Pepperl Fuchs LB6016E
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB6016E be shipped?
LB6016E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB6016E in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB6016E and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB6016E, subject to availability and destination.
Digital Output with Shutdown Input. 2-channel, Outputs Ex ic, Installation in Zone 2 or safe area, Line fault detection switched on and off, Explosion protection: Ex ic. Occupied slots: 1. Connection: backplane bus. Rated voltage: Use only in connection with the power supplies LB9***. Power dissipation: 1.95 W. Power consumption: 2.9 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 2. Suitable field devices: . Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm: . Field device: Solenoid Valve. Field device [2]: audible alarm. Field device [3]: visual alarm. Connection: channel I: 1+, 4/5/6/8-; channel II: 7+, 4/5/6/8-. Internal resistor: 258 Ω , both channels parallel 129 Ω. Current limit: 40 mA both channels parallel 80 mA. Open loop voltage: 23 V , both channels parallel 23 V. Line fault detection: can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms). Short-circuit< 50 ΩOpen-circuit> 10 kΩ: . Short-circuit: < 50 Ω. Open-circuit: > 10 kΩ. Response time: 10 ms (depending on bus cycle time). Watchdog: within 0.5 s the device goes in safe state, e.g. after loss of communication. LED indication: Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1, 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Mode LED (M) white: Parallel operation of outputs. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Altitude: max. 2000 m. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 when mounted on backplane. Connection: removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2). Mass: approx. 150 g. Dimensions: . Height100 mmWidth16 mmDepth102 mm: . Height: 100 mm. Width: 16 mm. Depth: 102 mm. EU-type examination certificate: EXA 16 ATEX 0035X. Marking II 3 G Ex nA [ic] IIC T4 Gc: . Marking: II 3 G Ex nA [ic] IIC T4 Gc. Output: . VoltageUo24.2 VCurrentIo108 mAPowerPo654 mWInternal capacitanceCi12 nFInternal inductanceLi0 mH: Uo. Voltage: 24.2 V. Current: 108 mA. Power: 654 mW. Internal capacitance: 12 nF. Internal inductance: 0 mH. Output (both channels parallel): . VoltageUo24.2 VCurrentIo216 mAPowerPo1307 mWInternal capacitanceCi24 nFInternal inductanceLi0 mH: Uo. Voltage: 24.2 V. Current: 216 mA. Power: 1307 mW. Internal capacitance: 24 nF. Internal inductance: 0 mH. Galvanic isolation: . Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V: . Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010. ATEX approval: EXA 16 ATEX 0035X. IECEx approval: IECEx EXA 16.0010X. Approved forEx nA [ic] IIC T4 Gc: . Approved for: Ex nA [ic] IIC T4 Gc. System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Slots
| Occupied slots | 1 |
Supply
| Connection | backplane bus |
| Rated voltage | Use only in connection with the power supplies LB9*** Ur |
| Power dissipation | 1.95 W |
| Power consumption | 2.9 W |
Internal bus
| Connection | backplane bus |
| Interface | manufacturer-specific bus to standard com unit |
Digital output
| Number of channels | 2 |
| Suitable field devices | |
| Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm | Field device |
| Field device | Solenoid Valve |
| Field device [2] | audible alarm |
| Field device [3] | visual alarm |
| Connection | channel I: 1+, 4/5/6/8-; channel II: 7+, 4/5/6/8- |
| Internal resistor | 258 Ω , both channels parallel 129 Ω Ri |
| Current limit | 40 mA both channels parallel 80 mA Imax |
| Open loop voltage | 23 V , both channels parallel 23 V Us |
| Line fault detection | can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) |
| Short-circuit< 50 ΩOpen-circuit> 10 kΩ | Short-circuit |
| Short-circuit | < 50 Ω |
| Open-circuit | > 10 kΩ |
| Response time | 10 ms (depending on bus cycle time) |
| Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Indicators/settings
| LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1, 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Mode LED (M) white: Parallel operation of outputs |
| Coding | optional mechanical coding via front socket |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Altitude | max. 2000 m |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 when mounted on backplane |
| Connection | removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
| Mass | approx. 150 g |
| Dimensions | |
| Height100 mmWidth16 mmDepth102 mm | Height |
| Height | 100 mm |
| Width | 16 mm |
| Depth | 102 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | EXA 16 ATEX 0035X |
| Marking II 3 G Ex nA [ic] IIC T4 Gc | Marking |
| Marking | II 3 G Ex nA [ic] IIC T4 Gc |
| Output | |
| VoltageUo24.2 VCurrentIo108 mAPowerPo654 mWInternal capacitanceCi12 nFInternal inductanceLi0 mH | Uo Voltage |
| Voltage | 24.2 V Uo |
| Current | 108 mA Io |
| Power | 654 mW Po |
| Internal capacitance | 12 nF Ci |
| Internal inductance | 0 mH Li |
| Output (both channels parallel) | |
| VoltageUo24.2 VCurrentIo216 mAPowerPo1307 mWInternal capacitanceCi24 nFInternal inductanceLi0 mH | Uo Voltage |
| Voltage | 24.2 V Uo |
| Current | 216 mA Io |
| Power | 1307 mW Po |
| Internal capacitance | 24 nF Ci |
| Internal inductance | 0 mH Li |
| Galvanic isolation | |
| Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | Output/power supply, internal bus |
| Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010 |
International approvals
| ATEX approval | EXA 16 ATEX 0035X |
| IECEx approval | IECEx EXA 16.0010X |
| Approved forEx nA [ic] IIC T4 Gc | Approved for |
| Approved for | Ex nA [ic] IIC T4 Gc |
General information
| System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G