Pepperl Fuchs ML100-8-HGU-100-RT/95/102/162 – Convergent beam sensor. Convergent mode sensor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Diffuse Mode Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can ML100-8-HGU-100-RT/95/102/162 be shipped?
ML100-8-HGU-100-RT/95/102/162 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ML100-8-HGU-100-RT/95/102/162 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ML100-8-HGU-100-RT/95/102/162 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ML100-8-HGU-100-RT/95/102/162, subject to availability and destination.
Convergent beam sensor. Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mounting. Detection range: 10 ... 100 mm. Adjustment range: 30 ... 100 mm. Reference target: standard black, 100 mm x 100 mm. Light source: LED. Light type: modulated visible red light. Polarization filter: no. Diameter of the light spot: approx. 6 mm x 60 mm at 100 mm. Opening angle: Emitter: 3.5 ° vertical ; 30 ° horizontal. Optical face: frontal. Ambient light limit: EN 60947-5-2:2007+A1:2012. MTTFd: 860 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Operation indicator: LED green: power on. Function indicator: LED yellow: lights when object is detected. Control elements: Sensing range adjuster. Control elements: Light-on/dark-on changeover switch. Operating voltage: 10 ... 30 V DC. Ripple: max. 10 %. No-load supply current: < 20 mA. Switching type: The switching type of the sensor is adjustable. The default setting is: light-on. Signal output: 1 NPN output, short-circuit protected, reverse polarity protected, open collector. Switching voltage: max. 30 V DC. Switching current: max. 100 mA , resistive load. Voltage drop: ≤ 1.5 V DC. Switching frequency: 500 Hz. Response time: 1 ms. Product standard: EN 60947-5-2. UL approval: cULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -30 ... 60 °C (-22 ... 140 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP67. Connection: Connector M8 x 1 , 4-pin. Material: . HousingPC (Polycarbonate)Optical facePMMA: . Housing: PC (Polycarbonate). Optical face: PMMA. Mass: approx. 10 g. Tightening torque, fastening screws: 0.6 Nm. Dimensions: . Height31 mmWidth11 mmDepth20 mm: . Height: 31 mm. Width: 11 mm. Depth: 20 mm
Specifications
General specifications
| Detection range | 10 ... 100 mm |
| Adjustment range | 30 ... 100 mm |
| Reference target | standard black, 100 mm x 100 mm |
| Light source | LED |
| Light type | modulated visible red light |
| Polarization filter | no |
| Diameter of the light spot | approx. 6 mm x 60 mm at 100 mm |
| Opening angle | Emitter: 3.5 ° vertical ; 30 ° horizontal |
| Optical face | frontal |
| Ambient light limit | EN 60947-5-2:2007+A1:2012 |
Functional safety related parameters
| MTTFd | 860 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Operation indicator | LED green: power on |
| Function indicator | LED yellow: lights when object is detected |
| Control elements | Sensing range adjuster |
| Control elements | Light-on/dark-on changeover switch |
Electrical specifications
| Operating voltage | 10 ... 30 V DC UB |
| Ripple | max. 10 % |
| No-load supply current | < 20 mA I0 |
Output
| Switching type | The switching type of the sensor is adjustable. The default setting is: light-on |
| Signal output | 1 NPN output, short-circuit protected, reverse polarity protected, open collector |
| Switching voltage | max. 30 V DC |
| Switching current | max. 100 mA , resistive load |
| Voltage drop | ≤ 1.5 V DC Ud |
| Switching frequency | 500 Hz f |
| Response time | 1 ms |
Conformity
| Product standard | EN 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | Connector M8 x 1 , 4-pin |
| Material | |
| HousingPC (Polycarbonate)Optical facePMMA | Housing |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
| Mass | approx. 10 g |
| Tightening torque, fastening screws | 0.6 Nm |
| Dimensions | |
| Height31 mmWidth11 mmDepth20 mm | Height |
| Height | 31 mm |
| Width | 11 mm |
| Depth | 20 mm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs ML100-8-HGU-100-IR/95/102/162 – Convergent beam sensor. Convergent mode sensor
Available on requestPepperl Fuchs ML100-8-HGU-100-IR/95/103/162 – Convergent beam sensor. Convergent mode sensor
Available on requestPepperl Fuchs ML100-8-HGU-100-RT/102/115/162 – Convergent beam sensor. Convergent mode sensor
Available on requestPepperl Fuchs ML100-8-HGU-100-RT/103/115/162 – Convergent beam sensor. Convergent mode sensor
Available on requestPepperl Fuchs ML100-8-HGU-100-RT/95/103/162 – Convergent beam sensor. Convergent mode sensor
Available on requestPepperl Fuchs ML100-8-HW-350-RT/102/115 – Triangulation sensor (BGE). Diffuse mode sensor for…
Available on requestPepperl Fuchs ML100-8-HW-350-RT/103/115 – Triangulation sensor (BGE). Diffuse mode sensor for…
Available on requestPepperl Fuchs ML100-8-HW-350-RT/95/102 – Triangulation sensor (BGE). Diffuse mode sensor for…