Pepperl Fuchs LFL2-BK-U-TPK5-EMS
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Float Switches |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LFL2-BK-U-TPK5-EMS be shipped?
LFL2-BK-U-TPK5-EMS is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LFL2-BK-U-TPK5-EMS in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LFL2-BK-U-TPK5-EMS and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LFL2-BK-U-TPK5-EMS, subject to availability and destination.
Float Switch. Switch element: microswitch, <b>mercury-free</b>, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2017: . Directive 2014/35/EU: EN 60947-5-1:2017. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for many acids and lyes mounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for many acids and lyes mounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3: . Process pressure (static pressure): ≤ 2 bar (29 psi) at 20 °C (68 °F). Density: ≥ 0.6 g/cm3. Ambient temperature: 5 ... 70 °C (41 ... 158 °F). Storage temperature: -25 ... 70 °C (-13 ... 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene) cable: TPK (3 x 0.75 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Series | LFL2-**-U |
| Construction type | ball design |
Electrical specifications
| Contact loading | 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load |
| Rated insulation voltage | 300 V |
| Pulse withstand voltage | 4 kV |
| Electrical life | ≥ 5 x 104 switching cycles |
Directive conformity
| Low voltage | |
| Directive 2014/35/EUEN 60947-5-1:2017 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 60947-5-1:2017 |
Conformity
| Degree of protection | IEC 60529:2001 |
Application
| Description | microswitch with switching ball, change-over contact |
Function and system design
| Equipment architecture | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. |
Approvals and certificates
| CCC approval | Certified by China Compulsory Certification (CCC) |
Operating conditions
| Installation conditions | |
| Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for many acids and lyes mounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal. | Installation instructions |
| Installation instructions | range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for many acids and lyes mounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal. |
| Process conditions | |
| Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3 | Process pressure (static pressure) |
| Process pressure (static pressure) | ≤ 2 bar (29 psi) at 20 °C (68 °F) |
| Density | ≥ 0.6 g/cm3 |
Ambient conditions
| Ambient temperature | 5 ... 70 °C (41 ... 158 °F) |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Altitude | ≤ 2000 m above MSL |
Mechanical specifications
| Degree of protection | IP68 |
| Cable | |
| LengthL5 m | L Length |
| Length | 5 m L |
Mechanical construction
| Material | float: PP (Polypropylene) cable: TPK (3 x 0.75 mm2) |
| Switching point | switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6° |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G