Pepperl Fuchs LMC-Ex
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Magnetic Immersion Probes |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LMC-Ex be shipped?
LMC-Ex is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LMC-Ex in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LMC-Ex and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LMC-Ex, subject to availability and destination.
Magnetic Immersion Probe for Continuous Measurement. Sensor for continuous level measurement in liquids, Resolution 5 mm or 15 mm, Media contacting parts of stainless steel, Mounting without removing the float , Approved for zone 0. Equipment architecture: A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1.. Series: LMC-Ex. Connection: version I: 2-wire, 4 ... 20 mAversion O4: 3-wire, potentiometer connection approx. 40 kΩ. Electromagnetic compatibility: . Directive 2014/30/EUEN 61000-6-2:2006 , EN 61000-6-4:2011: . Directive 2014/30/EU: EN 61000-6-2:2006 , EN 61000-6-4:2011. Degree of protection: IEC 60529:2000. Accuracy: resolution:- version LMC5: 5 mm- version LMC15: 15 mm. Process conditions: . Process temperature-20 ... 100 °C (-4 ... 212 °F)Process pressure (static pressure)≤ 16 bar (232.1 psi)Densityversion S1: ≥ 0.6 g/cm3version S2: ≥ 0.8 g/cm3version S3: ≥ 0.7 g/cm3: . Process temperature: -20 ... 100 °C (-4 ... 212 °F). Process pressure (static pressure): ≤ 16 bar (232.1 psi). Density: version S1: ≥ 0.6 g/cm3version S2: ≥ 0.8 g/cm3version S3: ≥ 0.7 g/cm3. Ambient temperature: terminal box: -50 ... 60 °C (-58 ... 140 °F). Degree of protection: IP66 / IP68. Connection: Version I: 2 terminals, max. 2.5 mm2Version O4: 3 terminals, max. 2.5 mm2. Material: float, guide tube, process connection: stainless steel 1.4571/316Titerminal box: aluminum die-casting. Dimensions: float:- version S1: ball ∅80 mm- version S2: cylinder ∅44 mm x 52 mm- version S3: ball ∅52 mmguide tube:- version LMC5: ∅14 mm, max. length 3000 mm- version LMC15: ∅12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm. Process connection: thread G1-1/2A, G2A to DIN/ISO 228/1. EU-type examination certificate: KEMA 03 ATEX 1497 X. Marking II 1/2G EEx ia IIC T4...T6VoltageUi28 VCurrentIi120 mAInternal capacitanceCi0 nFInternal inductanceLi 0 µH: . Marking: II 1/2G EEx ia IIC T4...T6. Voltage: 28 V. Current: 120 mA. Internal capacitance: 0 nF. Internal inductance: 0 µH. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007: . Directive 2014/34/EU: EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007. Supplementary documentation: instruction manuals (SI). Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.. Designation: - LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti- LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti- LML-FS5 float, ball, Ø52 mm, Titanium- LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti
Specifications
General specifications
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1. |
| Series | LMC-Ex |
Output
| Connection | version I: 2-wire, 4 ... 20 mAversion O4: 3-wire, potentiometer connection approx. 40 kΩ |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61000-6-2:2006 , EN 61000-6-4:2011 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 |
Conformity
| Degree of protection | IEC 60529:2000 |
Measurement accuracy
| Accuracy | resolution:- version LMC5: 5 mm- version LMC15: 15 mm |
Operating conditions
| Process conditions | |
| Process temperature-20 ... 100 °C (-4 ... 212 °F)Process pressure (static pressure)≤ 16 bar (232.1 psi)Densityversion S1: ≥ 0.6 g/cm3version S2: ≥ 0.8 g/cm3version S3: ≥ 0.7 g/cm3 | Process temperature |
| Process temperature | -20 ... 100 °C (-4 ... 212 °F) |
| Process pressure (static pressure) | ≤ 16 bar (232.1 psi) |
| Density | version S1: ≥ 0.6 g/cm3version S2: ≥ 0.8 g/cm3version S3: ≥ 0.7 g/cm3 |
Ambient conditions
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP66 / IP68 |
| Connection | Version I: 2 terminals, max. 2.5 mm2Version O4: 3 terminals, max. 2.5 mm2 |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Titerminal box: aluminum die-casting |
| Dimensions | float:- version S1: ball ∅80 mm- version S2: cylinder ∅44 mm x 52 mm- version S3: ball ∅52 mmguide tube:- version LMC5: ∅14 mm, max. length 3000 mm- version LMC15: ∅12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 |
Data for application in connection with hazardous areas
| EU-type examination certificate | KEMA 03 ATEX 1497 X |
| Marking II 1/2G EEx ia IIC T4...T6VoltageUi28 VCurrentIi120 mAInternal capacitanceCi0 nFInternal inductanceLi 0 µH | Marking |
| Marking | II 1/2G EEx ia IIC T4...T6 |
| Voltage | 28 V Ui |
| Current | 120 mA Ii |
| Internal capacitance | 0 nF Ci |
| Internal inductance | 0 µH Li |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 |
General information
| Supplementary documentation | instruction manuals (SI) |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Accessories
| Designation | - LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti- LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti- LML-FS5 float, ball, Ø52 mm, Titanium- LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G