Pepperl Fuchs MB-FB-GTR1*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Segment Coupler for PROFIBUS PA |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can MB-FB-GTR1* be shipped?
MB-FB-GTR1* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MB-FB-GTR1* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MB-FB-GTR1* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MB-FB-GTR1*, subject to availability and destination.
Power Hub Motherboard. Power hub motherboard for protocol gateways modules, For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area<BR>Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Division 2 - high-power trunk<BR>Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 ... 35 V SELV/PELV. Rated current: 2 ... 3 A. Fault signal: VFC alarm output via connectors. Rotary switch: bus addressing, gateway-specific. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Housing material: Polycarbonate. Degree of protection: IP20. Mass: approx. 300 g. Mounting: DIN rail mounting. Certificate: TÜV 15 ATEX 7735 X. Marking II 3 G Ex ec IIC T4 Gc: . Marking: II 3 G Ex ec IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018. IECEx approval: IECEx TUR 16.0007X. Approved forEx ec IIC T4 Gc: . Approved for: Ex ec IIC T4 Gc. Marine approval: pending. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Motherboard based |
| Installation in hazardous area | Zone 2 / Div. 2 |
Supply
| Rated voltage | 19.2 ... 35 V SELV/PELV Ur |
| Rated current | 2 ... 3 A Ir |
Indicators/operating means
| Fault signal | VFC alarm output via connectors |
| Rotary switch | bus addressing, gateway-specific |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Pollution degree | max. 2, according to IEC 60664 |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | approx. 300 g |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| Certificate | TÜV 15 ATEX 7735 X |
| Marking II 3 G Ex ec IIC T4 Gc | Marking |
| Marking | II 3 G Ex ec IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 |
International approvals
| IECEx approval | IECEx TUR 16.0007X |
| Approved forEx ec IIC T4 Gc | Approved for |
| Approved for | Ex ec IIC T4 Gc |
Certificates and approvals
| Marine approval | pending |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G