ≤ 0.75 VA. Fuse: Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.. Switching type: The switching type of the sensor is adjustable. The default setting is: Q - BK: normally-open / dark-on /Q - GY: normally-closed / light-on C - WH: Common. Signal output: Relay, 1 alternator. Switching voltage: max. 240 V AC/DC. Switching current: max. 2.5 A , see section characteristic curve. Switching power: DC: max. 95 W AC: max. 600 VA. Usage category: DC-12 , DC-13 , AC-12 u. AC-140. Switching frequency: 25 Hz. Response time: ≤ 20 ms. Product standard: EN 60947-5-2 , EN 60947-1. UL approval: E87056 , cULus Listed. Ambient temperature: -30 ... 60 °C (-22 ... 140 °F) , cable, fixed installation -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains. Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Pollution degree: 3. Degree of protection: IP67. Connection: 2 m fixed cable. Material: . HousingPC (Polycarbonate)Optical facePMMA: . Housing: PC (Polycarbonate). Optical face: PMMA. Mass: Emitter: approx. 90 g receiver: approx. 120 g. Dimensions: . Height61.9 mmWidth20 mmDepth41.7 mm: . Height: 61.9 mm. Width: 20 mm. Depth: 41.7 mm. Cable length: 2 m
Specifications
System components
| Emitter | OBE35M-R202-SK |
| Receiver | OBE35M-R202-K2 |
General specifications
| Effective detection range | 0 ... 35 m |
| Threshold detection range | 47 m |
| Light source | LED |
| Light type | modulated visible red light |
| LED risk group labelling | exempt group |
| Transmitter frequency | F1 = 8.2 kHz |
| Diameter of the light spot | approx. 1200 mm at a distance of 35 m |
| Opening angle | 2 ° |
| Ambient light limit | EN 60947-5-2 : 40000 Lux |
Functional safety related parameters
| MTTFd | 422 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Operation indicator | LED green: power on |
| Function indicator | Yellow LED:Permanently lit - light path clearPermanently off - object detectedFlashing (4 Hz) - insufficient operating reserve Flashing (8 Hz) - fault detected, the outputs maintain the status |
| Control elements | Receiver: light/dark switch |
| Control elements | Receiver: sensitivity adjustment |
Electrical specifications
| Operating voltage | 24 ... 240 V DC (-30 °C ≤ Tamb ≤ 60 °C) 24 ... 240 V AC (10 °C ≤ Tamb ≤ 60 °C) 30 ... 240 V AC (-30 °C ≤ Tamb ≤ 60 °C) UB |
| No-load supply current | Emitter: ≤ 15 mA Receiver: ≤ 30 mA at 24 V Operating voltage I0 |
| Protection class | II |
| Rated insulation voltageUi250 VRated impulse withstand voltageUimp2500 V | Ui Rated insulation voltage |
| Rated insulation voltage | 250 V Ui |
| Rated impulse withstand voltage | 2500 V Uimp |
| Power consumption | Emitter: ≤ 0.35 VA Receiver: ≤ 0.75 VA P0 |
| Fuse | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Output
| Switching type | The switching type of the sensor is adjustable. The default setting is: Q - BK: normally-open / dark-on /Q - GY: normally-closed / light-on C - WH: Common |
| Signal output | Relay, 1 alternator |
| Switching voltage | max. 240 V AC/DC |
| Switching current | max. 2.5 A , see section characteristic curve |
| Switching power | DC: max. 95 W AC: max. 600 VA |
| Usage category | DC-12 , DC-13 , AC-12 u. AC-140 |
| Switching frequency | 25 Hz f |
| Response time | ≤ 20 ms |
Conformity
| Product standard | EN 60947-5-2 , EN 60947-1 |
Approvals and certificates
| UL approval | E87056 , cULus Listed |
Ambient conditions
| Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) , cable, fixed installation -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | 2 m fixed cable |
| Material | |
| HousingPC (Polycarbonate)Optical facePMMA | Housing |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
| Mass | Emitter: approx. 90 g receiver: approx. 120 g |
| Dimensions | |
| Height61.9 mmWidth20 mmDepth41.7 mm | Height |
| Height | 61.9 mm |
| Width | 20 mm |
| Depth | 41.7 mm |
| Cable length | 2 m |