Available on request

Pepperl Fuchs LUC-M40

MPN: LUC-M40 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryUltrasonic Level Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can LUC-M40 be shipped?

LUC-M40 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LUC-M40 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LUC-M40 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LUC-M40, subject to availability and destination.

Ultrasonic Level Sensor. Device for non-contact level measurement, Measuring range up to 10 m in fluids, Measuring range up to 5 m in bulk materials, Quick and simple commissioning via menu-guided onsite operation with four-line display, Optional remote display and operation (up to 20 m from transmitter), Integrated temperature sensor for automatic correction of the temperature dependent sound velocity. Measuring method: The sensor of the device transmits ultrasonic pulses in the direction of the product surface. There, the ultrasonic pulses are reflected back and received by the sensor. The device measures the time between pulse transmission and reception. The instrument uses the time (and the velocity of sound) to calculate the distance between the sensor membrane and the product surface. As the device knows the empty distance from a user entry, the device calculate the level.. Equipment architecture: 4 ... 20 mA output with HART protocol. Construction type: compact device. Series: LUC-M40. Connection: 2-wire , 4 ... 20 mA , HART protocol , 14 ... 30 V DC. Rated voltage: 14 ... 30 V DC , 8 V DC at 20 mA. Ripple: 47 ... 125 Hz , Upp = 200 mV (measured at 500 Ω). Noise: 0.5 ... 10 kHz , Urms = 2.2 mV (measured at 500 Ω). Current consumption: 3.6 ... 22 mA. Power consumption: 51 ... 800 mW. Measured variable: distance between the sensor membrane and the product surfaceusing the linearization function, the device calculate- level in any units- volume in any units- flow across measuring weirs or open channels in any units. Measuring range: max. 10 m (32.8 foot) in fluidsmax. 5 m (16.4 foot) in bulk materials. Operating frequency: approx. 42 kHz. Blocking distance: 0.4 m. Load: min. 250 Ω for HART communication. Linearity: The linearization function of the device allows conversion of the measured value into any unit of length or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow from the measured level).. Output signal: 4 ... 20 mA with HART protocol. Output damping: 0 ... 255 s , freely selectable. Signal on alarm: error information can be accessed via the following interfaces:- on-site display (error symbol, error code and plain text description)- current output (configurable)- digital interface. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006: . Directive 2014/30/EU: EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006. Low voltage: . Directive 2014/35/EUEN 61010-1:2001: . Directive 2014/35/EU: EN 61010-1:2001. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529:2001. Vibration resistance: EN 60068-2-64. Climate class: EN 60068-2-38 (test Z/AD) DIN/IEC 68 T2-30Db. Resistance to alternating temperature cycles: EN 60068-2-14. Reaction time: min. 2 s. Reference operating conditions: temperature = 20 °C (68 °F)pressure = 1013 mbarabshumidity = 50 %ideal reflective surface (e. g. calm, smooth fluid surface)no interference reflections within signal beamset application parameters:- tank shape = flat ceiling- medium property = liquid- process conditions = calm surface. Measured value resolution: 2 mm. Measuring frequency: max. 0.5 Hz. Maximum measured error: typical specifications for reference operating conditions (include linearity, repeatability, and hysteresis): ± 4 mm (0.16 inch) or 0.2% of set measuring range (empty calibration)1)1)whichever is greater. Installation conditions: see technical information (TI). Ambient conditions: . Resistance to alternating temperature cyclesNb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cyclesVibration resistance20 ... 2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min: . Resistance to alternating temperature cycles: Nb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cycles. Vibration resistance: 20 ... 2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min. Process conditions: . Process temperature-40 ... 80 °C (-40 ... 176 °F)Process pressure (static pressure)0.7 ... 2.5 bar (10.2 ... 36.3 psi) , absolute pressure: . Process temperature: -40 ... 80 °C (-40 ... 176 °F). Process pressure (static pressure): 0.7 ... 2.5 bar (10.2 ... 36.3 psi) , absolute pressure. Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) see technical information (TI). Storage temperature: -40 ... 80 °C (-40 ... 176 °F). Degree of protection: with closed housing, tested according to- IP68, NEMA 6P (24 h at 1.83 m under water surface)- IP66, NEMA 4Xwith open housing: IP20, NEMA 1 (also ingress protection of the display). Connection: cable gland M20x1.5cable gland NPT1/2cable gland G1/2. Material: material in contact with process: sensor PVDF, seal Viton or EPDM, flange PP, PVDF or stainless steel 1.4535/316L housing: aluminum, seawater resistant, chromated, powder-coatedcover:- aluminum, for version without on-site display- inspection glass for version with on-site display. Mass: 3 kg. Dimensions: see section dimensions. Process connection: - cylindrical thread G1-1/2B, G2B to DIN/ISO 228/1- conical thread NPT1-1/2, NPT2 to ANSI B 1.20.1- flanges to EN 1092-1 from DN80, to ANSI B 16.5 from 3 inch, to JIS B 2238 (RF) from DN80- mounting bracket LUC-Z17. EU-type examination certificate: see instruction manuals. Construction type: housing design:- F12 housing with sealed terminal compartment for standard or EEx ia applications- T12 housing with separate terminal compartment and flameproof encapsulationcover:- version without on-site display- version with on-site display (transparent cover), this version cannot be supplied together with the ATEX II 1/2D certificate. Display elements: display and operating module LUC-Z15 at the device. Control elements: on-site operation:- via 3 keys of the display and operating module- via handheld terminalremote control:- operation with operating program (for communication variant HART). Supplementary documentation: technical information (TI) manuals, brief instructions (BA, KA) instruction manuals control drawings (ZD). Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.. Designation: - LUC-Z17, mounting bracket - LUC-Z3*, mounting frame- LUC-Z5*, wall bracket - LUC-Z15, display and operating module for on-site operation- LUC-Z16, weather protection cover

