Pepperl Fuchs ML29-P/59/103/115
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Thru-Beam Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can ML29-P/59/103/115 be shipped?
ML29-P/59/103/115 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ML29-P/59/103/115 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ML29-P/59/103/115 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ML29-P/59/103/115, subject to availability and destination.
Thru-beam sensor. Single-beam monitoring with extremely narrow sensor, Integrated circuit, Test, Simple installation - Plug & Play, Ideal for installation in door profiles or frames, Construction type(S2): Rectangular type, Test input, Light source: IRED, Light type: modulated infrared light, Operating voltage: 11 ... 30 V DC, Test input: Test: Transmitter switches off at +UB ≤ 5 V DC, Switching type: dark-on, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collector. Emitter: ML29-T/115. Receiver: ML29-R/59/103/115. Effective detection range: 0 ... 6 m. Threshold detection range: 8.5 m. Light source: IRED. Light type: modulated infrared light. Opening angle: +/- 8 °. Optical face: lateral. Ambient light limit: 40000 Lux. MTTFd: 880 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Function indicator: LED red in receiver : lights up when receiving the light beam. Operating voltage: 11 ... 30 V DC. No-load supply current: Emitter: ≤ 25 mA Receiver: ≤ 10 mA. Test input: Test: Transmitter switches off at +UB ≤ 5 V DC. Switching type: dark-on. Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collector. Switching voltage: max. 30 V DC. Switching current: max. 0.1 A. Switching frequency: 100 Hz. Response time: 5 ms. Product standard: EN 60947-5-2. Standard conformity: . StandardsEN 61000-6-2, EN 61000-6-3: . Standards: EN 61000-6-2, EN 61000-6-3. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -20 ... 75 °C (-4 ... 167 °F). Relative humidity: 90 % , noncondensing. Degree of protection: IP65. Connection: 6 m fixed cable. Material: . HousingPMMA , blackOptical facePlastic pane: . Housing: PMMA , black. Optical face: Plastic pane. Mass: per device 12 g. Dimensions: . Height85.2 mmWidth11.6 mmDepth9.2 mm: . Height: 85.2 mm. Width: 11.6 mm. Depth: 9.2 mm
Specifications
System components
| Emitter | ML29-T/115 |
| Receiver | ML29-R/59/103/115 |
General specifications
| Effective detection range | 0 ... 6 m |
| Threshold detection range | 8.5 m |
| Light source | IRED |
| Light type | modulated infrared light |
| Opening angle | +/- 8 ° |
| Optical face | lateral |
| Ambient light limit | 40000 Lux |
Functional safety related parameters
| MTTFd | 880 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Function indicator | LED red in receiver : lights up when receiving the light beam |
Electrical specifications
| Operating voltage | 11 ... 30 V DC UB |
| No-load supply current | Emitter: ≤ 25 mA Receiver: ≤ 10 mA I0 |
Input
| Test input | Test: Transmitter switches off at +UB ≤ 5 V DC |
Output
| Switching type | dark-on |
| Signal output | 1 PNP output, short-circuit protected, reverse polarity protected, open collector |
| Switching voltage | max. 30 V DC |
| Switching current | max. 0.1 A |
| Switching frequency | 100 Hz f |
| Response time | 5 ms |
Conformity
| Product standard | EN 60947-5-2 |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN 61000-6-2, EN 61000-6-3 | Standards |
| Standards | EN 61000-6-2, EN 61000-6-3 |
Approvals and certificates
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -20 ... 75 °C (-4 ... 167 °F) |
| Relative humidity | 90 % , noncondensing |
Mechanical specifications
| Degree of protection | IP65 |
| Connection | 6 m fixed cable |
| Material | |
| HousingPMMA , blackOptical facePlastic pane | Housing |
| Housing | PMMA , black |
| Optical face | Plastic pane |
| Mass | per device 12 g |
| Dimensions | |
| Height85.2 mmWidth11.6 mmDepth9.2 mm | Height |
| Height | 85.2 mm |
| Width | 11.6 mm |
| Depth | 9.2 mm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G