Specifications

General specifications

Measuring methodThe sensor of the device transmits ultrasonic pulses in the direction of the product surface. There, the ultrasonic pulses are reflected back and received by the sensor. The device measures the time between pulse transmission and reception. The instrument uses the time (and the velocity of sound) to calculate the distance between the sensor membrane and the product surface. As the device knows the empty distance from a user entry, the device calculate the level.
Equipment architecture4 ... 20 mA output with HART protocol
Construction typecompact device
SeriesLUC-M40

Supply

Connection2-wire , 4 ... 20 mA , HART protocol , 14 ... 30 V DC
Rated voltage14 ... 30 V DC , 8 V DC at 20 mA Ur
Ripple47 ... 125 Hz , Upp = 200 mV (measured at 500 Ω)
Noise0.5 ... 10 kHz , Urms = 2.2 mV (measured at 500 Ω)
Current consumption3.6 ... 22 mA
Power consumption51 ... 800 mW

Input

Measured variabledistance between the sensor membrane and the product surfaceusing the linearization function, the device calculate- level in any units- volume in any units- flow across measuring weirs or open channels in any units
Measuring rangemax. 10 m (32.8 foot) in fluidsmax. 5 m (16.4 foot) in bulk materials
Operating frequencyapprox. 42 kHz
Blocking distance0.4 m

Output

Loadmin. 250 Ω for HART communication
LinearityThe linearization function of the device allows conversion of the measured value into any unit of length or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow from the measured level).
Output signal4 ... 20 mA with HART protocol
Output damping0 ... 255 s , freely selectable
Signal on alarmerror information can be accessed via the following interfaces:- on-site display (error symbol, error code and plain text description)- current output (configurable)- digital interface

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006
Low voltage
Directive 2014/35/EUEN 61010-1:2001 Directive 2014/35/EU
Directive 2014/35/EUEN 61010-1:2001

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529:2001
Vibration resistanceEN 60068-2-64
Climate classEN 60068-2-38 (test Z/AD) DIN/IEC 68 T2-30Db
Resistance to alternating temperature cyclesEN 60068-2-14

Measurement accuracy

Reaction timemin. 2 s
Reference operating conditionstemperature = 20 °C (68 °F)pressure = 1013 mbarabshumidity = 50 %ideal reflective surface (e. g. calm, smooth fluid surface)no interference reflections within signal beamset application parameters:- tank shape = flat ceiling- medium property = liquid- process conditions = calm surface
Measured value resolution2 mm
Measuring frequencymax. 0.5 Hz
Maximum measured errortypical specifications for reference operating conditions (include linearity, repeatability, and hysteresis): ± 4 mm (0.16 inch) or 0.2% of set measuring range (empty calibration)1)1)whichever is greater

Operating conditions

Installation conditionssee technical information (TI)
Ambient conditions
Resistance to alternating temperature cyclesNb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cyclesVibration resistance20 ... 2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min Resistance to alternating temperature cycles
Resistance to alternating temperature cyclesNb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cycles
Vibration resistance20 ... 2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min
Process conditions
Process temperature-40 ... 80 °C (-40 ... 176 °F)Process pressure (static pressure)0.7 ... 2.5 bar (10.2 ... 36.3 psi) , absolute pressure Process temperature
Process temperature-40 ... 80 °C (-40 ... 176 °F)
Process pressure (static pressure)0.7 ... 2.5 bar (10.2 ... 36.3 psi) , absolute pressure

Ambient conditions

Ambient temperature-40 ... 80 °C (-40 ... 176 °F) see technical information (TI)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)

Mechanical specifications

Degree of protectionwith closed housing, tested according to- IP68, NEMA 6P (24 h at 1.83 m under water surface)- IP66, NEMA 4Xwith open housing: IP20, NEMA 1 (also ingress protection of the display)
Connectioncable gland M20x1.5cable gland NPT1/2cable gland G1/2
Materialmaterial in contact with process: sensor PVDF, seal Viton or EPDM, flange PP, PVDF or stainless steel 1.4535/316L housing: aluminum, seawater resistant, chromated, powder-coatedcover:- aluminum, for version without on-site display- inspection glass for version with on-site display
Mass3 kg
Dimensionssee section dimensions
Process connection- cylindrical thread G1-1/2B, G2B to DIN/ISO 228/1- conical thread NPT1-1/2, NPT2 to ANSI B 1.20.1- flanges to EN 1092-1 from DN80, to ANSI B 16.5 from 3 inch, to JIS B 2238 (RF) from DN80- mounting bracket LUC-Z17

Data for application in connection with hazardous areas

EU-type examination certificatesee instruction manuals

Mechanical construction

Construction typehousing design:- F12 housing with sealed terminal compartment for standard or EEx ia applications- T12 housing with separate terminal compartment and flameproof encapsulationcover:- version without on-site display- version with on-site display (transparent cover), this version cannot be supplied together with the ATEX II 1/2D certificate

Indication and operation

Display elementsdisplay and operating module LUC-Z15 at the device
Control elementson-site operation:- via 3 keys of the display and operating module- via handheld terminalremote control:- operation with operating program (for communication variant HART)

General information

Supplementary documentationtechnical information (TI) manuals, brief instructions (BA, KA) instruction manuals control drawings (ZD)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Accessories

Designation- LUC-Z17, mounting bracket - LUC-Z3*, mounting frame- LUC-Z5*, wall bracket - LUC-Z15, display and operating module for on-site operation- LUC-Z16, weather protection cover
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote